Plan Review Details - Permit 21041092
Plan Review Stops For Permit 21041092
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2021-10-19 Cont ID  
Sent By pvalenti Date 2021-10-19 Time 09:56 Rev Time 0.00
Received By jwitmer Date 2021-10-19 Time 09:55 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-08-18 Cont ID  
Sent By pvalenti Date 2021-08-18 Time 07:59 Rev Time 0.00
Received By pvalenti Date 2021-08-18 Time 06:58 Sent To  
Notes
2021-08-18 08:00:08****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 ASBESTOS REQUIREMENTS:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-06-03 Cont ID  
Sent By jwitmer Date 2021-06-03 Time 09:45 Rev Time 0.00
Received By jwitmer Date 2021-06-03 Time 09:31 Sent To  
Notes
2021-06-03 09:45:10COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-10-19 Cont ID  
Sent By jwitmer Date 2021-10-19 Time 10:04 Rev Time 0.00
Received By jwitmer Date 2021-10-19 Time 09:54 Sent To  
Notes
2021-10-19 10:04:44SHEET A-1
 BUUILDING PROVISO:
 603.3 MIRRORS. 2020 FBC-ACCESSIBILITY CODE. MIRRORS
 LOCATED ABOVE LAVATORIES
 OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE
 OF THE REFLECTING SURFACE
 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-08-18 Cont ID  
Sent By pvalenti Date 2021-08-18 Time 07:41 Rev Time 0.00
Received By pvalenti Date 2021-08-18 Time 06:59 Sent To  
Notes
2021-08-18 07:54:23****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 AS NOTED ON LAST REVIEW (ITEM 1D) PLEASE CORRECT THE
 FOLLOWING:
 FBC A 603.3, SHEET A-1 HAS THE CORRECT NOTES UNDER
 HANDICAPPED REQUIREMENTS. HOWEVER, THE LOCATION OF THE
 MIRROR INDICATED IN THE TYPICAL HANDICAPPED ACCESSIBLE
 DETAILS IS NOT CLEAR. PLEASE ADJUST THE LOCATION OF THE
 MIRROR TO SHOW THE BOTTOM LINES UP WITH THE 40" MARK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-06-03 Cont ID  
Sent By jwitmer Date 2021-06-03 Time 9:59 Rev Time 0.00
Received By jwitmer Date 2021-06-03 Time 09:31 Sent To  
Notes
2021-06-03 09:59:06WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21041092
 ADD: 2465 MERCER AVE. ## 103
 CONT: PHILIP E JOHNSON INC.
 TEL: 561-366-1034
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. JUNE 03/2021
 ACTION: DENIED
 1) SHEET A-1, HANDICAPPED BATHROOM REQUIREMENTS:
 1A) RAILS ASSUMED GRAB RAILS STATE AT 36 INCHES HIGH,
 IT IS NOT CLEAR WHERE THE MEASUREMENT IS TAKEN CENTER
 LINE OR TOP OF THE GRASPING SURFACE. 2020
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 1B) 2021 FBC-ACCESSIBILITY CODE SECTION 604.5.1 THE
 SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM) LONG
 MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE
 REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM
 FROM THE REAR WALL.
  
 1C) 2021 FBC-ACCESSIBILITY CODE SECTION 604.5.2 REAR
 WALL. THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915
 MM) LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE
 WATER CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND
 24 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
  
 1D) BATH ACCESSORIES STATES 40 INCHES ABOVE FINISH
 FLOOR MINIMUM 29 INCHES CLEAR OPENING. NOT SURE WHAT
 THIS IS FOR, POSSIBLE MEDICINE CABINET. 2021
 FBC-ACCESSIBILITY CODE. MIRRORS LOCATED ABOVE
 LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
 BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND.
  
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-08-24 Cont ID  
Sent By jleahy Date 2021-08-24 Time 13:58 Rev Time 0.00
Received By jleahy Date 2021-08-24 Time 13:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2021-05-26 Cont ID  
Sent By equinone Date 2021-05-26 Time 15:51 Rev Time 0.00
Received By equinone Date 2021-05-26 Time 15:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-08-10 Cont ID  
Sent By cwalker Date 2021-08-10 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-05-21 Cont ID  
Sent By cwalker Date 2021-05-21 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-11-20 Cont ID  
Sent By lmarchan Date 2021-11-20 Time 08:32 Rev Time 0.00
Received By lmarchan Date 2021-11-15 Time 09:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-10-19 Cont ID  
Sent By jwitmer Date 2021-10-19 Time 10:05 Rev Time 0.00
Received By jwitmer Date 2021-10-08 Time 12:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-08 Cont ID  
Sent By aoliver Date 2021-10-08 Time 09:27 Rev Time 0.00
Received By aoliver Date 2021-10-08 Time 08:04 Sent To  
Notes
2021-10-08 09:28:10MISTAKE, SOME DOCUMENTS UPLOADED W ERRORS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-24 Cont ID  
Sent By jleahy Date 2021-08-24 Time 13:58 Rev Time 0.00
Received By jleahy Date 2021-08-09 Time 16:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-03 Cont ID  
Sent By jwitmer Date 2021-06-03 Time 09:59 Rev Time 0.00
Received By jwitmer Date 2021-05-14 Time 16:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2021-11-19 Cont ID  
Sent By medwards Date 2021-11-19 Time 11:58 Rev Time 0.00
Received By medwards Date 2021-11-19 Time 11:58 Sent To  
Notes
2021-11-19 11:59:10APPROVED WITH PRIVISO:
 THE BATH EXHAUST LOUVER ABOVE THE EXTERIOR DOOR SHALL
 BE A MINIMUM OF 3' AWAY FROM THE OPENING OF THE DOOR.
 FBC M 501.3 (3) ME

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2021-10-13 Cont ID  
Sent By medwards Date 2021-10-13 Time 14:30 Rev Time 0.00
Received By medwards Date 2021-10-13 Time 14:30 Sent To  
Notes
2021-10-13 14:34:49PLEASE PROVIDE A MECHANICAL DRAWING SHOWING THE EXHAUST
 FAN, EXHAUST DUCT AND TERMINATION LOCATION OF THE
 EXHAUST FOR THIS NEW BATHROOM.
 PLEASE SHOW THE SUPPLY AIR DUCTWORK AND GRILLE FOR THIS
 NEW BATHROOM.
 THE A SHEETS HAVE A DETAIL OF A CONDENSING UNIT AND A
 SLAB. REMOVE THIS DETAIL IF THERE WILL NOT BE A NEW
 MECHANICAL SYSTEM INSTALLED AT THIS LOCATION. IF THERE
 IS GOING TO BE NEW MECHANICAL SYSTEM INSTALLED AT THIS
 LOCATION THEN PROVIDE A MECHANICAL DRAWING SHOWING THIS
 AND THE UNIT INFORMATION. FBC 107.2.1
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2021-08-20 Cont ID  
Sent By medwards Date 2021-08-20 Time 14:06 Rev Time 0.00
Received By medwards Date 2021-08-20 Time 14:06 Sent To  
Notes
2021-08-20 14:06:331ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21041092
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THERE IS NO A-4 SHEET. THERE IS AN A-5 SHEET THAT
 SHOWS A DETAIL OF AN AHU MOUNTING DETAIL AND A
 CONDENSING UNIT PAD DETAIL. PROVIDE A MECHANICAL
 DRAWING THAT SHOWS THE LOCATIONS OF THIS EQUIPMENT. IS
 THIS A LIKE FOR LIKE CHANGE OUT? IF SO PLEASE FILL OUT
 THE LIKE FOR LIKE FORM IN ITS ENTIRETY. PLEASE PROVIDE
 A SCOPE OF WORK FOR THE MECHANICAL WORK BEING COMPLETED
 UNDER THIS PERMIT. FBC 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-05-28 Cont ID  
Sent By medwards Date 2021-05-28 Time 08:38 Rev Time 0.00
Received By medwards Date 2021-05-28 Time 08:30 Sent To  
Notes
2021-05-28 08:39:021ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21041092
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE MECHANICAL DRAWING SHOWING THE
 EXHAUST FAN, DUCTWORK AND TERMINATION LOCATION. PLEASE
 ALSO SHOW THE SPECIFICATIONS FOR THE EXHAUST FAN. FBC M
 TABLE 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-08-20 Cont ID  
Sent By ccole Date 2021-08-20 Time 17:13 Rev Time 0.00
Received By ccole Date 2021-08-20 Time 16:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-02 Cont ID  
Sent By ccole Date 2021-06-02 Time 16:50 Rev Time 0.00
Received By ccole Date 2021-06-02 Time 15:36 Sent To  
Notes
2021-06-02 16:51:071ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21041092
 6/2/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE COMPLETE PLUMBING PLANS AND SPECIFICATIONS
 FOR THE PROPOSED NEW TOILET ROOM- SECTIONS 107.2.1 &
 107.3.5.3.1 WPB. PLEASE INCLUDE THE FOLLOWING ITEMS:
 A) PLUMBING FLOOR PLAN LAYOUT DRAWING.
 B) SANITARY AND WATER ISOMETRIC DRAWINGS.
 C) FIXTURE AND DEVICE SCHEDULES.
 D) PIPING SPECIFICATIONS.
 E) SLAB REPAIR DETAIL.
  
 2) REFER TO TABLE 403.1 FBC P AND PROVIDE PLUMBING
 FIXTURE CALCULATIONS. PROVIDE A SCHEDULE THAT INDICATES
 THE REQUIRED AND PROVIDED NUMBER OF PLUMBING FIXTURES.
 PLEASE NOTE THAT A SERVICE SINK IS A REQUIRED FIXTURE
 FOR BUSINESS OCCUPANCIES. IS THERE CURRENTLY A SERVICE
 SINK IN USE FOR THE OCCUPANCY? PLEASE SHOW THE LOCATION
 ON THE PLAN.
  
 3) SHEET A-1: REFER TO FIGURES 306.2 & 306.3 FBC ACC
 AND PROVIDE THE NEW LAVATORY KNEE AND TOE CLEARANCES.
  
 4) A-1: THE GRAB BARS SHALL BE POSITIONED A MAXIMUM OF
 36 INCHES ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACES- SECTION 609.4 FBC ACC. PLEASE
 CORRECT THE DRAWING SHOWING THE MEASUREMENT TO THE
 CENTER OF THE BARS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-11-19 Cont ID  
Sent By medwards Date 2021-11-19 Time 12:01 Rev Time 0.00
Received By medwards Date 2021-11-19 Time 12:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-10-19 Cont ID  
Sent By jwitmer Date 2021-10-19 Time 10:05 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-08-18 Cont ID  
Sent By pvalenti Date 2021-08-18 Time 08:01 Rev Time 0.00
Received By pvalenti Date 2021-08-18 Time 08:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-05-28 Cont ID  
Sent By medwards Date 2021-05-28 Time 08:40 Rev Time 0.00
Received By medwards Date 2021-05-28 Time 08:39 Sent To  
Notes
***NONE***