Plan Review Details - Permit 21041507
Plan Review Stops For Permit 21041507 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-15 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-15 |
Time |
10:50 |
Sent To |
|
|
Notes |
2021-07-15 10:51:31 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE PLANS HAVE SEVERAL REFERENCES TO THE FBC SIXTH | | EDITION (2017). THE FBC SEVENTH EDITION (2020) WENT | | INTO EFFECT ON DECEMBER 31, 2020. ALL NEW PERMITS | | APPLIED FOR ON OR AFTER THAT DATE ARE REQUIRED TO | | COMPLY WITH AND REFERENCE THE 2020 FBC SEVENTH EDITION. | | FS CHAPTER 553 | | | | 2) THE ENGINEERING ON THE PLANS REFERENCE ASCE 7 - 10 | | AND THE CURRENT CODE REFERENCES ASCE 7-16. PLEASE | | CORRECT. 2020 FBC CHAPTER 35 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-15 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-06-14 |
Time |
10:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-15 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-15 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-06-29 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2021-06-29 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2021-06-29 |
Time |
|
Sent To |
|
|
Notes |
2021-06-29 14:47:53 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE EXISTING BUILDING APPEARS TO BE A MULTI-TENANT | | BUILDING. PER THE SIGN CODE OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDRS), ONLY ONE SIGN IS | | PERMITTED PER TENANT/BUSINESS. THE PLANS INDICATE THAT | | THERE MAY MULTIPLE SIGNS PROPOSED FOR THE PERMIT. [ZLDR | | S.94-408(D)] | | | | 2.) IT IS NOT CLEAR WHAT THE OVERALL SITE PLAN SHEET IS | | DEPICTING, AS THERE IS NO LEGEND IDENTIFYING THE | | REFERENCES IN THE SITE PLAN. | | | | 3.) BUILDING FACADE DIMENSIONS ARE REQUIRED FOR THE | | TENANT SPACE TO CALCULATE THE MAXIMUM ALLOWABLE SIGN | | AREA. [ZLDR S.94-409]. | | | | | | | | NOTES: | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: NORTHPOINT CPD | | |
|
|
|