Plan Review Stops For Permit 21031623 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2021-12-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-12-01 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-30 |
Time |
16:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-11-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-11-09 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-09 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-15 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-13 |
Time |
13:41 |
Sent To |
|
|
Notes |
2021-10-15 16:30:27 | PLAN REVIEW BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 3RD REVIEW - MAIN DWELLING UNIT (INCLUDING EXISTING | | ACCESS. STRUCTURE) | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE #1: | | PROVISO ON SITE PLAN A0.0: SEPERATE PERMIT REQUIRED FOR | | SITE WALLS. | | | | | | NOTICE #2: | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA). IT IS LOCATED IN ZONE AE WITH A BASE FLOOD | | ELEVATION OF 6.0 FEET NAVD. BASED ON THE VALUE OF THIS | | SUBMITTAL, THE WORK ON THE PROPERTY IS CONSIDERED A | | SUBSTANTIAL IMPROVEMENT (S/I) PER FEMA P-758. | | | | 2020 FBC EXISTING BUILDING | | 1201.3FLOOD HAZARD AREAS. | | IN FLOOD HAZARD AREAS, IF ALL PROPOSED WORK, INCLUDING | | REPAIRS, WORK REQUIRED BECAUSE OF A CHANGE OF | | OCCUPANCY, AND ALTERATIONS, CONSTITUTES SUBSTANTIAL | | IMPROVEMENT, THEN THE BUILDING SHALL COMPLY WITH | | SECTION 1612 OF THE FLORIDA BUILDING CODE, BUILDING, OR | | SECTION R322 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, | | AS APPLICABLE. | | | | CITY ORDINANCE NO. 4658-16 | | | | CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16 | | AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT | | AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE | | MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD | | HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM | | BEACH, FL. | | | | ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON | | NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM | | BEACH, BY ORDINANCE, NO. 4658-16, ESTABLISHED A | | TWO-FOOT FREEBOARD ABOVE THE (BFE). | | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION | | PLAN AND/OR FLOOR PLAN. | | | | | | NOTICE #3: | | A FLOOD VARIANCE APPLICATION AND NOTICE OF HEARING HAVE | | BEEN SUBMITTED FOR REVIEW. STATUS OF PROJECT REMAINS | | UNCHANGED UNTIL A LETTER OF APPROVAL HAS BEEN SUBMITTED | | FOR REVIEW. | | | | 1. FINISHED FLOOR ELEVATION OF MAIN DWELLING UNIT | | INCLUDING THE EXISTING ACCESSORY STRUCTURE CONVERTED TO | | A CABANA SHALL BE AT OR ABOVE THE DFE OF 8.0' NAVD. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-09-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-09-09 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-09-08 |
Time |
14:32 |
Sent To |
|
|
Notes |
2021-09-09 11:18:07 | PLAN REVIEW BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 2ND REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: | | PROVISO ON SITE PLAN A0.0: SEPERATE PERMIT REQUIRED FOR | | SITE WALLS. | | | | 1. FINISHED FLOOR ELEVATIONS ARE INCORRECT ON SITE | | DRAINAGE PLAN. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2. EXISTING TWO STORY RESIDENCE, NEW ADDITION AND | | EXISTING ACCESS. STRUCTURE WILL BE UNDER ONE ROOF. | | PROVIDE A ROOF FRAMING PLAN. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-04-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-27 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-26 |
Time |
14:36 |
Sent To |
|
|
Notes |
2021-04-27 10:54:21 | PLAN REVIEW BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: A SEPERATE PERMIT IS REQUIRED FOR THE FREE | | STANDING GARAGE. SUBMIT PERMIT APPLICATION TO | | [email protected]. ALL PLANS WILL REMAIN UNDER | | PERMIT 21030623. | | PERMITS - 105.1 REQUIRED. | | | | NOTICE: STRUCTURES ARE LOCATED IN A SPECIAL FLOOD | | HAZARD AREA (SFHA). DESIGN SHALL BE BY FBC CHPT 16 | | AND/OR FBR R322. | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS TO THE PLANS: | | | | 1. CORRECT GOVERNING CODE ON MECH., ELECTRICAL AND | | PLUMBING PLANS. | | 2. PAGE GN STATES ADDITION SHALL BE 980 SF. PAGE A0.0 | | SITE PLAN STATES ADDITION SHALL BE 1568 SF. PLEASE | | CLARIFY. | | 3. SEE PAGE A0.0 SITE PLAN FOR THE FOLLOWING: | | 3A. NOTES STATE LOWEST SLAB SHALL BE 18" ABOVE CROWN OF | | ROAD. | | R403.1.7.3 FOUNDATION ELEVATION. | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | PERCENT. | | 3B. SITE AREA CALCULATIONS STATE FLOOD ZONE IS A5 AND | | MIN. FLOOD ELEVATION IS 7.0 FT | | THIS PROPERTY IS IN FLOOD ZONE AE WITH A BASE FLOOD | | ELEVATION OF 6.0 FEET. CITY ORDINACE REQUIRES 2 FEET OF | | FREE BOARD FOR A DESIGN FLOOD ELEVATION OF 8.0 FEET | | NAVD88. | | | | REVIEW COMMENTS AS FOLLOWS: | | | | 4. PROVIDE A SOILS REPORT FOR THE GARAGE AREA. | | 1803.2 INVESTIGATIONS REQUIRED. | | GEOTECHNICAL INVESTIGATIONS SHALL BE CONDUCTED IN | | ACCORDANCE WITH SECTIONS 1803.3 THROUGH 1803.5. | | | | 5. PROVIDE CURRENT BOUNDRY LINE SURVEY. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 6. PROVIDE A SITE DRAINAGE PLAN. | | FBC R401.3 SITE DRAINAGE | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | FBC R401.3 DRAINAGE. | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | DOES NOT CREATE A HAZARD. | | | | 7. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 8. PROVIDE ICC-ES REPORT FOR PROPOSED R-20 SPRAY FOAM | | INSULATION. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-08-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-24 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-24 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-08 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-08 |
Time |
16:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-08 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-08 |
Time |
16:01 |
Sent To |
|
|
Notes |
2021-04-08 16:01:50 | PHONE DATA AND TV JLEAHY |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-08-21 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-08-21 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-08-21 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-04-19 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-04-19 |
Time |
21:15 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-04-19 |
Time |
18:53 |
Sent To |
|
|
Notes |
2021-04-19 20:49:32 | 1ST REVIEW FBC-2020 GAS | | PERMIT-21031623 | | 4/19/2021 | | | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE SEVENTH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SEVENTH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE SEVENTH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE SEVENTH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE SEVENTH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SEVENTH | | EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE SEVENTH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SEVENTH | | EDITION 2020 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1- PLEASE INDICATE ON THE PLANS IN ALL AREAS THE MOST | | CURRENT CODE CYCLE. THE CURRENT CODE CYCLE IS FBC 2020 | | 2- SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2020 | | FBC FUEL GAS SEC. 304.1, 614.5 (CLOTHES DRYERS) OR 2020 | | FBC FUEL GAS RES. SEC. G2407.1 AND G2439.4 (CLOTHES | | DRYERS). | | 3- SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | INSTALLATION. 2020 FBC FUEL GAS SEC.410.1 OR 2020 FBC | | FUEL GAS RES. SEC. G2421.1. | | 4- 2ND STAGE REGULATORS REQUIRED ON TANKLESS WATER | | HEATERS PER MANUFACTURES MAX GAS INLET PRESSURE | | 5- ON PLAN PAGE P2 COMENT IN CENTER OF GAS RISER: UNDER | | CONCRETE SLAB SCH 40 METALIC PIPE SHALL BE REMOVED FROM | | THE PLAN PER FBC FG 2020 SEC.404.14PIPING UNDERGROUND | | BENEATH BUILDINGS. | | PIPING INSTALLED UNDERGROUND BENEATH BUILDINGS IS | | PROHIBITED | | 6- SUBMIT COMPLETE MANUFACTURER'S SPECIFICATIONS FOR | | THE GAS DRYER. THE GAS DRYER SHALL BE LISTED AND | | LABELED PER THE 2020 FBC FUEL GAS SEC.301.3 OR 2020 FBC | | FUEL GAS RES. SEC. G2404.3. THE MANUFACTURER'S | | SPECIFICATIONS SHALL NOTE THE CFM'S THAT ARE BEING | | EXHAUSTED BY THE DRYER. | | 7- A GAS GRILL IS LABELED FOR OUTSIDE USE AND IT SEEMS | | TO BE IN A COVERED PATIO, IF SO PLEASE PROVIDE | | MANUFACTURES RECOMMENDATION FOR A VENTILATION HOOD, | | 2020 FBC FG SEC.G2408.1. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | ATELYO BELISLE | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6695 | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2021-04-23 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-04-23 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-04-23 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2021-12-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-12-01 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-30 |
Time |
11:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-11-10 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-11-10 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-10-27 |
Time |
07:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-10-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-16 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-06 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-09-10 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-09-10 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-08-09 |
Time |
12:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-04-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-27 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-06 |
Time |
17:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-11-30 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-11-30 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-11-10 |
Time |
15:43 |
Sent To |
|
|
Notes |
2021-11-16 15:02:51 | RECEIPT MU-2021-054189 - $22.46 PAID | 2021-11-10 15:43:36 | 11/10/21 EMAILED IMPACT TO REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-04-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-26 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-26 |
Time |
16:20 |
Sent To |
|
|
Notes |
2021-04-26 16:21:04 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-08-20 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-20 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-20 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-04-12 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-04-12 |
Time |
08:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
4 |
Status |
N |
Date |
2021-11-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-11-09 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-09 |
Time |
10:19 |
Sent To |
|
|
Notes |
2021-11-09 14:48:06 | CBAA FLOOD VARIANCE APPROVED ON 10/27/2021. CT SEE | | PERMIT 21090994. |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
3 |
Status |
F |
Date |
2021-10-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-16 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-13 |
Time |
13:41 |
Sent To |
|
|
Notes |
2021-10-16 10:41:52 | NFIP PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | CITY ORDINANCE NO. 4658-16 | | | | 3RD REVIEW | | | | RE: CONSTRUCTION DRFAWING ELEVATION CERTIFICATE | | | | RESULTS: DENIED | | | | NOTICE: | | | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA). IT IS LOCATED IN ZONE AE WITH A BASE FLOOD | | ELEVATION OF 6.0 FEET NAVD. BASED ON THE VALUE OF THIS | | SUBMITTAL, THE WORK ON THE PROPERTY IS CONSIDERED A | | SUBSTANTIAL IMPROVEMENT (S/I) PER FEMA P-758. | | | | 2020 FBC EXISTING BUILDING | | 1201.3FLOOD HAZARD AREAS. | | IN FLOOD HAZARD AREAS, IF ALL PROPOSED WORK, INCLUDING | | REPAIRS, WORK REQUIRED BECAUSE OF A CHANGE OF | | OCCUPANCY, AND ALTERATIONS, CONSTITUTES SUBSTANTIAL | | IMPROVEMENT, THEN THE BUILDING SHALL COMPLY WITH | | SECTION 1612 OF THE FLORIDA BUILDING CODE, BUILDING, OR | | SECTION R322 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, | | AS APPLICABLE. | | | | CITY ORDINANCE NO. 4658-16 | | | | CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16 | | AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT | | AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE | | MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD | | HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM | | BEACH, FL. | | | | ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON | | NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM | | BEACH, BY ORDINANCE, NO. 4658-16, ESTABLISHED A | | TWO-FOOT FREEBOARD ABOVE THE (BFE). | | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION | | PLAN AND/OR FLOOR PLAN. | | | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA) WITH A BASE FLOOD ELEVATION (BFE) OF 6.0' NAVD. | | DESIGN FLOOD ELEVATION (DFE) SHALL BE 8.0' NAVD OR | | HIGHER. | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT: | | | | 1. LINE A7- BLDG. DIAGRAM NUMBER SHOULD BE 1B. | | | | 2. LINE A8- THERE IS NO INDICATION ON THE PLANS | | SUBMITTED FOR REVIEW THAT THE BUILDING HAS A CRAWL | | SPACE. | | | | 3. LINE C1- THIS IS THE CONSTRUCTION DRAWING ELEVATION | | CERTIFICATE, NOT THE FINISHED CONSTRUCTION EC. | | | | 4. LINES C2 A THRU H)- ENTER DATA CONSISTANT WITH THE | | DFE OF 8.0' NAVD. | | | | 5. SECTION D COMMENTS- COMMENTS SHALL BE CONSISTANT | | WITH THE DFE OF 8.0'NAVD. | | | | NOTICE: THIS PROPERTY IS LOCATED IN A HISTORIC | | DISTRICT. OWNERS HAVE SUBMITTED APPLICATION TO THE | | CONSTRUCTION BOARD OF ADJUSTMENTS AND APPEALS (CBAA) | | FOR A FLOOD VARIANCE. | | NOH ON 10-21-2021. | | | | | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
F |
Date |
2021-09-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-09-09 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-09-08 |
Time |
14:31 |
Sent To |
|
|
Notes |
2021-09-09 11:23:49 | PLAN REVIEW / NFIP | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | CITY ORDINANCE NO. 4658-16 | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | 1ST REVIEW COMMENTS HAVE NOT BEEN ADDRESSED. | | | | NOTICE: | | | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA). IT IS LOCATED IN ZONE AE WITH A BASE FLOOD | | ELEVATION OF 6.0 FEET NAVD. BASED ON THE VALUE OF THIS | | SUBMITTAL, THE WORK ON THE PROPERTY IS CONSIDERED A | | SUBSTANTIAL IMPROVEMENT (S/I) PER FEMA P-758. | | | | 2020 FBC EXISTING BUILDING | | 1201.3FLOOD HAZARD AREAS. | | IN FLOOD HAZARD AREAS, IF ALL PROPOSED WORK, INCLUDING | | REPAIRS, WORK REQUIRED BECAUSE OF A CHANGE OF | | OCCUPANCY, AND ALTERATIONS, CONSTITUTES SUBSTANTIAL | | IMPROVEMENT, THEN THE BUILDING SHALL COMPLY WITH | | SECTION 1612 OF THE FLORIDA BUILDING CODE, BUILDING, OR | | SECTION R322 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, | | AS APPLICABLE. | | | | CITY ORDINANCE NO. 4658-16 | | | | CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16 | | AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT | | AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE | | MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD | | HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM | | BEACH, FL. | | | | ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON | | NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM | | BEACH, BY ORDINANCE, NO. 4658-16, ESTABLISHED A | | TWO-FOOT FREEBOARD ABOVE THE (BFE). | | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION | | PLAN AND/OR FLOOR PLAN. | | | | 1. PROPOSED SITE PLAN SHOWS EXISTING FINISHED FLOOR AT | | 8.82 FT NAVD AND PROPOSED ADDITION WITH FINISHED FLOORS | | AT 8.82 FT NAVD., EXISTING ACCESSORY STRUCTURE FINISHED | | FLOOR IS AT 7.46 FT NAVD AND FREE STANDING GARAGE | | FINISHED FLOOR WILL BE AT 7.46 FT NAVD. | | R322.1.5LOWEST FLOOR. | | | | 2. MACHINERY SERVICING BUILDINGS SHALL BE AT OR ABOVE | | THE DFE OF 8.0 FT NAVD. | | R322.1.6PROTECTION OF MECHANICAL, PLUMBING AND | | ELECTRICAL SYSTEMS. | | | | 3. NEW 2 CAR GARAGE FINISHED FLOOR ELEVATION WILL BE | | 7.46 FT NAVD. | | R322.2.2ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION. | | R322.2.2.1INSTALLATION OF OPENINGS. | | FLOOD OPENINGS REQUIRED. | | | | 4. ACCESSORY STRUCTURE WILL BE CONVERTED TO HABITABLE | | SPACE. FINISHED FLOOR ELEVATION IS 7.46 FT NAVD. | | R322.1.5LOWEST FLOOR. | | R322.2.1ELEVATION REQUIREMENTS. | | R322.2.2ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION. | | R322.2.2.1INSTALLATION OF OPENINGS. | | FLOOD OPENINGS REQUIRED. | | | | NOTICE: PROVIDE AN ELEVATION CERTIFICATE WITH AN | | ACCURATELY COMPLETED BOUNDY LINE SURVEY FOR MAIN | | RESIDENCE AND FREE STANDING GARAGE. | | | | 3 EC S REQUIRED FOR EACH STRUCTURE | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | BUILDING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2021-04-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-26 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-26 |
Time |
14:49 |
Sent To |
|
|
Notes |
2021-04-26 15:42:49 | PLAN REVIEW / NFIP | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | CITY ORDINANCE NO. 4658-16 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: | | | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA). IT IS LOCATED IN ZONE AE WITH A BASE FLOOD | | ELEVATION OF 6.0 FEET NAVD. BASED ON THE VALUE OF THIS | | SUBMITTAL, THE WORK ON THE PROPERTY IS CONSIDERED A | | SUBSTANTIAL IMPROVEMENT (S/I) PER FEMA P-758. | | | | 2020 FBC EXISTING BUILDING | | 1201.3FLOOD HAZARD AREAS. | | IN FLOOD HAZARD AREAS, IF ALL PROPOSED WORK, INCLUDING | | REPAIRS, WORK REQUIRED BECAUSE OF A CHANGE OF | | OCCUPANCY, AND ALTERATIONS, CONSTITUTES SUBSTANTIAL | | IMPROVEMENT, THEN THE BUILDING SHALL COMPLY WITH | | SECTION 1612 OF THE FLORIDA BUILDING CODE, BUILDING, OR | | SECTION R322 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, | | AS APPLICABLE. | | | | CITY ORDINANCE NO. 4658-16 | | | | CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16 | | AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT | | AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE | | MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD | | HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM | | BEACH, FL. | | | | ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON | | NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM | | BEACH, BY ORDINANCE, NO. 4658-16, ESTABLISHED A | | TWO-FOOT FREEBOARD ABOVE THE (BFE). | | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION | | PLAN AND/OR FLOOR PLAN. | | | | 1. PROPOSED SITE PLAN SHOWS EXISTING FINISHED FLOOR AT | | 8.82 FT NAVD AND PROPOSED ADDITIONS WITH FINISHED | | FLOORS AT 8.82 FT AND 8.32 FT NAVD., EXISTING ACCESSORY | | STRUCTURE FINISHED FLOOR IS AT 7.46 FT NAVD AND FREE | | STANDING GARAGE FINISHED FLOOR WILL BE AT 7.46 FT NAVD. | | R322.1.5LOWEST FLOOR. | | | | 2. MACHINERY SERVICING BUILDING SHALL BE AT OR ABOVE | | THE DFE OF 8.0 FT NAVD. | | R322.1.6PROTECTION OF MECHANICAL, PLUMBING AND | | ELECTRICAL SYSTEMS. | | | | 3. NEW 2 CAR GARAGE FINISHED FLOOR ELEVATION WILL BE | | 7.46 FT NAVD. | | R322.2.2ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION. | | R322.2.2.1INSTALLATION OF OPENINGS. | | FLOOD OPENINGS REQUIRED. | | | | 4. ACCESSORY STRUCTURE WILL BE CONVERTED TO HABITABLE | | SPACE. FINISHED FLOOR ELEVATION IS 7.46 FT NAVD. | | R322.1.5LOWEST FLOOR. | | R322.2.1ELEVATION REQUIREMENTS. | | | | NOTICE: PROVIDE AN ELEVATION CERTIFICATE WITH AN | | ACCURATELY COMPLETED BOUNDY LINE SURVEY FOR MAIN | | RESIDENCE AND FREE STANDING GARAGE. | | | | 3 EC S REQUIRED | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | BUILDING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-08-21 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-08-21 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-08-18 |
Time |
06:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-04-19 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-04-19 |
Time |
21:15 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-04-19 |
Time |
17:26 |
Sent To |
|
|
Notes |
2021-04-19 21:14:56 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT-21031623 | | 4/19/2021 | | | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE SEVENTH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SEVENTH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE SEVENTH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE SEVENTH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE SEVENTH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SEVENTH | | EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE SEVENTH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SEVENTH | | EDITION 2020 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1- PLEASE INDICATE ON THE PLANS IN ALL AREAS THE MOST | | CURRENT CODE CYCLE. THE CURRENT CODE CYCLE IS FBC 2020 | | 2- ON PLAN PAGE P3 WATER HEATER NOTE: THERMAL EXPANSION | | IS REQUIRED PER FBC 2020 SEC.607.3THERMAL EXPANSION | | CONTROL. | | WHERE A STORAGE WATER HEATER IS SUPPLIED WITH COLD | | WATER THAT PASSES THROUGH A CHECK VALVE, PRESSURE | | REDUCING VALVE OR BACKFLOW PREVENTER, A THERMAL | | EXPANSION CONTROL DEVICE SHALL BE CONNECTED TO THE | | WATER HEATER COLD WATER SUPPLY PIPE AT A POINT THAT IS | | DOWNSTREAM OF ALL CHECK VALVES, PRESSURE REDUCING | | VALVES AND BACKFLOW PREVENTERS. THERMAL EXPANSION | | CONTROL DEVICES SHALL BE SIZED IN ACCORDANCE WITH THE | | MANUFACTURER?S INSTRUCTIONS AND SHALL BE SIZED SUCH | | THAT THE PRESSURE IN THE WATER DISTRIBUTION SYSTEM | | SHALL NOT EXCEED THAT REQUIRED BY SECTION 604.8. | | 3- IT APPEARS AS THOUGH THE HEAT RECIRCULATION PUMP | | WILL BE INSTALLED OUTDOORS? PLEASE INDICATE HOW THE | | RECIRCULATION PUMP WILL BE PROTECTED AGAINST THE | | OUTDOOR ELEMENTS. | | 4- MASTER BATH TUB REQUIRES A CONTROL VALVE BY A WATER | | TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE 1070 | | OR CSA B125.3, EXCEPT WHERE SUCH PROTECTION IS | | OTHERWISE PROVIDED BY A COMBINATION TUB/SHOWER VALVE IN | | ACCORDANCE WITH SECTION P2708.4. FBC R 2713.3 BATHTUB | | AND WHIRLPOOL BATHTUB VALVES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | ATELYO BELISLE | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6695 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-09-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-09-09 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-09-08 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-04-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-27 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-26 |
Time |
17:14 |
Sent To |
|
|
Notes |
2021-04-27 10:24:43 | PLAN REVIEW / ROOFING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. A ROOFING PERMIT IS REQUIRED. | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | COMPONENTS. | | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2021-12-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-12-01 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-30 |
Time |
16:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-11-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-11-09 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-09 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-15 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-13 |
Time |
13:41 |
Sent To |
|
|
Notes |
2021-10-15 16:28:15 | SIGNATURE REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2017 | | | | 3RD REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: STRUCTURAL ENGINEER OF RECORD, ALI YEMENICILIER, | | P.E. HAS SELF CERTIFIED HIS SIGNATURE. THIS ENGINEER | | HAS BEEN ADVISED IN THE PAST ON 9/29/2020 AND 1/8/2021. | | FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGNATURES AND SEALS PER FS 668.003. | | | | THE DESIGNER OF THE STRUCTURAL SHEETS CANNOT SELF | | CERTIFY THEIR DIGITAL SIGNATURE. THE SIGNATURE MUST BE | | THIRD PARTY VERIFIED. | | 61G15-23.004 F.A.C. | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL | | HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE | | IS: (A) UNIQUE TO THE PERSON USING IT; (B) CAPABLE OF | | VERIFICATION; AS OF NOVEMBER 16, 2020 63 (C) UNDER THE | | SOLE CONTROL OF THE PERSON USING IT; AND, (D) LINKED TO | | A DOCUMENT IN SUCH A MANNER THAT THE DIGITAL SIGNATURE | | AND CORRESPONDINGLY THE DOCUMENT IS INVALIDATED IF ANY | | DATA IN THE DOCUMENT IS CHANGED. | | | | | | EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR DROP | | OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL WET | | SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-09-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-09-09 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-09-09 |
Time |
05:36 |
Sent To |
|
|
Notes |
2021-09-09 09:46:17 | SIGNATURE REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2017 | | | | 2ND REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: STRUCTURAL ENGINEER OF RECORD, ALI YEMENICILIER, | | P.E. HAS SELF CERTIFIED HIS PLANS. THIS ENGINEER HAS | | BEEN ADVISED IN THE PAST ON 9/29/2020 AND 1/8/2021. | | FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGNATURES AND SEALS PER FS 668.003. | | | | THE DESIGNER OF THE STRUCTURAL SHEETS CANNOT SELF | | CERTIFY THEIR DIGITAL SIGNATURE. THE SIGNATURE MUST BE | | THIRD PARTY VERIFIED. | | 61G15-23.004 F.A.C. | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL | | HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE | | IS: (A) UNIQUE TO THE PERSON USING IT; (B) CAPABLE OF | | VERIFICATION; AS OF NOVEMBER 16, 2020 63 (C) UNDER THE | | SOLE CONTROL OF THE PERSON USING IT; AND, (D) LINKED TO | | A DOCUMENT IN SUCH A MANNER THAT THE DIGITAL SIGNATURE | | AND CORRESPONDINGLY THE DOCUMENT IS INVALIDATED IF ANY | | DATA IN THE DOCUMENT IS CHANGED. | | | | | | EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR DROP | | OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL WET | | SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-04-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-04-12 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-04-12 |
Time |
09:24 |
Sent To |
|
|
Notes |
2021-04-12 09:26:46 | THE DESIGNER OF THE STRUCTURAL SHEETS CANNOT SELF | | CERTIFY THEIR DIGITAL SIGNATURE. THE SIGNATURE MUST BE | | THIRD PARTY VERIFIED. | | | | | | 61G15?23.004 F.A.C. | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL | | HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE | | IS: (A) UNIQUE TO THE PERSON USING IT; (B) CAPABLE OF | | VERIFICATION; AS OF NOVEMBER 16, 2020 63 (C) UNDER THE | | SOLE CONTROL OF THE PERSON USING IT; AND, (D) LINKED TO | | A DOCUMENT IN SUCH A MANNER THAT THE DIGITAL SIGNATURE | | AND CORRESPONDINGLY THE DOCUMENT IS INVALIDATED IF ANY | | DATA IN THE DOCUMENT IS CHANGED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-09-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-09-08 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-09-08 |
Time |
13:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-04-23 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-04-23 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-04-23 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|