Plan Review Details - Permit 21041080
Plan Review Stops For Permit 21041080 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-01 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-01 |
Time |
11:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-05-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-11 |
Time |
07:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-11 |
Time |
07:54 |
Sent To |
|
|
Notes |
2021-05-11 08:00:16 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT GENERATOR PAD DRAWINGS WITH GENERATOR TO PAD | | ANCHORING DETAILS. IF A PREFABRICATED GENERATOR PAD | | WILL BE USED, SUBMIT SIGNED AND SEALED SITE SPECIFIC | | ENGINEERING FOR IT. FBC AMENDMENTS 107.2.1 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-06-25 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-06-25 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-06-25 |
Time |
14:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-05-11 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-05-11 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-05-11 |
Time |
09:46 |
Sent To |
|
|
Notes |
2021-05-11 10:06:41 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | RISER SHOWS 2/0'A FEEDING THE LOADS, BECAUSE THERE IS 2 | | PANELS THE FEEDER IS NOT FEEDING THE ENTIRE LOAD SO | | 3/0'S WILL BE REQUIRED. 310.15(B)(7)(2) | | | | 310.15(B)(7)(2) FOR A FEEDER RATED 100 THROUGH 400 | | AMPERES, THE FEEDER CONDUCTORS SUPPLYING THE ENTIRE | | LOAD ASSOCIATED WITH A ONE-FAMILY DWELLING, OR THE | | FEEDER CONDUCTORS SUPPLYING THE ENTIRE LOAD ASSOCIATED | | WITH AN INDIVIDUAL DWELLING UNIT IN A TWO-FAMILY OR | | MULTIFAMILY DWELLING, SHALL BE PERMITTED TO HAVE AN | | AMPACITY NOT LESS THAN 83 PERCENT OF THE FEEDER RATING. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-01 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-06-21 |
Time |
06:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-06-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-17 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-04-20 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-01 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-01 |
Time |
11:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-05-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-11 |
Time |
07:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-11 |
Time |
07:54 |
Sent To |
|
|
Notes |
2021-05-11 08:04:46 | SIGNATURE WILL NEED TO BE EVALUATED WHEN BUILDING | | COMMENTS ARE ADDRESSED. ELECTRONICALLY SUBMITTED | | DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT OR | | ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE | | OPTION TO SUBMIT THE SIGNED AND SEALED PAPER VERSION OF | | DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE BEEN | | APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE | | AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO | | PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE | | ACCEPTABLE. FS 487 & 61G1 OR FS 471 & 61G15 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-06-16 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-06-16 |
Time |
13:37 |
Sent To |
I |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy