Plan Review Details - Permit 21041631
Plan Review Stops For Permit 21041631
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2021-07-19 Cont ID  
Sent By pvalenti Date 2021-07-19 Time 14:09 Rev Time 0.00
Received By pvalenti Date 2021-07-19 Time 14:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-08-05 Cont ID  
Sent By pvalenti Date 2021-08-05 Time 07:18 Rev Time 0.00
Received By pvalenti Date 2021-08-05 Time 07:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-08-03 Cont ID  
Sent By pvalenti Date 2021-08-03 Time 11:01 Rev Time 0.00
Received By pvalenti Date 2021-08-03 Time 10:45 Sent To  
Notes
2021-08-03 11:27:16****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PROVIDE THE CONNECTION DETAILS INCLUDING
 ANY FRAMING AND/OR REINFORCEMENT OF WALLS AND FLOORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-07-19 Cont ID  
Sent By pvalenti Date 2021-07-19 Time 14:21 Rev Time 0.00
Received By pvalenti Date 2021-07-19 Time 14:21 Sent To  
Notes
2021-07-19 14:22:25****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561?805?6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PLEASE PROVIDE DETAILS FOR ALL WORK
 APPLIED FOR INCLUDING:
  
 1) WALL INFILL AT TENANT SEPARATION (STRUCTURAL & FIRE
 RATING) DETAILS.
 2) BATHROOM WORK DETAILS.
 3) KITCHEN WORK DETAILS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-24 Cont ID  
Sent By pvalenti Date 2021-05-24 Time 07:34 Rev Time 0.00
Received By pvalenti Date 2021-05-21 Time 06:14 Sent To  
Notes
2021-05-24 07:39:11****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PLEASE PROVIDE DETAILS FOR ALL WORK
 APPLIED FOR INCLUDING:
  
 1) WALL INFILL AT TENANT SEPARATION (STRUCTURAL & FIRE
 RATING) DETAILS.
 2) BATHROOM WORK DETAILS.
 3) KITCHEN WORK DETAILS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-07-08 Cont ID  
Sent By jleahy Date 2021-07-08 Time 13:45 Rev Time 0.00
Received By jleahy Date 2021-07-08 Time 13:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-05-25 Cont ID  
Sent By jleahy Date 2021-05-25 Time 18:09 Rev Time 0.00
Received By jleahy Date 2021-05-25 Time 18:09 Sent To  
Notes
2021-05-25 18:09:59ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO ELECTRIC WORK SHOWN PLEASE ADD ELECTRIC TO PLANS FOR
 REVIEW.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-07-29 Cont ID  
Sent By pleduc Date 2021-07-29 Time   Rev Time 0.00
Received By pleduc Date 2021-07-29 Time 10:44 Sent To  
Notes
2021-07-29 10:46:02FIRE SPRINKLER LETTER STATES A REVIEW WILL TAKE PLACE
 ON COMPLETION
 TO ENSURE NO MODIFICATION IS REQUIRED.
  
 FIRE ALARM WORK SHALL BE SUBMITTED UNDER SEPARATE
 PERMIT & SHOP DRAWINGS
  
 PLEASE ENSURE COMPLIANCE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-07-06 Cont ID  
Sent By pleduc Date 2021-07-06 Time   Rev Time 0.00
Received By pleduc Date 2021-07-06 Time 14:01 Sent To  
Notes
2021-07-06 14:02:02FIRE SPRINKLER LETTER STATES A REVIEW WILL TAKE PLACE
 ON COMPLETION
 TO ENSURE NO MODIFICATION IS REQUIRED.
  
 PLEASE ENSURE COMPLIANCE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-05-24 Cont ID  
Sent By pleduc Date 2021-05-24 Time   Rev Time 0.00
Received By pleduc Date 2021-05-24 Time 15:20 Sent To  
Notes
2021-05-24 15:20:20THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THERE ARE INDICATIONS A MULTIPLE WALLS BEING REMOVED
 WITH NEW SPACES CREATED. THE BUILDING HAS AN EXISTING
 FIRE SPRINKLER AND FIRE ALARM SYSTEM.
  
 THERE IS NO INDICATION OF FIRE SPRINKLER NOR FIRE ALARM
 WORK.
  
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD, INCLUDING DEMO.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-08-05 Cont ID  
Sent By pvalenti Date 2021-08-05 Time 07:18 Rev Time 0.00
Received By pvalenti Date 2021-07-28 Time 15:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-19 Cont ID  
Sent By pvalenti Date 2021-07-19 Time 14:22 Rev Time 0.00
Received By pvalenti Date 2021-07-01 Time 09:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-10 Cont ID  
Sent By lcrespo Date 2021-06-10 Time 12:44 Rev Time 0.00
Received By lcrespo Date 2021-05-25 Time 13:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-07-08 Cont ID  
Sent By medwards Date 2021-07-08 Time 15:00 Rev Time 0.00
Received By medwards Date 2021-07-08 Time 15:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-05-25 Cont ID  
Sent By medwards Date 2021-05-25 Time 14:00 Rev Time 0.00
Received By medwards Date 2021-05-25 Time 14:00 Sent To  
Notes
2021-05-25 14:02:48PLEASE PROVIDE BATH EXHAUST DETAILS, SUCH AS THE DUCT
 MATERIAL AND WHERE THE EXHAUST TERMINATION IS LOCATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-08-04 Cont ID  
Sent By lcrespo Date 2021-08-04 Time 16:19 Rev Time 0.00
Received By lcrespo Date 2021-08-04 Time 16:19 Sent To  
Notes
2021-08-04 16:20:2608/04/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-07-13 Cont ID  
Sent By lcrespo Date 2021-07-13 Time 14:16 Rev Time 0.00
Received By lcrespo Date 2021-07-13 Time 14:15 Sent To  
Notes
2021-07-13 14:18:2507/13/21 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 SECOND REQUEST, NON OF THE COMMENTS WHERE ADDRES!
  
 1. PLEASE PROVIDE INFORMATION AND PLANS CORRESPONDING
 TO THE TYPE OF OCCUPANCY AND ACCESSIBILITY PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 2. ON SHEET A-2;
  
 A. PLEASE PROVIDE A PLUMBING RISER DIAGRAM FOR THE
 BATHROOM AND WASHING MACHINE AND KITCHEN PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL
 PLUMBING.
  
 B. PLEASE GIVE THE NUMBER OF OCCUPANT'S NUMBER, TYPE,
 AND CALCIFICATION TO DETERMINE THE MINIMUM FIXTURES. IF
 COMMERCIAL OCCUPANCY WILL BE USED.
  
 3. THE PLANS SHOW A STACKABLE UNIT. IF THIS IS A
 COMMERCIAL UNIT, IT WILL NEED A LINT TRAP AT THE
 WASHING MACHINE; PLEASE PROVIDE THE SPECIFICATION AND
 SHOW IT ON ISOMETRIC PER THE 2020 FC SEC P 1003.6
 CLOTHES WASHER DISCHARGE INTERCEPTOR.
  
 4. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE
 ACCESSIBLE WITHOUT MOVING THE UNIT WITHIN REACH PER THE
 2020 FBC SEC. P 606.3 ACCESS TO VALVES.
  
 5. ON SHEET P-2;
 A. THIS UNIT IS CONSTRUCTED UNDER THE REQUIREMENTS OF
 THE FAIR HOUSING ACT. PLEASE INDICATE ON THE PLANS
 WHICH DESIGN SPECIFICATIONS WILL BE USED AND WAS USED
 IN THE ORIGINAL DESIGN OF UNIT IN THE FIRST FLOOR
 BATHROOM. THE LEVEL OF ACCESSIBILITY CANNOT BE
 DECREASED. THE PLANNED ALTERATIONS TO THE DOWN STAIRS
 BATH DO NOT COMPLY WITH THE REQUIREMENTS OF THE FAIR
 HOUSING ACT GUIDELINES.
  
 B. PLEASE SHOW DIMENSION BETWEEN FIXTURES INSTALLATION
 TO CONFORM TO THE 2020 FBC SEC. P 405.3.1 WATER CLOSET,
 LAV AND P 421.4. SHOWER.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-10 Cont ID  
Sent By lcrespo Date 2021-06-10 Time 12:44 Rev Time 0.00
Received By lcrespo Date 2021-06-10 Time 12:44 Sent To  
Notes
2021-06-10 15:29:4606/10/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE PROVIDE INFORMATION AND PLANS CORRESPONDING
 TO THE TYPE OF OCCUPANCY AND ACCESSIBILITY PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 2. ON SHEET A-2;
  
 A. PLEASE PROVIDE A PLUMBING RISER DIAGRAM FOR THE
 BATHROOM AND WASHING MACHINE AND KITCHEN PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL
 PLUMBING.
  
 B. PLEASE GIVE THE NUMBER OF OCCUPANT?S NUMBER, TYPE,
 AND CALCIFICATION TO DETERMINE THE MINIMUM FIXTURES. IF
 COMMERCIAL OCCUPANCY WILL BE USED.
  
 3. THE PLANS SHOW A STACKABLE UNIT. IF THIS IS A
 COMMERCIAL UNIT, IT WILL NEED A LINT TRAP AT THE
 WASHING MACHINE; PLEASE PROVIDE THE SPECIFICATION AND
 SHOW IT ON ISOMETRIC PER THE 2020 FC SEC P 1003.6
 CLOTHES WASHER DISCHARGE INTERCEPTOR.
  
 4. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE
 ACCESSIBLE WITHOUT MOVING THE UNIT WITHIN REACH PER THE
 2020 FBC SEC. P 606.3 ACCESS TO VALVES.
  
 5. ON SHEET P-2;
 A. THIS UNIT IS CONSTRUCTED UNDER THE REQUIREMENTS OF
 THE FAIR HOUSING ACT. PLEASE INDICATE ON THE PLANS
 WHICH DESIGN SPECIFICATIONS WILL BE USED AND WAS USED
 IN THE ORIGINAL DESIGN OF UNIT IN THE FIRST FLOOR
 BATHROOM. THE LEVEL OF ACCESSIBILITY CANNOT BE
 DECREASED. THE PLANNED ALTERATIONS TO THE DOWN STAIRS
 BATH DO NOT COMPLY WITH THE REQUIREMENTS OF THE FAIR
 HOUSING ACT GUIDELINES.
  
 B. PLEASE SHOW DIMENSION BETWEEN FIXTURES INSTALLATION
 TO CONFORM TO THE 2020 FBC SEC. P 405.3.1 WATER CLOSET,
 LAV AND P 421.4. SHOWER.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-30 Cont ID  
Sent By medwards Date 2021-07-30 Time 13:51 Rev Time 0.00
Received By medwards Date 2021-07-30 Time 13:41 Sent To  
Notes
2021-07-30 13:52:17ORIGINAL SIGNED AND SEALED PAPER DOCUMENTS ROUTED TO
 STORAGE.ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-05-07 Cont ID  
Sent By medwards Date 2021-05-07 Time 13:56 Rev Time 0.00
Received By medwards Date 2021-05-07 Time 13:55 Sent To  
Notes
2021-05-07 13:57:10ORIGINAL SIGNED AND SEALED PAPER DOCUMENTS ROUTED TO
 STORAGE.ME