Plan Review Details - Permit 21041630
Plan Review Stops For Permit 21041630
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2021-07-19 Cont ID  
Sent By pvalenti Date 2021-07-19 Time 14:27 Rev Time 0.00
Received By pvalenti Date 2021-07-19 Time 14:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-08-03 Cont ID  
Sent By pvalenti Date 2021-08-03 Time 10:41 Rev Time 0.00
Received By pvalenti Date 2021-08-03 Time 10:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-07-19 Cont ID  
Sent By pvalenti Date 2021-07-19 Time 14:28 Rev Time 0.00
Received By pvalenti Date 2021-07-19 Time 14:25 Sent To  
Notes
2021-07-19 14:31:16****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561?805?6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PLEASE PROVIDE THE DETAILS INCLUDING THE
 FOLLOWING:
  
 1) STRUCTURAL & FIRE RATING DETAILS FOR THE INFILL OF
 TENANT SEPARATION WALLS.
 2) STRUCTURAL & FIRE RATING (IF APPLICABLE) DETAILS OF
 BATHROOM.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-24 Cont ID  
Sent By pvalenti Date 2021-05-24 Time 07:04 Rev Time 0.00
Received By pvalenti Date 2021-05-21 Time 06:11 Sent To  
Notes
2021-05-24 07:10:20****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PLEASE PROVIDE THE DETAILS INCLUDING THE
 FOLLOWING:
  
 1) STRUCTURAL & FIRE RATING DETAILS FOR THE INFILL OF
 TENANT SEPARATION WALLS.
 2) STRUCTURAL & FIRE RATING (IF APPLICABLE) DETAILS OF
 BATHROOM.
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-08-05 Cont ID  
Sent By jleahy Date 2021-08-05 Time 12:51 Rev Time 0.00
Received By jleahy Date 2021-08-05 Time 12:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2021-07-08 Cont ID  
Sent By jleahy Date 2021-07-08 Time 12:16 Rev Time 0.00
Received By jleahy Date 2021-07-08 Time 12:13 Sent To  
Notes
2021-07-08 12:51:51SEE REVIEW COMMENTS FROM 5/25/21 JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-05-25 Cont ID  
Sent By jleahy Date 2021-05-25 Time 18:07 Rev Time 0.00
Received By jleahy Date 2021-05-25 Time 17:48 Sent To  
Notes
2021-05-25 18:08:30ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO ELECTRIC WORK SHOWN PLEASE ADD ELECTRIC TO PLANS FOR
 REVIEW.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-07-06 Cont ID  
Sent By pleduc Date 2021-07-06 Time   Rev Time 0.00
Received By pleduc Date 2021-07-06 Time 13:57 Sent To  
Notes
2021-07-06 14:04:03FIRE SPRINKLER LETTER STATES A REVIEW WILL TAKE PLACE
 ON COMPLETION
 TO ENSURE NO MODIFICATION IS REQUIRED.
  
 PLEASE ENSURE COMPLIANCE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-05-24 Cont ID  
Sent By pleduc Date 2021-05-24 Time   Rev Time 0.00
Received By pleduc Date 2021-05-24 Time 15:18 Sent To  
Notes
2021-05-24 15:19:15THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THERE ARE INDICATIONS A MULTIPLE WALLS BEING REMOVED
 WITH NEW SPACES CREATED. THE BUILDING HAS AN EXISTING
 FIRE SPRINKLER AND FIRE ALARM SYSTEM.
  
 THERE IS NO INDICATION OF FIRE SPRINKLER NOR FIRE ALARM
 WORK.
  
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD, INCLUDING DEMO.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-08-05 Cont ID  
Sent By jleahy Date 2021-08-05 Time 12:52 Rev Time 0.00
Received By jleahy Date 2021-07-29 Time 14:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-19 Cont ID  
Sent By pvalenti Date 2021-07-19 Time 14:31 Rev Time 0.00
Received By pvalenti Date 2021-07-01 Time 08:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-10 Cont ID  
Sent By lcrespo Date 2021-06-10 Time 12:43 Rev Time 0.00
Received By lcrespo Date 2021-05-25 Time 13:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-08-04 Cont ID  
Sent By lcrespo Date 2021-08-04 Time 16:32 Rev Time 0.00
Received By lcrespo Date 2021-08-04 Time 16:32 Sent To  
Notes
2021-08-04 16:33:0308/04/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-07-13 Cont ID  
Sent By lcrespo Date 2021-07-13 Time 14:13 Rev Time 0.00
Received By lcrespo Date 2021-07-13 Time 14:13 Sent To  
Notes
2021-07-13 14:14:5507/13/21 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 SECOND REQUEST, NON OF THE COMMENTS WHERE ADDRES!
  
 1. PLEASE PROVIDE INFORMATION AND PLANS CORRESPONDING
 TO THE TYPE OF OCCUPANCY THIS UNIT WILL BE. A KITCHEN
 IS NOT SHOWN ON PLAN PLEASE PROVIDE ON PLANS PER THE
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 2. ON SHEET A-2;
  
 A. PLEASE PROVIDE A PLUMBING RISER DIAGRAM FOR THE
 BATHROOM AND WASHING MACHINE PER THE WPB AMENDMENTS TO
 THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING.
  
 B. PLEASE GIVE THE NUMBER OF OCCUPANTS NUMBER, TYPE,
 AND CALCIFICATION TO DETERMINE THE MINIMUM FIXTURES IF
 APPLICABLE.
  
 3. THE PLANS SHOW A STACKABLE UNIT. IF THIS IS A
 COMMERCIAL UNIT, IT WILL NEED A LINT TRAP AT THE
 WASHING MACHINE; PLEASE PROVIDE THE SPECIFICATION AND
 SHOW IT ON ISOMETRIC PER THE 2020 FC SEC P 1003.6
 CLOTHES WASHER DISCHARGE INTERCEPTOR.
  
 4. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE
 ACCESSIBLE WITHOUT MOVING THE UNIT WITHIN REACH PER THE
 2020 FBC SEC. P 606.3 ACCESS TO VALVES.
  
 5. PLEASE SHOW DIMENSION BETWEEN FIXTURES INSTALLATION
 TO CONFORM TO THE 2020 FBC SEC. P 405.3.1 WATER CLOSET,
 LAV AND P 421.4. SHOWER.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-10 Cont ID  
Sent By lcrespo Date 2021-06-10 Time 12:42 Rev Time 0.00
Received By lcrespo Date 2021-06-10 Time 12:42 Sent To  
Notes
2021-06-10 12:42:5906/10/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE PROVIDE INFORMATION AND PLANS CORRESPONDING
 TO THE TYPE OF OCCUPANCY THIS UNIT WILL BE. A KITCHEN
 IS NOT SHOWN ON PLAN PLEASE PROVIDE ON PLANS PER THE
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 2. ON SHEET A-2;
  
 A. PLEASE PROVIDE A PLUMBING RISER DIAGRAM FOR THE
 BATHROOM AND WASHING MACHINE PER THE WPB AMENDMENTS TO
 THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING.
  
 B. PLEASE GIVE THE NUMBER OF OCCUPANTS NUMBER, TYPE,
 AND CALCIFICATION TO DETERMINE THE MINIMUM FIXTURES IF
 APPLICABLE.
  
 3. THE PLANS SHOW A STACKABLE UNIT. IF THIS IS A
 COMMERCIAL UNIT, IT WILL NEED A LINT TRAP AT THE
 WASHING MACHINE; PLEASE PROVIDE THE SPECIFICATION AND
 SHOW IT ON ISOMETRIC PER THE 2020 FC SEC P 1003.6
 CLOTHES WASHER DISCHARGE INTERCEPTOR.
  
 4. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE
 ACCESSIBLE WITHOUT MOVING THE UNIT WITHIN REACH PER THE
 2020 FBC SEC. P 606.3 ACCESS TO VALVES.
  
 5. PLEASE SHOW DIMENSION BETWEEN FIXTURES INSTALLATION
 TO CONFORM TO THE 2020 FBC SEC. P 405.3.1 WATER CLOSET,
 LAV AND P 421.4. SHOWER.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-30 Cont ID  
Sent By medwards Date 2021-07-30 Time 15:09 Rev Time 0.00
Received By medwards Date 2021-07-30 Time 15:09 Sent To  
Notes
2021-07-30 15:09:53ORIGINAL SIGNED AND SEALED PAPER DOCUMENTS ROUTED TO
 STORAGE. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-05-07 Cont ID  
Sent By medwards Date 2021-05-07 Time 13:53 Rev Time 0.00
Received By medwards Date 2021-05-07 Time 13:52 Sent To  
Notes
2021-05-07 13:53:45SIGNED AND SEALED PAPER DOCUMENTS ROUTED TO STORAGE.ME