Plan Review Stops For Permit 21031268 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-08-11 |
Time |
15:00 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-10-21 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-10-21 |
Time |
11:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-08-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-13 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-13 |
Time |
09:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2021-08-04 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-08-04 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-08-04 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-12-21 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-12-06 |
Time |
12:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-11-30 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-11-15 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-10-22 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-10-22 |
Time |
11:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-08-17 |
Time |
|
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2021-07-30 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-10-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-10-01 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-10-01 |
Time |
13:26 |
Sent To |
|
|
Notes |
2021-10-01 13:29:43 | APPROVED WITH PRIVISO: | | THE CONDENSING UNIT MUST BE PROTECTED FROM PHYSICAL | | DAMAGE. FBC M 303.4 | | THE CONDENSATION DRAINAGE MUST MEET FBC M 307 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-08-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-16 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-16 |
Time |
16:04 |
Sent To |
|
|
Notes |
2021-08-16 16:10:07 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-21031268 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS. FBC EC C402 | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. FBC EC C403.2.1 | | | | 3) PLEASE SHOW VENTILATION FOR THIS PROPERTY, IS IT | | GOING TO BE NATURAL (FBC M 402) OR MECHANICAL (FBC M | | 403)? | | | | 4) PLEASE SHOW THE RETURN AIR PATH FROM THE SITTING | | AREA BACK TO THE AHU. FBC 601.6 | | | | 5) PLEASE SHOW THE LOCATION WHERE THE CONDENSING UNIT | | WILL BE LOCATED. FBC 107.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2021-11-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-11-19 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-11-19 |
Time |
16:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-10-13 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-10-13 |
Time |
12:23 |
Sent To |
|
|
Notes |
2021-10-13 12:23:54 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIT- 21031268 | | 10/13/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. COMMENT #1 FROM THE 1ST | | REVIEW LISTED BELOW HAS NOT BEEN COMPLETELY ADDRESSED. | | A) PLEASE SHOW THE HIGH FOUNTAIN IN THE DETAIL ON SHEET | | 2.0 INCLUDING THE SPOUT HEIGHT. B) COMPLIANCE WITH | | PROTRUSION LIMITS NOT PROVIDED. WILL A BARRIER-FREE | | TYPE DRINKING FOUNTAIN BE INSTALLED? PLEASE PROVIDE AN | | EQUIPMENT SCHEDULE AND SPEC SHEET TO VERIFY COMPLIANCE. | | | | 1) PROVIDE A PLUMBING PLAN SHOWING THE SCOPE OF WORK | | FOR DEMOLITION AND ALTERATIONS. SHEET 2.0 APPEARS TO | | SHOW A SINK IS BEING REMOVED AND A WATER COOLER IS | | BEING INSTALLED. PLEASE REFER TO SECTIONS 211.1 & 211.2 | | FBC ACC- WHERE DRINKING FOUNTAINS ARE PROVIDED NO FEWER | | THAN TWO SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL | | BE A LO AND THE OTHER A HI. PLEASE SEE SECTIONS 602.1- | | 602.6, 602.7, 306 & 307 AND PROVIDE INSTALLATION | | DETAILS INCLUDING ELEVATION VIEWS SHOWING KNEE AND TOE | | CLEARANCES, SPOUT HEIGHTS, AND SPOUT LOCATIONS. SHOW | | THE REQUIRED 30 X 48 IN. CLEAR FLOOR SPACE FOR A | | FORWARD WHEELCHAIR APPROACH TO THE FOUNTAIN- SECTION | | 602.2 FBC ACC, AND SHOW HOW THE LOCATIONS OF THE | | FOUNTAINS WILL BE IN COMPLIANCE WITH SECTION 307.2 | | PROTRUSION LIMITS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-08-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-08-17 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-08-17 |
