Plan Review Stops For Permit 21041634 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2021-07-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-07-29 |
Time |
07:25 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-07-29 |
Time |
07:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-09-17 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-09-17 |
Time |
07:49 |
Sent To |
|
|
Notes |
2021-09-17 07:58:28 | | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | APPROVAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-07-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-07-29 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-07-29 |
Time |
07:23 |
Sent To |
|
|
Notes |
2021-07-29 07:36:11 | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561?805?6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, PLEASE PROVIDE ALL DETAILS INCLUDING | | STRUCTURAL AND FIRE RATINGS FOR INFILL CONSTRUCTION AND | | KITCHEN/BATHROOM WORK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-05-24 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-05-24 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-05-21 |
Time |
06:28 |
Sent To |
|
|
Notes |
2021-05-24 08:26:14 | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, PLEASE PROVIDE ALL DETAILS INCLUDING | | STRUCTURAL AND FIRE RATINGS FOR INFILL CONSTRUCTION AND | | KITCHEN/BATHROOM WORK. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-05-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-05-24 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-05-24 |
Time |
12:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-09-17 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-09-17 |
Time |
10:13 |
Sent To |
|
|
Notes |
2021-09-17 10:42:26 | NO FIRE SPRINKLER PLAN NOR PAPERWORK FOUND AS NOTED ON | | COVER PAGE | | | | ANY WORK ON THE FIRE SPRINKLER SYSTEM, INCLUDING DEMO, | | SHALL BE DONE UNDERSEPARATE PERMIT & SHOP DRAWINGS | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2021-07-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-07-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-07-06 |
Time |
14:06 |
Sent To |
|
|
Notes |
2021-07-06 14:14:25 | NO FIRE SPRINKLER PLAN NOR PAPERWORK FOUND AS NOTED ON | | COVER PAGE | | | | ANY WORK ON THE FIRE SPRINKLER SYSTEM, INCLUDING DEMO, | | SHALL BE DONE UNDERSEPARATE PERMIT & SHOP DRAWINGS | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2021-05-24 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-05-24 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-05-24 |
Time |
15:25 |
Sent To |
|
|
Notes |
2021-05-24 15:25:39 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | THERE ARE INDICATIONS A MULTIPLE WALLS BEING REMOVED | | WITH NEW SPACES CREATED. THE BUILDING HAS AN EXISTING | | FIRE SPRINKLER AND FIRE ALARM SYSTEM. | | | | THERE IS NO INDICATION OF FIRE SPRINKLER NOR FIRE ALARM | | WORK. | | | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR | | FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED | | CONTRACTORS FOR CODE COVERAGE COMPLIANCE. | | | | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT. | | | | | | 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE | | SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER | | SEPARATE PERMITS AND SHOP DRAWINGS. | | | | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT. | | | | | | 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR | | FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE | | THROUGHOUT THE CONSTRUCTION PERIOD, INCLUDING DEMO. | | | | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT. | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-09-21 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-09-21 |
Time |
18:46 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-09-16 |
Time |
12:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-07-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-07-29 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-07-01 |
Time |
08:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-05-24 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-05-24 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-05-07 |
Time |
10:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2021-09-21 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-09-21 |
Time |
18:45 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-09-21 |
Time |
18:45 |
Sent To |
|
|
Notes |
2021-09-21 18:46:20 | 09/21/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2021-07-13 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-07-13 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-07-13 |
Time |
14:26 |
Sent To |
|
|
Notes |
2021-07-13 14:27:32 | 07/13/21 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | SECOND REQUEST, NON OF THE COMMENTS WHERE ADDRES! | | | | 1. UNIT 106 HAS A BUSINESS TAX FOR A FITNESS STUDIO. | | PLEASE PROVIDE INFORMATION AND PLANS CORRESPONDING TO | | THE TYPE OF OCCUPANCY AND ACCESSIBILITY PER THE WPB | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. | | | | 2. ON SHEET A-2; | | | | A. PLEASE PROVIDE A PLUMBING RISER DIAGRAM FOR THE | | BATHROOM AND WASHING MACHINE PER THE WPB AMENDMENTS TO | | THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING. | | | | B. PLEASE GIVE THE NUMBER OF OCCUPANTS NUMBER, TYPE, | | AND CALCIFICATION TO DETERMINE THE MINIMUM FIXTURES. | | | | 3. THE PLANS SHOW A STACKABLE UNIT. IF THIS IS A | | COMMERCIAL UNIT, IT WILL NEED A LINT TRAP AT THE | | WASHING MACHINE; PLEASE PROVIDE THE SPECIFICATION AND | | SHOW IT ON ISOMETRIC PER THE 2020 FC SEC P 1003.6 | | CLOTHES WASHER DISCHARGE INTERCEPTOR. | | | | 4. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE | | ACCESSIBLE WITHOUT MOVING THE UNIT WITHIN REACH PER THE | | 2020 FBC SEC. P 606.3 ACCESS TO VALVES. | | | | 5. PLEASE SHOW DIMENSION BETWEEN FIXTURES INSTALLATION | | TO CONFORM TO THE 2020 FBC SEC. P 405.3.1 WATER CLOSET, | | LAV AND P 421.4. SHOWER. | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2021-07-13 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-07-13 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-07-13 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-05-24 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-05-24 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-05-24 |
Time |
07:32 |
Sent To |
|
|
Notes |
2021-05-24 11:32:08 | 05/24/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. UNIT 106 HAS A BUSINESS TAX FOR A FITNESS STUDIO. | | PLEASE PROVIDE INFORMATION AND PLANS CORRESPONDING TO | | THE TYPE OF OCCUPANCY AND ACCESSIBILITY PER THE WPB | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. | | | | 2. ON SHEET A-2; | | | | A. PLEASE PROVIDE A PLUMBING RISER DIAGRAM FOR THE | | BATHROOM AND WASHING MACHINE PER THE WPB AMENDMENTS TO | | THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING. | | | | B. PLEASE GIVE THE NUMBER OF OCCUPANTS NUMBER, TYPE, | | AND CALCIFICATION TO DETERMINE THE MINIMUM FIXTURES. | | | | 3. THE PLANS SHOW A STACKABLE UNIT. IF THIS IS A | | COMMERCIAL UNIT, IT WILL NEED A LINT TRAP AT THE | | WASHING MACHINE; PLEASE PROVIDE THE SPECIFICATION AND | | SHOW IT ON ISOMETRIC PER THE 2020 FC SEC P 1003.6 | | CLOTHES WASHER DISCHARGE INTERCEPTOR. | | | | 4. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE | | ACCESSIBLE WITHOUT MOVING THE UNIT WITHIN REACH PER THE | | 2020 FBC SEC. P 606.3 ACCESS TO VALVES. | | | | 5. PLEASE SHOW DIMENSION BETWEEN FIXTURES INSTALLATION | | TO CONFORM TO THE 2020 FBC SEC. P 405.3.1 WATER CLOSET, | | LAV AND P 421.4. SHOWER. | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
N |
Date |
2021-09-17 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-09-17 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-09-17 |
Time |
07:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-07-01 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-07-01 |
Time |
17:06 |
Sent To |
|
|
Notes |
2021-07-01 17:08:16 | ORIGINAL SIGNED AND SEALED DOCUMENTS ROUTED TO | | STORAGE.ME |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-05-07 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-05-07 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-05-07 |
Time |
14:06 |
Sent To |
|
|
Notes |
2021-05-07 14:07:39 | ORIGINAL SIGNED AND SEALED DOCUMENTS ROUTED TO | | STORAGE.ME |
|
|