Plan Review Stops For Permit 21041092 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-10-19 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-10-19 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2021-08-18 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-08-18 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-08-18 |
Time |
06:58 |
Sent To |
|
|
Notes |
2021-08-18 08:00:08 | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | ASBESTOS REQUIREMENTS: | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2021-06-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-06-03 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-06-03 |
Time |
09:31 |
Sent To |
|
|
Notes |
2021-06-03 09:45:10 | COMMERCIAL ASBESTOS | | TO THE BUILDING CONTRACTOR: | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-10-19 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-10-19 |
Time |
09:54 |
Sent To |
|
|
Notes |
2021-10-19 10:04:44 | SHEET A-1 | | BUUILDING PROVISO: | | 603.3 MIRRORS. 2020 FBC-ACCESSIBILITY CODE. MIRRORS | | LOCATED ABOVE LAVATORIES | | OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE | | OF THE REFLECTING SURFACE | | 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-08-18 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-08-18 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-08-18 |
Time |
06:59 |
Sent To |
|
|
Notes |
2021-08-18 07:54:23 | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | BUILDING REVIEW DENIED: | | | | AS NOTED ON LAST REVIEW (ITEM 1D) PLEASE CORRECT THE | | FOLLOWING: | | FBC A 603.3, SHEET A-1 HAS THE CORRECT NOTES UNDER | | HANDICAPPED REQUIREMENTS. HOWEVER, THE LOCATION OF THE | | MIRROR INDICATED IN THE TYPICAL HANDICAPPED ACCESSIBLE | | DETAILS IS NOT CLEAR. PLEASE ADJUST THE LOCATION OF THE | | MIRROR TO SHOW THE BOTTOM LINES UP WITH THE 40" MARK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-06-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-06-03 |
Time |
9:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-06-03 |
Time |
09:31 |
Sent To |
|
|
Notes |
2021-06-03 09:59:06 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21041092 | | ADD: 2465 MERCER AVE. ## 103 | | CONT: PHILIP E JOHNSON INC. | | TEL: 561-366-1034 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. JUNE 03/2021 | | ACTION: DENIED | | 1) SHEET A-1, HANDICAPPED BATHROOM REQUIREMENTS: | | 1A) RAILS ASSUMED GRAB RAILS STATE AT 36 INCHES HIGH, | | IT IS NOT CLEAR WHERE THE MEASUREMENT IS TAKEN CENTER | | LINE OR TOP OF THE GRASPING SURFACE. 2020 | | FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB | | BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE | | THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING | | SURFACE, NOT CENTERLINE. | | | | 1B) 2021 FBC-ACCESSIBILITY CODE SECTION 604.5.1 THE | | SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM) LONG | | MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE | | REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM | | FROM THE REAR WALL. | | | | 1C) 2021 FBC-ACCESSIBILITY CODE SECTION 604.5.2 REAR | | WALL. THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 | | MM) LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE | | WATER CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND | | 24 INCHES (610 MM) MINIMUM ON THE OTHER SIDE. | | | | 1D) BATH ACCESSORIES STATES 40 INCHES ABOVE FINISH | | FLOOR MINIMUM 29 INCHES CLEAR OPENING. NOT SURE WHAT | | THIS IS FOR, POSSIBLE MEDICINE CABINET. 2021 | | FBC-ACCESSIBILITY CODE. MIRRORS LOCATED ABOVE | | LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE | | BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES MAXIMUM | | ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | RETIRED. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-08-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-24 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-24 |
Time |
13:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2021-05-26 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-05-26 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-05-26 |
Time |
15:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2021-08-10 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2021-08-10 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2021-05-21 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2021-05-21 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2021-11-20 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-11-20 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-11-15 |
Time |
09:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-10-19 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-10-08 |
Time |
12:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-10-08 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2021-10-08 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-10-08 |
Time |
08:04 |
Sent To |
|
|
Notes |
2021-10-08 09:28:10 | MISTAKE, SOME DOCUMENTS UPLOADED W ERRORS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-08-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-24 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-09 |
Time |
16:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-06-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-06-03 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-05-14 |
Time |
16:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2021-11-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-11-19 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-11-19 |
Time |
11:58 |
Sent To |
|
|
Notes |
2021-11-19 11:59:10 | APPROVED WITH PRIVISO: | | THE BATH EXHAUST LOUVER ABOVE THE EXTERIOR DOOR SHALL | | BE A MINIMUM OF 3' AWAY FROM THE OPENING OF THE DOOR. | | FBC M 501.3 (3) ME |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-10-13 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-10-13 |
Time |
14:30 |
Sent To |
|
|
Notes |
2021-10-13 14:34:49 | PLEASE PROVIDE A MECHANICAL DRAWING SHOWING THE EXHAUST | | FAN, EXHAUST DUCT AND TERMINATION LOCATION OF THE | | EXHAUST FOR THIS NEW BATHROOM. | | PLEASE SHOW THE SUPPLY AIR DUCTWORK AND GRILLE FOR THIS | | NEW BATHROOM. | | THE A SHEETS HAVE A DETAIL OF A CONDENSING UNIT AND A | | SLAB. REMOVE THIS DETAIL IF THERE WILL NOT BE A NEW | | MECHANICAL SYSTEM INSTALLED AT THIS LOCATION. IF THERE | | IS GOING TO BE NEW MECHANICAL SYSTEM INSTALLED AT THIS | | LOCATION THEN PROVIDE A MECHANICAL DRAWING SHOWING THIS | | AND THE UNIT INFORMATION. FBC 107.2.1 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2021-08-20 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-20 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-20 |
Time |
14:06 |
Sent To |
|
|
Notes |
2021-08-20 14:06:33 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-21041092 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THERE IS NO A-4 SHEET. THERE IS AN A-5 SHEET THAT | | SHOWS A DETAIL OF AN AHU MOUNTING DETAIL AND A | | CONDENSING UNIT PAD DETAIL. PROVIDE A MECHANICAL | | DRAWING THAT SHOWS THE LOCATIONS OF THIS EQUIPMENT. IS | | THIS A LIKE FOR LIKE CHANGE OUT? IF SO PLEASE FILL OUT | | THE LIKE FOR LIKE FORM IN ITS ENTIRETY. PLEASE PROVIDE | | A SCOPE OF WORK FOR THE MECHANICAL WORK BEING COMPLETED | | UNDER THIS PERMIT. FBC 107.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-05-28 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-05-28 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-05-28 |
Time |
08:30 |
Sent To |
|
|
Notes |
2021-05-28 08:39:02 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-21041092 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE MECHANICAL DRAWING SHOWING THE | | EXHAUST FAN, DUCTWORK AND TERMINATION LOCATION. PLEASE | | ALSO SHOW THE SPECIFICATIONS FOR THE EXHAUST FAN. FBC M | | TABLE 403.3.1.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-08-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-08-20 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-08-20 |
Time |
16:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-06-02 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-06-02 |
Time |
15:36 |
Sent To |
|
|
Notes |
2021-06-02 16:51:07 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 21041092 | | 6/2/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE COMPLETE PLUMBING PLANS AND SPECIFICATIONS | | FOR THE PROPOSED NEW TOILET ROOM- SECTIONS 107.2.1 & | | 107.3.5.3.1 WPB. PLEASE INCLUDE THE FOLLOWING ITEMS: | | A) PLUMBING FLOOR PLAN LAYOUT DRAWING. | | B) SANITARY AND WATER ISOMETRIC DRAWINGS. | | C) FIXTURE AND DEVICE SCHEDULES. | | D) PIPING SPECIFICATIONS. | | E) SLAB REPAIR DETAIL. | | | | 2) REFER TO TABLE 403.1 FBC P AND PROVIDE PLUMBING | | FIXTURE CALCULATIONS. PROVIDE A SCHEDULE THAT INDICATES | | THE REQUIRED AND PROVIDED NUMBER OF PLUMBING FIXTURES. | | PLEASE NOTE THAT A SERVICE SINK IS A REQUIRED FIXTURE | | FOR BUSINESS OCCUPANCIES. IS THERE CURRENTLY A SERVICE | | SINK IN USE FOR THE OCCUPANCY? PLEASE SHOW THE LOCATION | | ON THE PLAN. | | | | 3) SHEET A-1: REFER TO FIGURES 306.2 & 306.3 FBC ACC | | AND PROVIDE THE NEW LAVATORY KNEE AND TOE CLEARANCES. | | | | 4) A-1: THE GRAB BARS SHALL BE POSITIONED A MAXIMUM OF | | 36 INCHES ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | THE GRIPPING SURFACES- SECTION 609.4 FBC ACC. PLEASE | | CORRECT THE DRAWING SHOWING THE MEASUREMENT TO THE | | CENTER OF THE BARS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-11-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-11-19 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-11-19 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-10-19 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-08-18 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-08-18 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-08-18 |
Time |
08:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-05-28 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-05-28 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-05-28 |
Time |
08:39 |
Sent To |
|
|
Notes |
|
|