Time |
10:07 |
Sent To |
|
|
Notes |
2021-08-17 10:53:23 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 21031268 | | 8/17/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE A PLUMBING PLAN SHOWING THE SCOPE OF WORK | | FOR DEMOLITION AND ALTERATIONS. SHEET 2.0 APPEARS TO | | SHOW A SINK IS BEING REMOVED AND A WATER COOLER IS | | BEING INSTALLED. PLEASE REFER TO SECTIONS 211.1 & 211.2 | | FBC ACC- WHERE DRINKING FOUNTAINS ARE PROVIDED NO FEWER | | THAN TWO SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL | | BE A LO AND THE OTHER A HI. PLEASE SEE SECTIONS 602.1- | | 602.6, 602.7, 306 & 307 AND PROVIDE INSTALLATION | | DETAILS INCLUDING ELEVATION VIEWS SHOWING KNEE AND TOE | | CLEARANCES, SPOUT HEIGHTS, AND SPOUT LOCATIONS. SHOW | | THE REQUIRED 30 X 48 IN. CLEAR FLOOR SPACE FOR A | | FORWARD WHEELCHAIR APPROACH TO THE FOUNTAIN- SECTION | | 602.2 FBC ACC, AND SHOW HOW THE LOCATIONS OF THE | | FOUNTAINS WILL BE IN COMPLIANCE WITH SECTION 307.2 | | PROTRUSION LIMITS. | | | | 2) PROVIDE SANITARY DRAINAGE AND WATER RISER DRAWINGS | | FOR REQUIRED DRINKING FOUNTAIN PLUMBING PIPING | | INSTALLATIONS- SECTION 107.3.5.1.3 WPB. | | | | 3) PROVIDE A SLAB REPAIR DETAIL FOR INSTALLATION OF | | UNDERSLAB DRAIN PIPING- SECTION 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-12-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-12-21 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-12-21 |
Time |
12:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2021-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-11-30 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-11-30 |
Time |
10:07 |
Sent To |
|
|
Notes |
2021-11-30 10:07:14 | THE PLAN SHEET LABELED 4.0 WITH THE ELECTRIC/MECHANICAL | | PLANS IS NOT DIGITALLY SIGNED AND SEALED BY THE | | DESIGNER. THERE IS AN ARCHITECT'S TITLE BLOCK ON THE | | PAGE. ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO | | HAVE THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON | | THEM. YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 & | | 61G15 | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-10-22 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-10-22 |
Time |
11:50 |
Sent To |
|
|
Notes |
2021-10-22 11:55:44 | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND | | SIGNED. | | IT APPEARS THAT PLAN LABELED ?2.0 AND 4.0? ARE NOT | | DIGITALLY SEALED AND SIGNED PLANS. PLEASE CORRECT THESE | | ISSUES BY PROPERLY SIGNING AND SEALING THEM AS | | DESCRIBED BELOW. | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION. | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | DOCUMENTS ARE PREFERRED. | | | | PLEASE EMAIL [email protected] AND CC TO | | [email protected] | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-08-11 |
Time |
15:01 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2021-11-29 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2021-11-29 |
Time |
11:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-10-08 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2021-10-08 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2021-10-08 |
Time |
|
Sent To |
|
|
Notes |
2021-10-08 16:37:39 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) PER APPLICANT?S RESPONSE TO STAFF'S 8/11 COMMENT ON | | THE USE, A CARWASH USE REQUIRES A CLASS B SPECIAL USE | | PERMIT TO OPERATE. A CLASS B SPECIAL USE PERMIT | | REQUIRES APPROVAL FROM THE ZONING BOARD OF APPEALS | | (ZBA). ZBA APPROVAL IS REQUIRED PRIOR TO ZONING | | APPROVAL OF THIS PERMIT. | | | | | | NOTES: | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: BMUD- TYPE II | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2021-08-11 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2021-08-11 |
Time |
|
Sent To |
|
|
Notes |
2021-08-11 14:52:11 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) UPDATED SIGNED AND SEALED SURVEY IS REQUIRED. | | | | 2.) WHAT IS THE PROPOSED USE OF THE BUILDING? | | | | | | | | NOTES: | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: BMUD-TYPE II |
|
|