Plan Review Details - Permit 21041277
Plan Review Stops For Permit 21041277
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-06-29 Cont ID  
Sent By jwitmer Date 2021-06-29 Time 08:36 Rev Time 0.00
Received By jwitmer Date 2021-06-29 Time 08:31 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-05-18 Cont ID  
Sent By jwitmer Date 2021-05-18 Time 11:28 Rev Time 0.00
Received By jwitmer Date 2021-05-18 Time 09:14 Sent To  
Notes
2021-05-18 11:26:24COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-06-29 Cont ID  
Sent By jwitmer Date 2021-06-29 Time 08:57 Rev Time 0.00
Received By jwitmer Date 2021-06-29 Time 08:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-18 Cont ID  
Sent By jwitmer Date 2021-05-18 Time 11:29 Rev Time 0.00
Received By jwitmer Date 2021-05-18 Time 09:14 Sent To  
Notes
2021-05-18 11:29:23WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21041277
 ADD:7402 S. DIXIE HWY.
 CONT: THE OWEN GROUP
 TEL: 954-444-3008
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. MAY 18TH/ 2021
 ACTION: DENIED
 1) SHEET A.02 DEMOLITION & FLOOR PLAN:
  
 1A) THE FLOOR PLAN SHOWS A COUNTER WITH SEATING. THERE
 SEAMS TO BE A DISCREPANCY IN THE PLANS. THE FLOOR PLAN
 STATES 34-INCH-HIGH SEATING. SHEET A.06 DETAIL # 1
 INDICATES THE TOP OF THE COUNTER IS 34 INCHES HIGH.
 DISCREPANCY IN THE PLANS. THE 2020 FBC-ACCESSIBILITY
 CODE SECTION 902.3 HEIGHT. THE TOPS OF DINING SURFACES
 AND WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34
 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 1B) AT THE FRONT OF THE BUILDING BETWEEN THE 2 ENTRY
 DOORS THE FLOOR PLAN STATES CUSTOM FURNITURE BY OTHERS.
 SHEET A.06 SHOWS THE ELEVATION VIEW IN DETAIL # 2 WHICH
 APPEARS TO BE AN AREA CONSIDERED A HIGH-TOP WHERE THE
 MEAL OR DRINK CAN BE CONSUMED. PLEASE PROVIDE WHAT THE
 INTENT IS IN THIS AREA. WITH 6 SEATS THE ONE SEAT MEETS
 THE REQUIREMENT FOR THE ACCESSIBILITY CODE @ 0.05
 PERCENT. THE COUNTER IN QUESTION IS 10 FEET LONG. IF
 THE PATRONS ARE STANDING @ EVERY 18 INCHES THAT WOULD
 MAKE AN ADDITIONAL 7 PATRONS PLUS THE SEATED 6 EQUALS
 13. 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902. 13 X 0.05= 0.65 THE
 0.05 PERCENT ARE STILL MET BUT DISPERSION IS A ISSUE.
  
 1C) 2020 ACCESS. CODE 226.2 DISPERSION. DINING SURFACES
 AND WORK SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE
 DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING
 DINING SURFACES AND WORK SURFACES.
  
 1D) THE OTHER UNKNOWN IS IF THERE WILL BE SEASONABLE
 SEATING ON THE EXTERIOR OF THE RESTAURANT. 2020
 FBC-ACCESS. CODE 206.2.5 206.2.5 RESTAURANTS AND
 CAFETERIAS. IN RESTAURANTS AND CAFETERIAS, AN
 ACCESSIBLE ROUTE SHALL BE PROVIDED TO ALL DINING AREAS,
 INCLUDING RAISED OR SUNKEN DINING AREAS, AND OUTDOOR
 DINING AREAS.
  
 1E) THE FLOOR PLAN INDICATES THE POINT OF SALE COUNTER
 TO BE 36 INCHES IN HEIGHT. CHECK WRITING SURFACES. 2017
 ACCESS. CODE 904.3.3 CHECK WRITING SURFACES. WHERE
 PROVIDED, CHECK WRITING SURFACES SHALL COMPLY WITH
 902.3HEIGHT. THE TOPS OF WORK SURFACES SHALL BE 28
 INCHES MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5 POSITION.
 UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE
 SHALL BE POSITIONED FOR EITHER A FORWARD OR PARALLEL
 APPROACH TO AN ELEMENT.
 904.4 SALES AND SERVICE COUNTERS. SALES COUNTERS AND
 SERVICE COUNTERS SHALL COMPLY WITH 904.4.1 OR 904.4.2.
 THE ACCESSIBLE PORTION OF THE COUNTERTOP SHALL EXTEND
 THE SAME DEPTH AS THE SALES OR SERVICE COUNTERTOP.
  
 1F) THE NEWLY EXPANDED UNISEX RESTROOM DOES NOT PROVIDE
 THE OVERALL WIDTH OF THE RESTROOM (BACK WALL) NOR DOES
 THE DETAIL 7/ A.07. THE 2020 FBC-B SECTION 604.3
 CLEARANCES.
 2) SHEET A.07:
 2) DETAILS 3 & 6 SHOW THE WATER CLOSET GRAB BARS BEING
 MEASURED FROM FINISH FLOOR TO THE CENTER LINE OF THE
 GRAB BAR. 2020 FBC-ACCESSIBILITY CODE SECTION 609.4
 POSITION OF GRAB BARS. GRAB BARS SHALL BE INSTALLED IN
 A HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE, NOT CENTERLINE.
  
 3A) SHEET S.02 & S.03 BOTH SHOW NEW STRUCTURAL STEEL
 ANGLE RE-ENFORCING BEING ADDED TO THE BAR JOIST AND
 ADDITIONAL STEEL REINFORCEMENT TO MAKE A STRUCTURAL
 FRAME FOR THE NEW RTU ON THE ROOF TOP. THIS BUILDING
 CONTAINS EITHER BOLTED AND OR WELDED CONNECTIONS. THE
 CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON
 THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL
 BE REQUIRED.
 THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO
 COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS
 SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING
 INSPECTION.
 2020 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR
 KEN CONRAD AT 561-805-6666.
  
 3B) ROOF TOP CURBS. NO PRODUCT APPROVAL WAS SUBMITTED
 THIS REVIEW CYCLE. COMPONENTS & CLADDING. 2020 FBC-B
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF REPORT
 NOA, CURBS, ROOF TOP VENTILATORS.
  
 3C) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL
 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 3D) SECTION 5 OF SHEET S.03 SHOWS THE ANCHORING OF THE
 CURB TO THE NEW ROOF TOP ANGLE IRON BUT THERE IS NO
 INFORMATION AS HOW THE NEW RTU IS GOING TO BE ANCHORED
 TO THE CURB. 2020 FBC-M- 301.15 WIND RESISTANCE.
 MECHANICAL EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE
 EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO
 RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH
 THE FLORIDA BUILDING CODE, BUILDING.
 FBC-B-1609.6.4.4.1 COMPONENTS AND CLADDING. WIND
 PRESSURE FOR EACH COMPONENT OR CLADDING ELEMENT IS TO
 BE DESIGNED FOR WIND PRESSURES COMPONENTS AND
 ATTACHMENTS.
  
 LATERAL FORCE-RESISTING SYSTEM. FOR ALL ROOF TOP
 EQUIPMENT, CURBS, FANS OR A/C STANDS, AND OR VENTS,
 DETAILED ATTACHMENT TO THE ROOF FRAMING & DECK AS WELL
 AS FROM THE CURB OR ROOF STAND TO THE EQUIPMENT ABOVE.
  
 2020 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL
 MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY
 METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT
 EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY
 AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES.
 EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE
 OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES
 SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND
 LOADS.
  
 4A) SHEET A.07 DETAIL 1 SHOWS TO THE BOTTOM OF THE
 STEEL ROOF DECK AN ELEVATION OF 14 FEET 4 INCHES AND
 WHAT APPEARS TO BE A PARAPET ABOVE THE ROOF. THIS
 INFORMATION IS NOT GIVEN. 2020 FBC-M 306.5 EQUIPMENT
 AND APPLIANCES ON ROOFS OR ELEVATED STRUCTURES. WHERE
 EQUIPMENT REQUIRING ACCESS OR APPLIANCES ARE LOCATED ON
 AN ELEVATED STRUCTURE OR THE ROOF OF A BUILDING SUCH
 THAT PERSONNEL WILL HAVE TO CLIMB HIGHER THAN 16 FEET
 (4877 MM) ABOVE GRADE TO ACCESS SUCH EQUIPMENT OR
 APPLIANCES, AN INTERIOR OR EXTERIOR MEANS OF ACCESS
 SHALL BE PROVIDED. SUCH ACCESS SHALL NOT REQUIRE
 CLIMBING OVER OBSTRUCTIONS GREATER THAN 30 INCHES (762
 MM) IN HEIGHT OR WALKING ON ROOFS HAVING A SLOPE
 GREATER THAN 4 UNITS VERTICAL IN 12 UNITS HORIZONTAL
 (33-PERCENT SLOPE). SUCH ACCESS SHALL NOT REQUIRE THE
 USE OF PORTABLE LADDERS. WHERE ACCESS INVOLVES CLIMBING
 OVER PARAPET WALLS, THE HEIGHT SHALL BE MEASURED TO THE
 TOP OF THE PARAPET WALL.
  
 4B) SHEET S.02 THE OTHER ISSUE WITH NOT KNOWING THE
 PARAPET HEIGHT IS COMPLIANCE WITH SECTION 2020 FBC-B
 1015.7 ROOF ACCESS GUARDS. GUARDS SHALL BE PROVIDED
 WHERE THE ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET
 OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND
 SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES
 ABOVE THE FLOOR, ROOF OR GRADE BELOW. THE GUARD SHALL
 BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A SPHERE
 21 INCHES (533 MM) IN DIAMETER.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-07-06 Cont ID  
Sent By jleahy Date 2021-07-06 Time 14:30 Rev Time 0.00
Received By jleahy Date 2021-07-06 Time 14:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-05-27 Cont ID  
Sent By equinone Date 2021-05-27 Time 10:30 Rev Time 0.00
Received By equinone Date 2021-05-27 Time 10:30 Sent To  
Notes
2021-05-27 10:52:50CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW:
  
 1) SHEET E2.0 PANEL B SCHEDULE: CIRCUIT FOR DOAS-1 IS
 LISTED HAS HAVING A 200 AMPS BREAKER BUT CONDUCTOR SIZE
 IS ONLY #2 CU (AMPACITY = 115 AMPS). SHEET M4.0 (HVAC
 SCHEDULES) SPECS SHOWS MCA = 137.5 AMPS AND MOCP = 150
 AMPS FOR THE UNIT
 FAN SCHEDULE. ALSO SPECS DO NOT PROVIDE WHAT ARE TOTAL
 KVA LOADS FOR THIS UNIT (FANS, COMPRESORS, ETC.).
 PLEASE CLARIFY OR PROVIDE CORRECTIONS AS NEEDED. NEC
 2017
  
 2) IF TOTAL LOADS FOR DOAS-1 ARE DIFFERENT THAN 30 KVA
 PLEASE RECALCULATE LOADS FOR PANEL B
  
  
  
 ENRIQUE QUINONEZ PE
 ELECTRICAL PLANS EXAMINER
 DEVELOPMENT SERVICES
 CITY OF WEST PAM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 [email protected]
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6746.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-05-18 Cont ID  
Sent By cwalker Date 2021-05-18 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2021-08-17 Cont ID  
Sent By pvalenti Date 2021-08-17 Time 16:17 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 15:13 Sent To  
Notes
2021-08-17 16:18:32GAS COMMENTS: APPROVED
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 CITY OF WEST PALM BEACH GAS PIPING AFFIDAVIT OR
 MANOMETER TEST DOCUMENT REQUIRED AT JOBSITE FOR FINAL
 GAS INSPECTION. CALL 561-805-6692 FOR FURTHER
 INFORMATION.
  
 PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE AS A
 DEFERRED SUBMITTAL, THE INSTALLATION MANUALS FOR ALL
 GAS APPLIANCES/EQUIPMENT/APPURTENANCES. SUBMITTALS
 SHALL BE SUBMITTED, APPROVED AND ON SITE PRIOR TO
 INSPECTION. PROCEED AT YOUR OWN RISK.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21041277 7402 S DIXIE HWY

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2021-07-13 Cont ID  
Sent By jesmith Date 2021-07-13 Time 15:17 Rev Time 0.00
Received By jesmith Date 2021-07-13 Time 14:54 Sent To  
Notes
2021-07-13 15:02:40CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017FAC=
 FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 2ND REVIEW
  
 GAS COMMENTS: DENIED
  
 1.WATER HEATER DETAIL; PER WPB FBC 107.2.1, CLARIFY THE
 FOLLOWING.
 SECOND REQUEST: SHOWS GAS- REGULATOR TO REDUCE PRESSURE
 TO 2 PSI. NOTE SHOULD STATE "REDUCE PRESSURE FROM 2 PSI
 TO .5 IN. WC" TO MATCH DESCRIPTION OF GAS REGULATOR ON
 P0.0
  
 2.SUBMIT CALCULATIONS FOR COMBUSTION AIR (NOT TO BE
 CONFUSED WITH MAKE-UP AIR.) PER THE FBC FG 304.1 CALCS
 ON P1.0;
 NEW COMMENT: AVAILABLE COMBUSTION AIR NOT NOTED. PER
 WPB FBC 107.2.1, INDICATE ON THE PLANS THE AVAILABLE
 COMBUSTION AIR (EXCESS OUTSIDE AIR MAY PROVIDE,PLEASE
 CLARIFY)
  
 3.GAS RISER: CLEARLY SHOW THE LOCATION OF ALL MP
 (STEP-DOWN) REGULATORS, VALVES AND UNIONS . A LISTED
 SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY AHEAD OF
 EACH MP REGULATOR. FBC FG 409.4
 NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE NOTE AT
 PRESSURE REGULATOR DESCRIPTION ON P0.0; ?INSTALLATION
 OF GAS REGULATOR SHALL COMPLY WITH FBC FG 410.2?
  
 4.SECOND REQUEST: NOTES ON P0.0 ARE UNCLEAR AS TO
 INTENT. WHERE DOES THE 2PSI SYSTEM END AND THE LESS
 THAN 2PSI BEGIN. PER WPB FBC 107.2.1, CLARIFY. IS A
 REGULATOR TO BE PROVIDED IMMEDIATELY DOWNSTREAM OF THE
 FPU METER/ REGULATOR TO REDUCE PRESSURE AND THEN AN
 APPLIANCE REGULATOR TO BE SUPPLIED AT THE APPLIANCE;
 PER WPB FBC 107.2.1, CLARIFY. PROVIDE TABLES FOR SIZING
 FOR (2 PSI 1LB.PRESSURE DROP 402.4(5) #40 METALLIC) AS
 WELL AS (LESS THAN 2 PSI 402.4(3) 3? WC) NOTED ..
 CLEARLY INDICATE ON THE PIPING PLAN, THE 2 PSI PIPING
 AND WHICH GAS NOTE (2 OR 7) APPLIES TO WHICH SECTIONS
 OF PIPE.
 RESPONSE IS UNCLEAR
 ALSO UG IS NOT SPECIFIED-IF PE (PLASTIC PIPING) THEN
 PROVIDE TABLE AND TRACER WIRE W/DETAIL FOR TRANSITION
 TO AG.
  
 REVISED COMMENT
 P0.0 NOTES
 A.NOTED TABLE 402.4(3) ADDRESSES SCHEDULE 40 METALLIC
 PIPING LESS THAN 2PSI/.3 IN. WC/0.60 SG
 B.TABLE 402.4(2) NOT NOTED ADDRESSES SCHEDULE 40
 METALLIC PIPING LESS THAN 2PSI/.5 IN. WC/0.60 SG WHICH
 WOULD SEEM TO MATCH YOUR NOTE FOR THE GAS REGULATOR
 DESCRIPTION.
 C.NOTED PRESSURE 2PSI/1LB. PRESSURE DROP/0.60 SG FOR
 SCHEDULE 40 METALLIC PIPING IS COVERED BY TABLE
 402.4(5)
 E.REGARDING UG PIPE FROM METER TO BUILDING AND TO WATER
 HEATER,
 1) PLEASE REFER TO FBC FG 411.1, 411.1.1, 411.1.2(1),
 (2), (3) FOR PROTECTION OF STEEL PIPING FROM CORROSION
 (TABLE 402.4(5) WOULD APPLY). THIS OPTION REQUIRES
 STRINGENT AND POSSIBLY VERY EXPENSIVE REQUIREMENTS,
 2) OR REFER TO FBC FG 407.17, 407.17.1, 407.17.2,
 407.17.3 FOR PLASTIC PIPING. FBC FG TABLE 402.4(22)
 WOULD APPLY.
  
 5. SECOND REQUEST: SUBMIT MANUFACTURER'S SPECIFICATION
 SHEETS / INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO
 VERIFY COMPLIANCE FBC FG 402.2, AND 301.3. GAS
 APPLIANCES SHALL BE LISTED AND LABELED. THE
 INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT
 SHALL BE ONSITE AT THE TIME OF INSPECTION. FBC FG 305.1
 NEW COMMENT: YOU MAY PER WPB FBC 107.2.1 AND WPB FBC
 107.3.4.1, PROVIDE AS A DEFERRED SUBMITTAL
 MANUFACTURER'S SPECIFICATION SHEETS / INSTALLATION
 MANUAL FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE FBC
 FG 402.2, AND 301.3. GAS APPLIANCES SHALL BE LISTED AND
 LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FBC FG 305.1. DOCUMENT SHALL BE SUBMITTED,
 APPROVED AND ON SITE PRIOR TO FINAL INSPECTION. PROCEED
 AT YOUR OWN RISK. PROVIDE NOTE ON THE PLANS.
  
 6.SECOND REQUEST: PER WPB FBC 107.2.1, SPECIFY THE
 UNDERGROUND PIPING MATERIAL AND PROVIDE SIZING TABLE.
 SEE REVISED COMMENT IN NOTE 4 ABOVE.
  
 7.PER WPB FBC 107.2.1, EXPLAIN THE DESIGNATION LNG ON
 THE RISER DIAGRAM. IS THIS LIQUIFIED NATURAL GAS?
 CLARIFY.
 NEW COMMENT: LIQUIFIED NATURAL GAS IS A STATE THAT IS
 USED FOR TRANSPORT (COMPRESSED BY REDUCING TEMPERATURE
 TO -250 DEGREES F AND MAINTAINED AT 4PSI) AND IS NOT
 DISTRIBUTED TO THE END USER IN THIS STATE. PER WPB FBC
 107.2.1, REVISE ALL DESIGNATION OF LNG TO NG FOR
 NATURAL GAS.
  
 8.PER WPB FBC 107.2.1, SHOW LOCATION OF THE FPU
 METER/REGULATOR ON THE PLAN VIEW.
 NEW COMMENT: PROVIDE GAS SHUT OFF VALVE AT CONSUMER
 SIDE OF METER REGULATOR PER FBC FG 409.2
 NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE SPEC FOR GAS
 SHUT-OFF VALVES TO COMPLY WITH FBC FG SECTION 409.
  
 9.NEW COMMENT: KITCHEN EQUIPMENT SCHEDULE ON P2.0 MBTUS
 DOES NOT MATCH THE KITCHEN EQUIPMENT NOTED ON P0.0 GAS
 FIXTURE LOAD SUMMARY. PER WPB FBC 107.2.1, CLARIFY AND
 RECONCILE.
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21041277 7402 S DIXIE HWY
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-06-03 Cont ID  
Sent By jesmith Date 2021-06-03 Time 16:40 Rev Time 0.00
Received By jesmith Date 2021-06-01 Time 16:17 Sent To  
Notes
2021-06-03 16:40:39FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017FAC=
 FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
  
 GAS COMMENTS: DENIED
  
 PROVISO: WATER HEATER SCHEDULE INDICATES THAT AN
 ALTERNATE MANUFACTURER MAY BE SUBMITTED TO A/E FOR
 APPROVAL AND USE. PLEASE NOTE THAT A MANUFACTURER?S
 SPECIFICATION INSTALLATION MANUAL SHALL BE SUBMITTED TO
 THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL AND IF
 DIFFERENT FROM THE CURRENT SCHEDULE A PLAN REVISION
 SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR
 REVIEW AND APPROVAL. BOTH SHALL BE ON SITE FOR FINAL
 INSPECTION.
  
 PROVISO: REGULATOR SCHEDULE INDICATES THAT AN ALTERNATE
 MANUFACTURER MAY BE SUBMITTED TO A/E FOR APPROVAL AND
 USE. PLEASE NOTE THAT A MANUFACTURER?S SPECIFICATION
 INSTALLATION MANUAL SHALL BE SUBMITTED TO THE BUILDING
 DEPARTMENT FOR REVIEW AND APPROVAL AND IF DIFFERENT
 FROM THE CURRENT SCHEDULE A PLAN REVISION SHALL BE
 SUBMITTED TO THE BUILDING DEPARTMENT FOR REVIEW AND
 APPROVAL. BOTH SHALL BE ON SITE FOR FINAL INSPECTION.
  
  
 1.WATER HEATER DETAIL; PER WPB FBC 107.2.1, CLARIFY THE
 FOLLOWING.
 A.SHOWS GAS SUPPLIED FROM FPU TANKS
 B.SHOWS GAS- REGULATOR TO REDUCE PRESSURE TO 2 PSI.
  
 2.SUBMIT CALCULATIONS FOR COMBUSTION AIR (NOT TO BE
 CONFUSED WITH MAKE-UP AIR.) PER FBC FG 304.1
  
 3.GAS RISER: CLEARLY SHOW THE LOCATION OF ALL MP
 (STEP-DOWN) REGULATORS, VALVES AND UNIONS . A LISTED
 SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY AHEAD OF
 EACH MP REGULATOR. FBC FG 409.4
  
 4.NOTES ON P0.0 ARE UNCLEAR AS TO INTENT. WHERE DOES
 THE 2PSI SYSTEM END AND THE LESS THAN 2PSI BEGIN. PER
 WPB FBC 107.2.1, CLARIFY. IS A REGULATOR TO BE PROVIDED
 IMMEDIATELY DOWNSTREAM OF THE FPU METER/ REGULATOR TO
 REDUCE PRESSURE AND THEN AN APPLIANCE REGULATOR TO BE
 SUPPLIED AT THE APPLIANCE; PER WPB FBC 107.2.1,
 CLARIFY. PROVIDE TABLES FOR SIZING FOR 2 PSI AS WELL AS
 LESS THAN 2 PSI. CLEARLY INDICATE ON THE PIPING PLAN,
 THE 2 PSI PIPING AND WHICH GAS NOTE (2 OR 7) APPLIES TO
 WHICH SECTIONS OF PIPE.
  
