Plan Review Details - Permit 21031323
Plan Review Stops For Permit 21031323
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-04-21 Cont ID  
Sent By rmcdouga Date 2021-04-21 Time 07:52 Rev Time 0.00
Received By rmcdouga Date 2021-04-21 Time 07:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-04-13 Cont ID  
Sent By rmcdouga Date 2021-04-13 Time 15:10 Rev Time 0.00
Received By rmcdouga Date 2021-04-13 Time 15:10 Sent To  
Notes
2021-04-13 15:10:44PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) RESOLVED.
  
 2) NOT RESOLVED. [THE SIGNED AND SEALED WIND LOAD CHART
 THAT WAS SUBMITTED IS FOR EXPOSURE CATEGORY C AND THIS
 BUILDING IS LOCATED IN EXPOSURE CATEGORY D. SUBMIT A
 WIND LOAD CHART FOR BUILDINGS TALLER THAN 60 FEET IN
 EXPOSURE CATEGORY D. SPECIFY THE BUILDING HEIGHT AND
 THE WALL ZONE FOR EACH OF THE WINDOWS.] THE WINDOWS ARE
 LOCATED IN A HIGH RISE BUILDING THAT IS MORE THAN 60
 FEET IN HEIGHT WITH A 170 MPH WIND SPEED IN EXPOSURE
 CATEGORY D. SUBMIT SIGNED AND SEALED COMPONENT AND
 CLADDING WIND LOAD PRESSURES FROM A FLORIDA LICENSED
 ENGINEER FOR EACH OF THE WINDOW OPENINGS. FBC 1609
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-04-09 Cont ID  
Sent By rmcdouga Date 2021-04-09 Time 08:25 Rev Time 0.00
Received By rmcdouga Date 2021-04-09 Time 08:16 Sent To  
Notes
2021-04-09 08:44:09PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) REVISE NOTE (4) ON SHEET A1 TO SPECIFY THE 2020 FBC
 SEVENTH EDITION. THE PLAN REFERENCES THE FBC SIXTH
 EDITION (2017). THE FBC SEVENTH EDITION (2020) WENT
 INTO EFFECT ON DECEMBER 31, 2020. ALL NEW PERMITS
 APPLIED FOR ON OR AFTER THAT DATE ARE REQUIRED TO
 COMPLY WITH AND REFERENCE THE 2020 FBC SEVENTH EDITION.
 FS CHAPTER 553
  
 2) THE WINDOWS ARE LOCATED IN A HIGH RISE BUILDING THAT
 IS MORE THAN 60 FEET IN HEIGHT WITH A 170 MPH WIND
 SPEED IN EXPOSURE CATEGORY D. SUBMIT SIGNED AND SEALED
 COMPONENT AND CLADDING WIND LOAD PRESSURES FROM A
 FLORIDA LICENSED ENGINEER FOR EACH OF THE WINDOW
 OPENINGS. FBC 1609
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-04-21 Cont ID  
Sent By rmcdouga Date 2021-04-21 Time 07:52 Rev Time 0.00
Received By rmcdouga Date 2021-04-15 Time 08:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-13 Cont ID  
Sent By rmcdouga Date 2021-04-13 Time 15:11 Rev Time 0.00
Received By rmcdouga Date 2021-04-12 Time 10:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-04-09 Cont ID  
Sent By rmcdouga Date 2021-04-09 Time 08:25 Rev Time 0.00
Received By rmcdouga Date 2021-03-25 Time 16:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-04-21 Cont ID  
Sent By rmcdouga Date 2021-04-21 Time 07:52 Rev Time 0.00
Received By rmcdouga Date 2021-04-21 Time 07:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-04-13 Cont ID  
Sent By rmcdouga Date 2021-04-13 Time 15:11 Rev Time 0.00
Received By rmcdouga Date 2021-04-13 Time 15:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-04-09 Cont ID  
Sent By rmcdouga Date 2021-04-09 Time 08:25 Rev Time 0.00
Received By rmcdouga Date 2021-04-09 Time 08:16 Sent To  
Notes
2021-04-09 08:45:31SIGNATURE WILL BE EVALUATED WHEN SIGNED AND SEALED WIND
 LOADS ARE SUBMITTED.


Account Summary | Usage Policy | Privacy Policy