Plan Review Details - Permit 21041499
Plan Review Stops For Permit 21041499 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-05-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-13 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-13 |
Time |
13:38 |
Sent To |
|
|
Notes |
2021-05-13 13:56:00 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) PROVIDE A SHOWER PAN DETAIL. FBC AMENDMENTS 107.2.1 | | | | 2) SPECIFY THE DIMENSIONS OF THE NEW SHOWER. FBC | | AMENDMENTS 107.2.1 | | | | 3) SHOW THE LOCATION OF THE SHOWER DRAIN. IS IT BEING | | MOVED FROM THE TUB DRAIN LOCATION? WILL THE FLOOR HAVE | | TO BE CUT? HOW WILL THE FIRE RATING OF THE FLOOR BE | | MAINTAINED? WHAT TYPE OF FIRESTOPPING WILL BE USED? FBC | | AMENDMENTS 107.2.1 | | | | 4) SPECIFY THE MATERIALS THAT WILL BE INSTALLED ON THE | | WALLS WHERE THE EXISTING TUB WAS. FBC AMENDMENTS | | 107.2.1 | | | | 5) IT APPEARS THAT A LICENSED BUILDING CONTRACTOR WILL | | BE REQUIRED TO PULL A SUB-PERMIT PERFORM THE WORK THAT | | IS NOT WITHIN THE SCOPE OF YOUR PLUMBING LICENSE. FBC | | AMENDMENTS 105 & FS 489 | | | | 6) THE COST FOR THIS WORK APPEARS TO UNDER VALUED. | | PROVIDE A COPY OF THE SIGNED CONTRACT. FBC AMENDMENTS | | 109.3 | | | | 7) PLEASE PROVIDE A RESPONSE LETTER THAT ADDRESSES EACH | | OF THE REVIEW COMMENTS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-05-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-13 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-04-30 |
Time |
06:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-05-03 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-05-03 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-05-03 |
Time |
10:18 |
Sent To |
|
|
Notes |
2021-05-03 10:18:41 | 05/03/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-05-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-13 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-13 |
Time |
13:38 |
Sent To |
|
|
Notes |
|
|
|