 5.SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE FBC FG 402.2, AND 301.3. GAS APPLIANCES
 SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS
 FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT
 THE TIME OF INSPECTION. FBC FG 305.1
  
 6.GAS RISER: CLEARLY SHOW THE LOCATION OF THE EMERGENCY
 HOOD SHUT DOWN SHUT OFF VALVE SHALL BE BELOW THE
 CEILING. THE MANUAL SHUTOFF VALVE SHALL BE UPSTREAM.
 UNION TO BE DOWN STREAM OF MANUAL VALVE. SECS. 10.4,
 10.5 OF NFPA 96-08. PROVIDE DETAIL.
  
 7.PER WPB FBC 107.2.1, SPECIFY THE UNDERGROUND PIPING
 MATERIAL AND PROVIDE SIZING TABLE.
  
 8.PER WPB FBC 107.2.1, EXPLAIN THE DESIGNATION LNG ON
 THE RISER DIAGRAM. IS THIS LIQUIFIED NATURAL GAS?
 CLARIFY.
  
 9.WHEN ADDING UP THE MBTU IN THE GAS FIXTURE LOAD
 SUMMARY, I COME UP WITH 967 MBH. THE SUMMARY INDICATES
 588 MBH. PER WPB FBC 107.2.1, CLARIFY.
  
 10.PER WPB FBC 107.2.1, SHOW LOCATION OF THE FPU
 METER/REGULATOR ON THE PLAN VIEW.
  
 11.EQUIPMENT SCHEDULE ON P2.0 IS PARTIALLY OBSCURED BY
 A STAMP. PER WPB FBC 107.2.1, REMOVE OR RELOCATE THE
 STAMP SO THAT THE ENTIRE SCHEDULE IS LEGIBLE.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21041277 7402 S DIXIE HWY

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-09-21 Cont ID  
Sent By medwards Date 2021-09-21 Time 11:56 Rev Time 0.00
Received By medwards Date 2021-09-15 Time 11:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-09-07 Cont ID  
Sent By medwards Date 2021-09-07 Time 08:40 Rev Time 0.00
Received By medwards Date 2021-09-03 Time 09:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-08-17 Cont ID  
Sent By pvalenti Date 2021-08-17 Time 16:25 Rev Time 0.00
Received By pvalenti Date 2021-08-04 Time 06:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-14 Cont ID  
Sent By medwards Date 2021-07-14 Time 07:38 Rev Time 0.00
Received By medwards Date 2021-06-28 Time 08:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-03 Cont ID  
Sent By jesmith Date 2021-06-03 Time 17:05 Rev Time 0.00
Received By jesmith Date 2021-06-03 Time 17:05 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2021-05-18 Cont ID  
Sent By jwitmer Date 2021-05-18 Time 11:29 Rev Time 0.00
Received By jwitmer Date 2021-05-18 Time 09:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2021-09-21 Cont ID  
Sent By medwards Date 2021-09-21 Time 11:56 Rev Time 0.00
Received By medwards Date 2021-09-21 Time 11:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2021-09-07 Cont ID  
Sent By medwards Date 2021-09-07 Time 08:37 Rev Time 0.00
Received By medwards Date 2021-09-07 Time 08:37 Sent To  
Notes
2021-09-07 08:39:08RESPONSE LETTER INDICATES THE OUTDOOR AIR CALCULATIONS
 WERE ON SHEET M4.0. I DO NOT SEE THE OUTDOOR AIR
 CALCULATIONS. PLEASE SUBMIT THE OUTDOOR AIR
 CALCULATIONS AS REQUESTED IN THE PREVIOUS CYCLE
 REVIEWS. FBC 107.2.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2021-08-17 Cont ID  
Sent By medwards Date 2021-08-17 Time 14:31 Rev Time 0.00
Received By medwards Date 2021-08-17 Time 14:31 Sent To  
Notes
2021-08-17 14:32:193RD REVIEW FBC-2020 MECHANICAL
 PERMIT-21041277
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M4.0: PER FBC M 403.3.1.1 AND TABLE 403.3.1.1
 AND THE SQUARE FOOTAGE GIVEN FROM THE DESIGNER FOR THE
 OUTDOOR AIR CALCULATIONS THE FOLLOWING ARE THE REQUIRED
 OUTDOOR AIR CALCULATIONS REQUIRED FOR THE USE OF SPACE.
  
 KITCHEN: 490/1000 = .49 X 20 = 9.8 PEOPLE X 7.5 = 73.5
 + 490 X .12 = 132.3 REQUIRED FOR OUTDOOR AIR. KITCHEN
 EXHAUST: 490 X .7 = 343 CFM OF EXHAUST.
  
 WORKROOM WHICH IS LOCATED IN THE KITCHEN WITH NO
 SEPARATION MUST BE COUNTED AS KITCHEN: 229/1000 = .229
 X 20 = 4.58 PEOPLE X 7.5 = 34.35 + 229 X .12 = 61.83
 CFM OF REQUIRED OUTDOOR AIR. KITCHEN EXHAUST: 229 X .7
 = 160 CFM OF EXHAUST.
  
 SEATING AREA: 195/1000 = .195 X 70 = 13.65 PEOPLE X 7.5
 = 102.38 + 195 X .18 = 138.02 OF REQUIRED OUTDOOR AIR.
  
 KITCHEN PREP: 123/1000 = .123 X 20 = 2.46 PEOPLE X 7.5
 = 18.45 + 123 X .12 = 33.21 CFM OF REQUIRED OUTDOOR
 AIR. KITCHEN EXHAUST: 123 X .7 = 86 CFM OF EXHAUST.
  
 IF SQUARE FOOTAGE IS NOT NET PLEASE SEE FOOTNOTE (A )
 FBC M TABLE 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2021-07-06 Cont ID  
Sent By medwards Date 2021-07-06 Time 13:31 Rev Time 0.00
Received By medwards Date 2021-07-06 Time 13:31 Sent To  
Notes
2021-07-06 13:32:022ND REVIEW FBC-2020 MECHANICAL
 PERMIT-21041277
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE AN OUTDOOR CALCULATION FOR EACH USE
 OF SPACE INDICATED ON SHEET A.01: ASSEMBLY-135 SQ. FT.,
 KITCHEN-776 SQ. FT., STORAGE-235 SQ. FT. DO NOT SHOW
 THE HOOD EXHAUST OR MAKE UP AIR IN THIS OUTDOOR AIR
 CALCULATIONS AS THEY SHOULD BE SUBMITTED WITH CORRECTED
 RATES WHEN THE KITCHEN HOOD AND GREASE DUCT PERMIT IS
 SUBMITTED. FBC M 403.3.1.1 AND TABLE 403.3.1.1
  
 2) PLEASE ADD A NOTE ON THE MECHANICAL SCHEDULES SHEET
 THAT THE DESIGN AIR BALANCE REPORT WILL BE SUBMITTED
 WHEN COMPLETED. FBC M 508.1.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-06-01 Cont ID  
Sent By medwards Date 2021-06-01 Time 13:34 Rev Time 0.00
Received By medwards Date 2021-06-01 Time 13:34 Sent To  
Notes
2021-06-01 13:34:151ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21041277
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PLACE NOTE ON THE DRAWINGS INDICATING THAT
 ALL HOODS AND DUCTWORK WILL BE SUBMITTED AS A SEPARATE
 PERMIT AND REVIEW AS THEY WILL NOT BE REVIEWED WITH THE
 MECHANICAL SYSTEMS.
  
 2) PLEASE PLACE A NOTE ON THE DRAWINGS INDICATING THAT
 THE REFRIGERATION EQUIPMENT WILL BE SUBMITTED AS A
 SEPARATE PERMIT AND REVIEW AS THEY WILL NOT BE REVIEWED
 WITH THE MECHANICAL SYSTEMS.
  
 3) PLEASE SHOW THAT ALL ROOFTOP EQUIPMENT WILL MEET FBC
 M 304.11 FOR GUARDS ON THE ROOF.
  
 4) PLEASE SHOW THAT THE RETURN IN THE KITCHEN MEETS THE
 10 FT CLEARANCE FROM COOKING APPLIANCES. FBC M 601.5
 EXCEPTION 1.
  
 5) PLEASE PROVIDE AN OUTDOOR AIR CALCULATION FOR EACH
 USE OF SPACE BASED ON FBC M 403.3.1.1 AND TABLE
 403.3.1.1
  
 6) PLEASE PROVIDE THE DESIGN AIR BALANCE REPORT. FBC M
 508.1.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-08-17 Cont ID  
Sent By pvalenti Date 2021-08-17 Time 16:19 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 15:14 Sent To  
Notes
2021-08-17 16:21:11PLUMBING COMMENTS: APPROVED
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 A BACKFLOW PREVENTER IS REQUIRED ON THE HOT WATER
 CONNECTION TO THE WATER METER
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21041277 7402 S DIXIE HWY

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-07-13 Cont ID  
Sent By jesmith Date 2021-07-13 Time 16:15 Rev Time 0.00
Received By jesmith Date 2021-07-13 Time 15:27 Sent To  
Notes
2021-07-13 16:10:44CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017FAC=
 FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 2ND REVIEW
 PLUMBING COMMENTS: DENIED
  
 PROVISO: WATER HEATER SCHEDULE INDICATES THAT AN
 ALTERNATE MANUFACTURER MAY BE SUBMITTED TO A/E FOR
 APPROVAL AND USE. PLEASE NOTE THAT A MANUFACTURER'S
 SPECIFICATION/INSTALLATION MANUAL SHALL BE SUBMITTED TO
 THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL AND IF
 DIFFERENT FROM THE CURRENT SCHEDULE A PLAN REVISION
 SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR
 REVIEW AND APPROVAL. BOTH SHALL BE ON SITE FOR FINAL
 INSPECTION. SEE WPB FBC 107.2.1 AND WPB FBC 107.3.4.1,
 DEFERRED SUBMITTALS. PROCEED AT YOUR OWN RISK.
  
 1. SECOND REQUEST: PER FBC 606.5 EXPOSED PIPES AND
 SURFACES. WATER SUPPLY & DRAINPIPES UNDER LAVATORIES
 AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO
 PROTECT AGAINST CONTACT. PLANS SHOW INSULATED P-TRAP
 BUT DO NOT INDICATE WATER SUPPLY PIPES.
  
 2.SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE
 STRUCTURAL DETAIL FOR MOUNTING OF THE TANKLESS WATER
 HEATER.
  
 3. SECOND REQUEST: PER FBC PL 419.5, COLD OR TEMPERED
 WATER SHALL BE DELIVERED FROM LAVATORIES AND GROUP WASH
 FIXTURES LOCATED IN PUBLIC TOILET FACILITIES PROVIDED
 FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED WATER
 SHALL BE DELIVERED THROUGH AN APPROVED
 WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE
 1070 OR CSA B125.3.
 BMC RESPONSE: PLUMBING FIXTURE SCHEDULE HAS BEEN
 PROVIDED, WHICH DOES INDICATE THE TEMPERATURE LIMITING
 DEVICE FOR LAVATORIES AND HAND SINKS.
 NEW COMMENT: CANNOT FIND THE NOTED PLUMBING FIXTURE
 SCHEDULE ON THE PLANS.
  
