Plan Review Details - Permit 21031619
Plan Review Stops For Permit 21031619 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-05-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-03 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-04-30 |
Time |
10:25 |
Sent To |
|
|
Notes |
2021-05-03 07:54:52 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) ON SHEET A3, THERE IS A WALL ID TAG (6) ON THE FLOOR | | PLAN, HOWEVER, THERE IS NO WALL TYPE (6) LISTED IN THE | | LEGEND. PLEASE CLARIFY. FBC AMENDMENTS 107.2.1 | | 2) ON SHEET A5 THE GUARDRAIL IS SPECIFIED AS 42" HIGH | | ON THE PLAN AND 36" IN THE DETAIL. PLEASE CLARIFY. FBC | | AMENDMENTS 107.2.1 | | 3) SUBMIT THE PRODUCT APPROVAL FOR THE AH160 ROOF TILE | | ADHESIVE. FAC RULE 61G20 | | 4) SUBMIT PRODUCT APPROVALS THAT HAVE BEEN VALIDATED OR | | CERTIFIED AS COMPLYING WITH THE 2020 FBC SEVENTH | | EDITION. THE PRODUCT APPROVAL FOR THE UNCLIPPED | | MULLIONS IS THE ONLY ONE THAT IS CERTIFIED TO COPY WITH | | THE 2020 FBC. FBC AMENDMENTS 107.2.1 & FAC RULE 61G20 | | 5) HI-LIGHT OR CIRCLE THE SPECIFIC ITEMS, SIZES, DESIGN | | PRESSURES, DETAILS, ETC. IN THE PRODUCT APPROVALS THAT | | WILL BE INSTALLED. FBC AMENDMENTS 107.2.1 | | 6) THE DESIGNER OF RECORD IS REQUIRED TO REVIEW AND | | APPROVE THE PRODUCT APPROVALS IN WRITING. FBC | | AMENDMENTS 107.3.4 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-04-22 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-04-22 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-04-22 |
Time |
08:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2021-04-27 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2021-04-27 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2021-04-21 |
Time |
16:21 |
Sent To |
|
|
Notes |
2021-04-27 09:07:29 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | 1. THE PERMIT VALUE EXCEEDS 50% OF THE IMPROVEMENT | | VALUE OF THE PROPERTY. THE PROPERTY IS REQUIRED TO | | COMPLY WITH CURRENT LANDSCAPING PERMITS PER SECTION | | 94-442(C)(2) A. SINGLE FAMILY DWELLING UNITS. PLEASE | | SPEAK WITH RAY CARANCI, SENIOR LANDSCAPING PLANNER - | | [email protected] OR ANDREW BURNETT, LANDSCAPE PLANNER | | - [email protected] TO SHOW COMPLIANCE WITH CURRENT | | LANDSCAPING REQUIREMENTS OR SUBMIT A LANDSCAPING | | PERMIT. ZONING REVIEW WILL NOT PASS UNTIL A LANDSCAPING | | PERMIT NUMBER HAS BEEN ASSIGNED AND PAID FOR OR THE | | LANDSCAPE PLANNERS GIVE THE OKAY THAT IT COMPLIES. | | 2. REVISE W9 TO HAVE OPTIONAL TEXTURED GLASS SUCH AS | | RAIN DROP TEXTURED GLASS. FROSTED GLASS IS NOT AN | | OPTION. | | 3. ALL CGI WINDOWS AND DOORS SHALL USE AN EXTERNAL | | DIMENSIONAL MUNTIN PROFILE. FOR CGI PRODUCTS THIS IS | | THE SEMI-CONTOURED PROFILE. | | 4. INDICATE COLOR OF S-TILE. TILE SHALL HAVE AN EARTH | | TONE COLOR. | | 5. PROVIDE A MUNTIN DETAIL FOR THE FRONT DOOR AND FIXED | | WINDOW. THIS NEEDS TO MATCH THE CGI MUNTIN PROFILE. | | 6. SEPARATE PERMIT REQUIRED FOR FENCE/WALL, AWNINGS, | | GENERATOR, MECHANICAL/AC/POOL EQUIPMENT, IRRIGATION, | | LANDSCAPING. PLEASE ACKNOWLEDGE THIS. | | | | | | PROPOSED CONDITIONS, SUBJECT TO CHANGE. CONFIRM THAT | | THE PROPOSED PRODUCT(S) WILL COMPLY WITH THESE | | CONDITIONS. | | 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE | | ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND | | MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL | | WINDOWS UNLESS AS OTHERWISE INDICATED BY A MODIFICATION | | OF THE WINDOW FRAME. WINDOW CASING SHALL NOT EXCEED | | BEYOND THE EXTERIOR WOOD FRAMING. | | 2. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR. | | ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR | | WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS | | MAY BE USED ON NON-STREET FACING BATHROOMS ONLY. | | | | AARON BORNGRABER, AICP | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | PLANNING DIVISION | | [email protected] | OFFICE: 561.822.1428 | TTY: | | 800.955.8771 | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | FL 33402 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-05-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-03 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-04-14 |
Time |
15:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-04-20 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-04-20 |
Time |
15:10 |
Sent To |
|
|
Notes |
2021-04-20 15:24:49 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-21031619 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) A MECHANICAL SUB-PERMIT IS REQUIRED. | | | | 2) FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN | | MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE | | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE | | SPECIFIC PROJECT WHICH HE OR SHE INSTALLS. | | PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A | | SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING | | CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING, | | OR | | THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL | | PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE | | COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER | | PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO | | THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1. | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | THERE IS NO MECHANICAL SUB PERMIT FOR THIS JOB. | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-04-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-22 |
Time |
13:21 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-22 |
Time |
11:39 |
Sent To |
|
|
Notes |
2021-04-22 13:21:30 | 1ST REVIEW FBC-2020 RES. | | PERMIT- 21031619 | | 4/21/2021 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET A7: PROVIDE A SHOWER PAN DETAIL- SECTIONS | | P2709.1 & P2709.2 FBC RES. | | | | 2) A7: PROVIDE A CLEANOUT AT THE JUNCTION OF THE | | BUILDING DRAIN AND SEWER- P3005.2.3 FBC RES. | | | | 3) A7: SHOW THE LOCATION OF THE SHUTOFF VALVES FOR THE | | WASHING MACHINE. THE VALVES SHALL BE IN A LOCATION THAT | | CAN BE ACCESSED- SEE SECTION P2903.9.3 FBC RES. AND | | DEFINITION OF ACCESS- SECTION 202 FBC P. THE VALVES | | CANNOT BE LOCATED BEHIND THE STACKABLE WASHER/DRYER | | UNIT. | | | | 4) A7: THE WATER RISER SHOWS A POTABLE WATER BACKFLOW | | PREVENTER. PLEASE PLACE A NOTE TO INDICATE A SEPARATE | | PERMIT IS REQUIRED- SECTION 105.1 WPB. A FL. LICENSED | | PLUMBING CONTRACTOR SHALL OBTAIN A SEPARATE PERMIT FOR | | INSTALLATION OF THE BACKFLOW PREVENTER IN ACCORDANCE | | WITH SECTION 105.1 WPB AND SEC. 90-33 WPB CODE OF | | ORDINANCES. THE DEVICE SHALL BE TESTED AND CERTIFIED BY | | THE WPB UTILITIES DEPARTMENT PRIOR TO FINAL INSPECTION | | BY THE BUILDING DEPARTMENT. PLEASE CONTACT THE WPB | | UTILITIES CENTRAL OPERATIONS DEPT. AT 561-822-2210 FOR | | FURTHER INFORMATION. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-05-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-03 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-03 |
Time |
08:53 |
Sent To |
|
|
Notes |
2021-05-03 08:57:18 | CONCERETE ROOF TILE - NOA NO. 19-0715.02 | | UNDERLAYMENT- NOA NO. 20-0723.36 | | NO PRODUCT APPROVAL SUBMITTED FOR ROOF TILE ADHESIVE |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-05-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-03 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-03 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-04-27 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2021-04-27 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2021-04-27 |
Time |
09:06 |
Sent To |
|
|
Notes |
2021-04-27 09:07:14 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | 1. THE PERMIT VALUE EXCEEDS 50% OF THE IMPROVEMENT | | VALUE OF THE PROPERTY. THE PROPERTY IS REQUIRED TO | | COMPLY WITH CURRENT LANDSCAPING PERMITS PER SECTION | | 94-442(C)(2) A. SINGLE FAMILY DWELLING UNITS. PLEASE | | SPEAK WITH RAY CARANCI, SENIOR LANDSCAPING PLANNER - | | [email protected] OR ANDREW BURNETT, LANDSCAPE PLANNER | | - [email protected] TO SHOW COMPLIANCE WITH CURRENT | | LANDSCAPING REQUIREMENTS OR SUBMIT A LANDSCAPING | | PERMIT. ZONING REVIEW WILL NOT PASS UNTIL A LANDSCAPING | | PERMIT NUMBER HAS BEEN ASSIGNED AND PAID FOR OR THE | | LANDSCAPE PLANNERS GIVE THE OKAY THAT IT COMPLIES. | | 2. REVISE W9 TO HAVE OPTIONAL TEXTURED GLASS SUCH AS | | RAIN DROP TEXTURED GLASS. FROSTED GLASS IS NOT AN | | OPTION. | | 3. ALL CGI WINDOWS AND DOORS SHALL USE AN EXTERNAL | | DIMENSIONAL MUNTIN PROFILE. FOR CGI PRODUCTS THIS IS | | THE SEMI-CONTOURED PROFILE. | | 4. INDICATE COLOR OF S-TILE. TILE SHALL HAVE AN EARTH | | TONE COLOR. | | 5. PROVIDE A MUNTIN DETAIL FOR THE FRONT DOOR AND FIXED | | WINDOW. THIS NEEDS TO MATCH THE CGI MUNTIN PROFILE. | | 6. SEPARATE PERMIT REQUIRED FOR FENCE/WALL, AWNINGS, | | GENERATOR, MECHANICAL/AC/POOL EQUIPMENT, IRRIGATION, | | LANDSCAPING. PLEASE ACKNOWLEDGE THIS. | | | | | | PROPOSED CONDITIONS, SUBJECT TO CHANGE. CONFIRM THAT | | THE PROPOSED PRODUCT(S) WILL COMPLY WITH THESE | | CONDITIONS. | | 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE | | ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND | | MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL | | WINDOWS UNLESS AS OTHERWISE INDICATED BY A MODIFICATION | | OF THE WINDOW FRAME. WINDOW CASING SHALL NOT EXCEED | | BEYOND THE EXTERIOR WOOD FRAMING. | | 2. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR. | | ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR | | WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS | | MAY BE USED ON NON-STREET FACING BATHROOMS ONLY. | | | | AARON BORNGRABER, AICP | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | PLANNING DIVISION | | [email protected] | OFFICE: 561.822.1428 | TTY: | | 800.955.8771 | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | FL 33402 | | | | |
|
|
|