2021-04-28 11:27:32 | 04/28/21 1ST GAS REVIEW**DENIED** WITH COMMENTS |
| |
| NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| |
| 1. PLEASE HAVE A SIGNATURE ON THE ISOMETRIC DRAWING OF |
| THE PERSON DESIGNING THE SYSTEM, NOT IN ACCORDANCE WITH |
| FLORIDA ADMINISTRATIVE CODE 61G15-23.001, FLORIDA |
| STATUTE 471 PER THE WPB AMENDMENTS TO THE FBC SEC. |
| 107.1 GENERAL. |
| |
| 2. SUBMIT MANUFACTURER'S SPECIFICATION |
| SHEETS/INSTALLATION MANUAL FOR THE RANGE TO VERIFY |
| COMPLIANCE WITH 2020 FBC RES. SEC. G2408.1. |
| |
| 3. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE |
| INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT |
| SHALL BE ONSITE AT THE TIME OF INSPECTION PER THE 2020 |
| FBC RES. SEC. G2413.2 AND G2404.3. |
| |
| 4. SUBMIT A SIZING TABLE USED IN THE DESIGN FOR THE GAS |
| SYSTEM OR PLACE A NOTE ON BOTH SETS OF PLANS LISTING |
| THE SIZING TABLES FROM GAS CODES OR ANOTHER STANDARD |
| USED IN THE DESIGN OF THIS SYSTEM PER THE 2020 FBC RES. |
| SEC. G2413.3. |
| |
| 5. PLEASE SUBMIT THE MANUFACTURER'S SPECIFICATIONS FOR |
| THE PRESSURE REGULATORS. REGULATORS INSTALLED ON THE |
| BUILDING'S EXTERIOR SHALL BE APPROVED FOR OUTDOOR |
| INSTALLATION PER THE 2020 FBC RES. SEC. G2421.1. |
| |
| 6. THE CLAIMED VALUE APPEARS TO BE UNDERESTIMATED ON |
| THE APPLICATION. PLEASE PROVIDE A BONA FIDE SIGNED |
| CONTRACT PER THE WPB AMENDMENTS TO THE FBC 109.3. |
| BUILDING PERMITS VALUATIONS. |
| |
| 7. PLEASE SHOW THE DISTANCE OF THE LOCATION OF THE |
| TANK-LESS WATER HEATER AND THE LOCATION AND DISTANCE OF |
| ANY OPERABLE DOORS OR WINDOWS IN RELATION TO THE WATER |
| HEATER. THE LOCATION OF THE WATER HEATER SHALL COMPLY |
| WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PER |
| THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION |
| ON CONSTRUCTION DOCUMENTS. |
| |
| 8. THIS UNIT REQUIRES CONDENSATE, AND IT NEEDS TO BE 1' |
| AWAY FROM THE STRUCTURE PER THE 2017 FBC SEC. R318.5. |
| PLEASE PUT NOT ON PLANS. |
| |
| 9. PIPES OR TANK-LEES NEED TO BE INSULATED WITH A |
| MINIMUM R-3 PER THE 2017 FBC SEC. RE 403.5.3 PLEASE PUT |
| A NOTE ON PLANS. |
| |
| WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & |
| REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |