Plan Review Details - Permit 21031557
Plan Review Stops For Permit 21031557 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-01 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-01 |
Time |
12:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-05-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-07 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-07 |
Time |
10:51 |
Sent To |
|
|
Notes |
2021-05-07 11:55:52 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT GENERATOR PAD DRAWINGS WITH GENERATOR TO PAD | | ANCHORING DETAILS. IF A PREFABRICATED GENERATOR PAD | | WILL BE USED SUBMIT SITE SPECIFIC GENERATOR PAD | | ENGINEERING THAT HAS BEEN SIGNED AND SEALED BY THE | | ENGINEER. FBC 107.2.1 | | | | 2) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | FEET FROM ANY OPENINGS INTO A BUILDING. FBC-R303.5.1 | | INTAKE OPENINGS. MECHANICAL AND GRAVITY OUTDOOR AIR | | INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET | | (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT, | | SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, STREETS, | | ALLEYS, PARKING LOTS AND LOADING DOCKS. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-05-07 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-05-07 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-05-07 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2021-05-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-05-07 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-05-07 |
Time |
08:01 |
Sent To |
|
|
Notes |
2021-05-07 09:01:12 | THE PERMIT APPLICATION INDICATES THE GAS FOR THE | | GENERATOR WILL BE UNDER A SEPARATE PERMIT- NO GAS PLANS | | WERE SUBMITTED. | | CCOLE- 5/7/21 | 2021-05-07 08:19:32 | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-01 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-06-21 |
Time |
06:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-06-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-16 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-16 |
Time |
15:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2021-05-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-05-07 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-05-07 |
Time |
08:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-01 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-01 |
Time |
12:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-05-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-07 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-07 |
Time |
10:51 |
Sent To |
|
|
Notes |
2021-05-07 11:48:04 | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM. | | YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 & | | 61G15 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-06-15 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-06-15 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-06-15 |
Time |
10:04 |
Sent To |
I |
|
Notes |
|
|
|