Plan Review Details - Permit 21041449
Plan Review Stops For Permit 21041449
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-07-07 Cont ID  
Sent By shill Date 2021-07-07 Time 17:27 Rev Time 0.00
Received By shill Date 2021-07-07 Time 17:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-06-29 Cont ID  
Sent By shill Date 2021-06-29 Time 07:01 Rev Time 0.00
Received By shill Date 2021-06-29 Time 07:01 Sent To  
Notes
2021-06-29 07:02:07SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC 2020 RESIDENTIAL 301:
  
 1. THE INSTALLATION SCHEDULE DOES NOT STATE WHAT THE
 SUBSTRATE IS - BLOCK, CONCRETE? IS THE SUBSTRATE THE
 SAME TOP AND BOTTOM?
  
 WITHOUT THIS INFORMATION, IT IS NOT POSSIBLE TO
 COMPLETE THE REVIEW.
  
 NEW COMMENT:
  
 2. THE "OPENING SIZE" COLUMN SHOULD BE WIDTH X HEIGHT.
 SINCE THE PROPOSED SHUTTERS ARE ACCORDION, THE SPAN
 SHOULD CORRELATE WITH THE HEIGHT, BUT THE DIMENSION IN
 THE COLUMN "SHUTTER SPAN" IS THE SAME AS THE WIDTH, NOT
 THE HEIGHT. REVISE THE INSTALLATION SCHEDULE
 ACCORDINGLY.
  
 3. THE COMMENTS FROM THE PREVIOUS TWO REVIEWS CANNOT BE
 EVALUATED UNTIL THE SPAN AND SUBSTRATE ARE KNOWN.
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-06-18 Cont ID  
Sent By shill Date 2021-06-18 Time 07:09 Rev Time 0.00
Received By shill Date 2021-06-18 Time 07:09 Sent To  
Notes
2021-06-18 07:13:46SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC 2020 RESIDENTIAL 301:
  
 1. THE INSTALLATION SCHEDULE DOES NOT STATE WHAT THE
 SUBSTRATE IS - BLOCK, CONCRETE? IS THE SUBSTRATE THE
 SAME TOP AND BOTTOM?
  
 2. ELCO TAPCONS IS NOT ONE LISTED ON PAGES 10-11 OF THE
 PRODUCT APPROVAL SUBMITTED. REVISE THE INSTALLATION
 SCHEDULE TO STATE WHICH FASTENER IS PROPOSED, USING THE
 EXACT LANGUAGE AS ON THE PRODUCT APPROVAL.
  
 3. 1 1/2" EDGE DISTANCE IS PROPOSED, NOTE THAT THIS
 DIMENSION IS NOT ON THE ANCHOR SCHEDULES PAGES 10-11.
 1.25 WILL BE USED UNLESS THE ANCHOR SCHEDULE IS
 REVISED.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-06-11 Cont ID  
Sent By shill Date 2021-06-11 Time 20:35 Rev Time 0.00
Received By shill Date 2021-06-11 Time 20:35 Sent To  
Notes
2021-06-11 20:36:02SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC R 2020 301, SUBMIT A PRODUCT APPROVAL FOR THE
 PROPOSED SHUTTERS.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-07-07 Cont ID  
Sent By shill Date 2021-07-07 Time 17:28 Rev Time 0.00
Received By shill Date 2021-06-30 Time 14:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-06-29 Cont ID  
Sent By shill Date 2021-06-29 Time 07:05 Rev Time 0.00
Received By shill Date 2021-06-22 Time 12:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-18 Cont ID  
Sent By shill Date 2021-06-18 Time 07:13 Rev Time 0.00
Received By shill Date 2021-06-16 Time 14:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-11 Cont ID  
Sent By shill Date 2021-06-11 Time 20:36 Rev Time 0.00
Received By shill Date 2021-05-24 Time 16:29 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved