Plan Review Details - Permit 21041063
Plan Review Stops For Permit 21041063
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-06-29 Cont ID  
Sent By cthroop Date 2021-06-29 Time 07:35 Rev Time 0.00
Received By cthroop Date 2021-06-29 Time 06:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-06-12 Cont ID  
Sent By cthroop Date 2021-06-12 Time 08:51 Rev Time 0.00
Received By cthroop Date 2021-06-12 Time 08:38 Sent To  
Notes
2021-06-12 08:53:17PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 1&2 FAMILY - SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: SHUTTER SCHEDULE
  
 1. SPECIFY FASTENER TYPE FROM PRODUCT APPROVAL FASTENER
 SCHEDULE.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-06-10 Cont ID  
Sent By aborngra Date 2021-06-10 Time 11:09 Rev Time 0.00
Received By aborngra Date 2021-06-10 Time 11:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-29 Cont ID  
Sent By cthroop Date 2021-06-29 Time 07:37 Rev Time 0.00
Received By cthroop Date 2021-06-14 Time 15:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-12 Cont ID  
Sent By cthroop Date 2021-06-12 Time 08:57 Rev Time 0.00
Received By cthroop Date 2021-05-26 Time 14:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2021-08-10 Cont ID  
Sent By cthroop Date 2021-08-10 Time 11:02 Rev Time 0.00
Received By cthroop Date 2021-08-10 Time 11:02 Sent To  
Notes
2021-08-10 11:03:228/10/21 CONTRACTOR REQUESTED DESIGN CALC'S BE LOCKED.
 NOT REQUIRED FOR RESIDENTIAL. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-06-29 Cont ID  
Sent By cthroop Date 2021-06-29 Time 07:35 Rev Time 0.00
Received By cthroop Date 2021-06-29 Time 06:46 Sent To  
Notes
2021-06-29 07:36:56PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 2ND REVIEW
 RESULTS: DENIED (COMMENTS FROM 1ST REVIEW HAVE NOT BEEN
 CORRECTED)
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
 RE: ASCE 7-16
  
 1. DESIGN WIND PRESSURES WERE PREPARED BY A DESIGN
 PROFESSIONAL. A VALID DIGITAL SIGNATURE IS REQUIRED.
 (SEE #2 ABOVE)
  
 NOTICE: FOR RESIDENTIAL PROPERTIES, DESIGN WIND
 PRESSURES CAN BE PREPARED AND SUBMITTED BY THE
 CONTRACTOR. A DESIGN PROFESSIONAL IS NOT REQUIRED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-06-12 Cont ID  
Sent By cthroop Date 2021-06-12 Time 08:53 Rev Time 0.00
Received By cthroop Date 2021-06-12 Time 08:53 Sent To  
Notes
2021-06-12 08:57:40PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 1ST REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
 RE: ASCE 7-16
  
 1. DESIGN WIND PRESSURES WERE PREPARED BY A DESIGN
 PROFESSIONAL. A VALID DIGITAL SIGNATURE IS REQUIRED.
 (SEE #2 ABOVE)
  
 NOTICE: FOR RESIDENTIAL PROPERTIES, DESIGN WIND
 PRESSURES CAN BE PREPARED AND SUBMITTED BY THE
 CONTRACTOR. A DESIGN PROFESSIONAL IS NOT REQUIRED.


Account Summary | Usage Policy | Privacy Policy