Plan Review Details - Permit 21040797
Plan Review Stops For Permit 21040797 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-05-26 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-05-26 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-05-26 |
Time |
07:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-05-21 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-05-21 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-05-20 |
Time |
07:50 |
Sent To |
|
|
Notes |
2021-05-21 12:55:44 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | FL14083-R26 IS INCOMPLETE, PROVIDE THE FOLLOWING | | ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-5 TO | | INCLUDE LIMITATIONS PAGE(S). | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-04-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-04-16 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-04-16 |
Time |
07:26 |
Sent To |
|
|
Notes |
2021-04-16 08:51:33 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY, THURSDAY & FRIDAY 7:00 AM TO 3:00 | | PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. SUBMITTED PRODUCT APPROVAL FL16440-R21 HAS BEEN | | REVISED TO FL16440-R22. PLEASE PROVIDE A COMPLETE SET | | INCLUDING EVALUATION REPORTS PAGES 1-5 WITH LIMITATION | | PAGE(S). ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN | | PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | AS PER RULE 61G20-3. | | 2. FBC EB 706.3(1) PROVIDE A SIGNED AND SEALED MOISTURE | | REPORT PREPARED BY A FLORIDA REGISTERED DESIGN | | PROFESSIONAL. | | 3. PROVIDE FIELD UPLIFT TESTING IN ACCORDANCE WITH | | TESTING APPLICATION STANDARD TAS 124 AS REQUIRED BY | | LIMITATIONS 5.6.3 OF PRODUCT APPROVAL FL16440. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-05-26 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-05-26 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-05-25 |
Time |
11:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-05-21 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-05-21 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-05-18 |
Time |
07:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-04-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-04-16 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-04-15 |
Time |
07:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-05-26 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-05-26 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-05-26 |
Time |
07:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-05-21 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-05-21 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-05-20 |
Time |
07:50 |
Sent To |
|
|
Notes |
2021-05-21 12:54:52 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | PETER VALENTI | | BUILDING PLANS EXAMINER II | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6673. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-04-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-04-16 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-04-16 |
Time |
08:50 |
Sent To |
|
|
Notes |
2021-04-16 08:52:20 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY, THURSDAY & FRIDAY 7:00 AM TO 3:00 | | PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | PETER VALENTI | | BUILDING PLANS EXAMINER II | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6673. | | |
|
|
|