 4.NEW COMMENT REGARDING THE WATER METER: PER WPB FBC
 107.2.1, PROVIDE MANUFACTURER?S
 SPECIFICATION/INSTALLATION MANUAL; ESPECIALLY SHOW
 INTEGRAL BACKFLOW PROTECTION, OR SPECIFY AND PROVIDE
 LEAD FREE BACKFLOW PREVENTER
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21041277 7402 S DIXIE HWY
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-03 Cont ID  
Sent By jesmith Date 2021-06-03 Time 15:30 Rev Time 0.00
Received By jesmith Date 2021-06-01 Time 16:11 Sent To  
Notes
2021-06-03 15:30:15CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 PROVISO: WATER HEATER SCHEDULE INDICATES THAT AN
 ALTERNATE MANUFACTURER MAY BE SUBMITTED TO A/E FOR
 APPROVAL AND USE. PLEASE NOTE THAT A MANUFACTURER?S
 SPECIFICATION INSTALLATION MANUAL SHALL BE SUBMITTED TO
 THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL AND IF
 DIFFERENT FROM THE CURRENT SCHEDULE A PLAN REVISION
 SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR
 REVIEW AND APPROVAL. BOTH SHALL BE ON SITE FOR FINAL
 INSPECTION.
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC
 CHAPTERS 2, 3 AND 6 PROVIDE PLAN AND ELEVATION DETAILS
 FOR NEW TOILET ROOM INDICATING THE FOLLOWING:
 A.THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM TO 18
 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION PER FBC
 ACC 604.2
 B.TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15
 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS PER FBC
 ACC 604.8.
 C.THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH
 FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES
 (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS
 SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION PER
 FBC ACC 604.4.
 D.PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED IN A
 HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP (NOT
 THE CENTER) OF THE GRIPPING SURFACE,
 E.LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE
 FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34
 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 606.3, ADDITIONALLY SHOW TOE AND KNEE CLEARANCE AS
 REQUIRED BY FBC ACC 306.2 AND 306.3
 F.PER FBC 606.5 EXPOSED PIPES AND SURFACES. WATER
 SUPPLY & DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE
 INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST
 CONTACT.
 G.MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND. PLUMBING
  
 2.P1.0 SANITARY RISER; PER WPB FBC 107.2.1, SIZE NEW
 COMBINATION WASTE AND VENT BRANCH AND FIXTURE DRAINS.
  
 3.P1.0 DEMO KEYED NOTE 8: REMOVE EXISTING FLOOR SINK
 AND CONVERT TO HUB DRAIN.
 PER FBC PL 802.4, A HUB DRAIN RECEIVES ONLY CLEAR WATER
 WASTE. ALL OTHER WASTE RECEPTORS SHALL BE PROVIDED WITH
 A REMOVABLE STRAINER OR BASKET; PER FBC PL 1003.2,
 CLEAR WATER WASTE SHALL NOT DISCHARGE TO A GREASE
 INTERCEPTOR. THE HUB DRAIN SHALL CONNECT TO THE
 SANITARY, TRAPPED AND VENTED IN ACCORDANCE WITH FBC PL
 909.1 AND 1002.1. WASTE RECEPTOR SHALL BE PROVIDED WITH
 READY ACCESS PER FBC PL 802.4. (SEE FBC PL 202
 DEFINITIONS: READY ACCESS. THAT WHICH ENABLES A
 FIXTURE, APPLIANCE OR EQUIPMENT TO BE DIRECTLY REACHED
 WITHOUT REQUIRING THE REMOVAL OR MOVEMENT OF ANY PANEL,
 DOOR OR SIMILAR OBSTRUCTION AND WITHOUT THE USE OF A
 PORTABLE LADDER, STEP STOOL OR SIMILAR DEVICE.)
  
 4.HUB DRAIN AT PASTA COOKER
 PER FBC PL 802.4, A HUB DRAIN RECEIVES ONLY CLEAR WATER
 WASTE. ALL OTHER WASTE RECEPTORS SHALL BE PROVIDED WITH
 A REMOVABLE STRAINER OR BASKET; PER FBC PL 1003.2,
 CLEAR WATER WASTE SHALL NOT DISCHARGE TO A GREASE
 INTERCEPTOR. THE HUB DRAIN SHALL CONNECT TO THE
 SANITARY, TRAPPED AND VENTED IN ACCORDANCE WITH FBC PL
 909.1 AND 1002.1. WASTE RECEPTOR SHALL BE PROVIDED WITH
 READY ACCESS PER FBC PL 802.4. (SEE FBC PL 202
 DEFINITIONS: READY ACCESS. THAT WHICH ENABLES A
 FIXTURE, APPLIANCE OR EQUIPMENT TO BE DIRECTLY REACHED
 WITHOUT REQUIRING THE REMOVAL OR MOVEMENT OF ANY PANEL,
 DOOR OR SIMILAR OBSTRUCTION AND WITHOUT THE USE OF A
 PORTABLE LADDER, STEP STOOL OR SIMILAR DEVICE.)
  
 5.THE LATEST RECORD DRAWING OF THE EXISTING FACILITY
 THAT I HAVE LOCATED (SEE PERMIT 00021049, CONTACT MR.
 CRAIG MCPHERSON PHONE 561-805-6684 EMAIL
 [email protected] FOR A RECORDS REQUEST IF YOU WISH TO
 REVIEW THE PLANS YOURSELF ) INDICATES A NEW 750 GALLON
 GREASE INTERCEPTOR, NOT A 1250 GALLON AS NOTED ON P1.0.
 ADDITIONALLY, THERE ARE OTHER INCONSISTENCIES BETWEEN
 THAT RECORD DRAWING AND THE EXISTING SYSTEM AS SHOWN ON
 P1.0.
  
 6.PER WPB FBC 107.2.1, INDICATE THE CORRECT SIZE OF THE
 EXISTING GREASE INTERCEPTOR ON THE PLANS AND PROVIDE
 NEW CALCULATIONS FOR SIZING OF THE GREASE INTERCEPTOR.
  
 7.TO INSURE THAT COMBINATION WASTE AND VENT SYSTEM
 DISCHARGING TO THE GREASE INTERCEPTOR IS COMPLIANT WITH
 FBC PL 915, PROVIDE A VENT CONNECTED VERTICALLY TO THE
 NEW GREASY WASTE BRANCH (ANYWHERE ON THE BRANCH).
 PLEASE NOTE THAT ONLY IF THE EXISTING WASTE PIPING
 CONNECTING THE NEW HAND SINKS TO THE BRANCH IS SIZED 4
 INCH, (THE SAME AS THE EXISTING COMBINATION WASTE AND
 VENT SYSTEM) MAY THE EXISTING VENT ALSO SERVE AS THE
 VENT FOR THE NEW BRANCH.
  
 8.PER WPB FBC 107.2.1, PROVIDE DRAINAGE FIXTURE UNIT
 COUNT FOR FIXTURES, DRAINS AND KITCHEN EQUIPMENT.
  
 9.PER WPB FBC 107.2.1, PROVIDE AT PIPE HANGER DETAIL
 NOTE STATING, "HORIZONTAL PIPE SHALL BE SUPPORTED IN
 ACCORDANCE WITH FBC PL TABLE 308.5."
  
 10.WATER HEATER DETAIL: PER WPB FBC 107.2.1, CLARIFY
 THE FOLLOWING ITEMS.
 A.HOW MANY TANKLESS WATER HEATERS ARE ACTUALLY TO BE
 INSTALLED. WATER RISER, PLAN VIEW, KEY NOTES AND GAS
 FIXTURE LOAD SUMMARY INDICATE ONE (1). THE DETAIL
 INDICATES TWO (2).
 B.WHAT IS THE PURPOSE OF THE EXPANSION TANK ON THE HOT
 WATER?
 C.IS/ARE THE T&P RELIEF DISCHARGE()S DISCHARGING TO THE
 EXTERIOR GRADE? WHAT IS THE PURPOSE OF THE
 NEUTRALIZERS?
 E.THERE IS NO RECIRCULATING SYSTEM SHOWN ON THE WATER
 RISER OR PLAN VIEW BUT IS NOTED ON THE DETAIL.
  
 11.PER WPB FBC 107.2.1, PROVIDE STRUCTURAL DETAIL FOR
 MOUNTING OF THE TANKLESS WATER HEATER.
  
 12.PER FBC PL 419.5, COLD OR TEMPERED WATER SHALL BE
 DELIVERED FROM LAVATORIES AND GROUP WASH FIXTURES
 LOCATED IN PUBLIC TOILET FACILITIES PROVIDED FOR
 CUSTOMERS, PATRONS AND VISITORS. TEMPERED WATER SHALL
 BE DELIVERED THROUGH AN APPROVED WATER-TEMPERATURE
 LIMITING DEVICE THAT CONFORMS TO ASSE 1070 OR CSA
 B125.3.
  
 13.PER FBC PL 606.1.5, PROVIDE FULL OPEN VALVE ON THE
 TOP OF EVERY WATER DOWN-FEED PIPE IN OCCUPANCIES OTHER
 THAN ONE- AND TWO-FAMILY RESIDENTIAL OCCUPANCIES.
 YES/NO? EXISTING
  
 14.PER WPB FBC 107.2.1, PROVIDE HOT WATER INSULATION
 SPECIFICATION; INSULATE HOT WATER IN ACCORDANCE WITH
 FBC PL E607.5 AND FBC EC C404.4.
  
 15.DETAIL FOR INDIRECT WASTE PIPING FROM COMMERCIAL
 SINK TO FLOOR SINK SHOWS A TRAP PRIMER CONNECTION. PER
 WPB 107.2.1, CLARIFY AS THE INDIRECT WASTE ITSELF IS
 WHAT REPLENISHES THE TRAP SEAL.
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21041277 7402 S DIXIE HWY
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2021-09-21 Cont ID  
Sent By medwards Date 2021-09-21 Time 11:56 Rev Time 0.00
Received By medwards Date 2021-09-21 Time 11:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2021-09-07 Cont ID  
Sent By medwards Date 2021-09-07 Time 08:39 Rev Time 0.00
Received By medwards Date 2021-09-07 Time 08:39 Sent To  
Notes
2021-09-07 08:40:15PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-08-17 Cont ID  
Sent By medwards Date 2021-08-17 Time 14:46 Rev Time 0.00
Received By medwards Date 2021-08-17 Time 14:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-07-14 Cont ID  
Sent By medwards Date 2021-07-14 Time 07:36 Rev Time 0.00
Received By medwards Date 2021-07-14 Time 07:33 Sent To  
Notes
2021-07-14 07:38:10PLEASE PROVIDE DIGITALLY SIGNED DRAWINGS OR YOU MAY
 BRING TO OUR OFFICE ORIGINAL SIGNED AND SEALED PAPER
 DRAWINGS.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-06-03 Cont ID  
Sent By jesmith Date 2021-06-03 Time 17:04 Rev Time 0.00
Received By jesmith Date 2021-06-03 Time 17:04 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved