Plan Review Details - Permit 21041163
Plan Review Stops For Permit 21041163
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-08-21 Cont ID  
Sent By shill Date 2021-08-21 Time 08:31 Rev Time 0.00
Received By shill Date 2021-08-21 Time 08:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-05-17 Cont ID  
Sent By cthroop Date 2021-05-17 Time 14:46 Rev Time 0.00
Received By cthroop Date 2021-05-17 Time 14:37 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2021-09-02 Cont ID  
Sent By fmittner Date 2021-09-02 Time 13:56 Rev Time 0.00
Received By fmittner Date 2021-09-02 Time 13:56 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2021-05-17 Cont ID  
Sent By aborngra Date 2021-05-17 Time 10:06 Rev Time 0.00
Received By aborngra Date 2021-05-14 Time 14:51 Sent To  
Notes
2021-05-17 10:06:26THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. PROVIDE A GRAPHIC OF THE PROPOSED FRONT DOOR. DOOR
 SHOULD BE SIMPLE IN NATURE WITH 2, 4, OR 6 PANELS. IF
 GLASS IS DESIRED, TOP 1/4 MAY HAVE GLASS WITH A 4-LITE
 PATTERN. MUNTINS MUST BE EXTERNAL AND DIMENSIONAL.
 2. REVISE WINDOWS #2, #3, #4, AND #5 TO A PAIRED
 CASEMENT WITH HORIZONTAL 3-LITES. ENSURE MUNTINS HAVE
 AN EXTERNAL PYRAMID PROFILE.
 3. REVISE WINDOW #6 TO BE A CASEMENT-FIXED-CASEMENT
 WITH MATCHING PROPORTIONS OF THE EXISTING WINDOW. EACH
 CASEMENT SHALL HAVE A HORIZONTAL 4-LITE WITH AN
 EXTERNAL PYRAMID PROFILE. AN XOX WITH MATCHING
 PROPORTIONS MAY WORK IN THIS WINDOW IF THE SCREENS ARE
 NOT INSTALLED AND KEPT ON-SITE AND USED AS NEEDED.
 4. INDICATE GLASS GLAZING AND FRAME COLOR. STREET
 FACING GLASS MUST BE CLEAR. NON-STREET GLASS MAY BE
 CLEAR OR CLEAR WITH LOW-E. EXTERIOR FRAME COLORS SHALL
 BE WHITE OR ANODIZED.
 5. INCLUDE THE ORDER QUOTE DETAIL/DETAILED CUSTOMER
 PROPOSAL.
  
 PROPOSED CONDITIONS, SUBJECT TO CHANGE:
 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE
 ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND
 MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL
 WINDOWS.
 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED
 WITH A MULLION OF MATCHING WIDTH AND PLACEMENT.
 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR.
 ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR
 WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS
 MAY BE USED ON NON-STREET FACING BATHROOMS ONLY.
  
 AARON BORNGRABER, AICP
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-03 Cont ID  
Sent By lmarchan Date 2021-09-03 Time 09:10 Rev Time 0.00
Received By lmarchan Date 2021-08-09 Time 09:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-17 Cont ID  
Sent By cthroop Date 2021-05-17 Time 14:46 Rev Time 0.00
Received By cthroop Date 2021-05-05 Time 16:38 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-05-17 Cont ID  
Sent By cthroop Date 2021-05-17 Time 14:46 Rev Time 0.00
Received By cthroop Date 2021-05-17 Time 14:37 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved