Plan Review Details - Permit 21031243
Plan Review Stops For Permit 21031243
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-04-08 Cont ID  
Sent By cpuell Date 2021-04-08 Time 09:22 Rev Time 0.00
Received By cpuell Date 2021-04-08 Time 09:22 Sent To  
Notes
2021-04-08 09:24:30CURRENTLY REAR BUILDING HAS A HALF ADDRESS WHICH IS NO
 LONGER ALLOWED, I ASSUME THAT THE GUEST HOUSE IS BEING
 INCORPORATED INTO THE BACK BUILDING. IF THE GUEST HOUSE
 IS TAKING THE PLACE OF THE CURRENT REAR BUILDING A NEW
 ADDRESS WILL NEED TO BE ASSIGNED TO THE GUEST HOUSE AS
 HALF ADDRESSES ARE NO LONGER ALLOWED. PLEASE CONTACT
 [email protected] TO DISCUSS ADDRESS OPTIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-03 Cont ID  
Sent By cthroop Date 2021-05-03 Time 11:35 Rev Time 0.00
Received By cthroop Date 2021-05-03 Time 07:34 Sent To  
Notes
2021-05-03 11:45:36PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 1&2 FAMILY - SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A SITE DRAINAGE PLAN.
 FBC R401.3 SITE DRAINAGE
 PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH
 FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 2. PROVIDE AN ENERGY SUBMITTAL.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 3. PROVIDE FL PRODUCT APPROVALS FOR WINOWS AND DOORS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 4. PROVIDE THE ICC-ES REPORT OR A FL PRODUCT APPROVAL
 FOR THE SPRAY APPLIED INSULATION.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 5. PROVIDE A ROOF SHEATHING FASTENER SCHEDULE PER THE
 ROOF ZONE PRESSURE CALCULATIONS ON PLAN PAGE S-3.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING
 SCHEDULE FOR WOOD STRUCTURAL PANELS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-04-22 Cont ID  
Sent By equinone Date 2021-04-22 Time 14:34 Rev Time 0.00
Received By equinone Date 2021-04-22 Time 14:34 Sent To  
Notes
2021-04-22 15:05:05CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW:
  
 1) SHEET E101 ELECTRICAL PLAN: ELECTRICAL NOTE NO. 6.
 REFERENCES TO CODES ARE OUTDATED. PLEASE SEE BELOW FOR
 CURRENT CODES AND UPDATE NOTE TO REFLECT THEM.
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
  
 2) SHEET E101 ELECTRICAL PLAN: ELECTRICAL NOTE NO. 28.
 CURRENT FLORIDA ENERGY CODE 2020 7TH EDITION REQUIRES
 THAT:
  
 "R 404.1 NOT LESS THAN 90 PERCENT OF THE LAMPS IN
 PERMANENTLY INSTALLED LUMINAIRES SHALL HAVE AN EFFICACY
 OF AT LEAST 45 LUMENS-PER-WATT OR SHALL UTILIZE LAMPS
 WITH AN EFFICACY OF NOT LESS THAN 65 LUMENS-PER-WATT."
  
 PLEASE UPDATE NOTE TO REFLECT NEW CODE REQUIREMENTS
  
 3) PLEASE PROVIDE UPDATED PANEL SCHEDULE FOR EXISTING
 PANEL AND NEW PANEL. INCLUDE AIC RATINGS, MCB SIZES.
  
 4) SHEET A400 (SCHEDULES - RISERS): LOAD CALCULATION
 FOR NEW PANEL INDICATES A TOTAL DEMAND LOAD OF 72.8
 AMPS
 BUT RISER DIAGRAM SPECIFIES A #6 CU FEEDER FROM
 EXISTING PANEL WHICH ONLY HAS AN AMPACITY OF 65 AMPS.
 PLEASE PROVIDE CORRECTION. THE CALCULATIONS ARE LABELED
 "NEW SERVICE LOAD CALCULATION" BUT THIS IS NOT A NEW
 SERVICE BUT LOAD CALCUTIONS FOR GUEST HOUSE PANEL.
 PLEASE LABEL PROPERLY.
  
 5) NEW PANEL FOR GUEST HOUSE MUST BE GROUNDED AS PER
 NEC 250.32. PLEASE INCLUDE GROUNDING DETAILS FOR GUEST
 PANEL ON RISER DIAGRAM.
  
  
 ENRIQUE QUINONEZ P.E.
 ELECTRICAL PLANS EXAMINER
 DEVELOPMENT SERVICES
 CITY OF WEST PAM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6746.
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-04-22 Cont ID  
Sent By ccole Date 2021-04-22 Time 16:38 Rev Time 0.00
Received By ccole Date 2021-04-22 Time 16:07 Sent To  
Notes
2021-04-22 16:38:401ST REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 21031243
 4/22/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE GAS PLANS INCLUDING A GAS PIPING RISER,
 COMBUSTION AIR CALCULATIONS AND VENTING PLANS- SECTIONS
 107.2.1, 107.3.5.3 WPB AND FBC RES. FUEL GAS.
  
 2) GAS RISER SHALL INCLUDE:
 A) TYPE OF GAS- NATURAL OR LP.
 B) LOCATION OF METER OR LP TANK(S) AND1ST STAGE
 DELIVERY PRESSURE.
 C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 D) TYPES AND SIZES OF PIPING.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 G) LOCATIONS OF 2ND STAGE REGULATORS, SHUTOFF VALVES,
 AND PIPE UNIONS.
 H) INLET AND OUTLET PRESSURES AT REGULATORS.
 I) LOCATIONS AND TYPES OF PIPE SLEEVES.
 K) PIPE SIZING TABLES OR PIPE SIZING METHOD USED.
  
 3) PROVIDE COMBUSTION AIR CALCULATIONS AND INDICATE HOW
 THE AIR WILL BE PROVIDED TO THE GAS RANGE- SECTION-
 G2407.1 FBC RES.
  
 4) PROVIDE MAKEUP AIR FOR THE DRYER AND INDICATE HOW
 THE MAKEUP AIR WILL BE PROVIDED- G2439.5 FBC RES.
  
 5) PROVIDE EQUIPMENT SCHEDULES FOR THE TANKLESS WATER
 HEATERS INDICATING MAKES AND MODELS, BTU CAPACITIES,
 AND EFFICIENCY RATING PER TABLE C404.1 FBC EC.
  
 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL GAS
 FIRED APPLIANCES- SECTION G2408.1 FBC RES.
  
 7) SUBMIT A GAS SUB-PERMIT IF THE INSTALLATIONS ARE TO
 BE INCLUDED UNDER THE MASTER PERMIT- SECTION 105.1 WPB.
 IF THE GAS INSTALLATIONS ARE TO BE UNDER A SEPARATE
 PRIMARY PERMIT, PLEASE PLACE A NOTE ON THE PLAN.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-14 Cont ID  
Sent By lmarchan Date 2021-05-14 Time 07:38 Rev Time 0.00
Received By lmarchan Date 2021-04-08 Time 08:39 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-05-03 Cont ID  
Sent By cthroop Date 2021-05-03 Time 11:33 Rev Time 0.00
Received By cthroop Date 2021-05-03 Time 11:33 Sent To  
Notes
2021-05-03 11:33:47PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-04-21 Cont ID  
Sent By medwards Date 2021-04-21 Time 12:40 Rev Time 0.00
Received By medwards Date 2021-04-21 Time 12:34 Sent To  
Notes
2021-04-21 12:45:54CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1) A MECHANICAL SUB-PERMIT IS REQUIRED.
  
 2) FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN
 MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE
 MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE
 SPECIFIC PROJECT WHICH HE OR SHE INSTALLS.
 PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A
 SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING
 CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING,
 OR
 THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL
 PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE
 COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER
 PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO
 THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN.
  
  
 THERE IS NO MECHANICAL SUB PERMIT FOR THIS JOB.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-04-22 Cont ID  
Sent By ccole Date 2021-04-22 Time 16:04 Rev Time 0.00
Received By ccole Date 2021-04-22 Time 14:22 Sent To  
Notes
2021-04-22 16:04:501ST REVIEW FBC-2020 RES.
 PERMIT- 21031243
 4/22/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A100, A101, & A400: THE SANITARY RISER
 DRAWING DOES NOT INCLUDE THE ALTERED SANITARY PIPING IN
 THE KITCHEN, MASTER BATH, AND THE 2ND FLOOR BATH-
 SECTION 107.3.5.3 WPB.
  
 2) A400: CORRECT THE RISER TO SHOW A 2 IN. STANDPIPE
 FOR THE WASHING MACHINE CONNECTING TO A 3 IN. STACK-
 SECTION 406.2 FBC P.
  
 3) A101: PROVIDE THE DIMENSIONS OF THE SHOWERS IN THE
 GUEST BATH AND 2ND FLOOR BATH- SECTION P2708.1 FBC RES.
  
 4) PROVIDE SHOWER PAN DETAILS FOR THE MASTER BATH,
 GUEST BATH, AND 2ND FLOOR BATH- SECTION P2709.1 &
 P2709.2 FBC RES.
  
 5) PROVIDE SHOWER AND BATHTUB VALVE COMPLIANCE
 INFORMATION ON THE PLAN- SECTIONS P2708.4 & P2713.3 FBC
 RES.
  
 6) PROVIDE IRRIGATION PLANS OR INDICATE THE PLANS WILL
 BE SUBMITTED UNDER SEPARATE PERMIT- SECTION 105.1 &
 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2021-05-13 Cont ID  
Sent By rgathrig Date 2021-05-13 Time 17:55 Rev Time 0.00
Received By rgathrig Date 2021-05-13 Time 17:55 Sent To  
Notes
2021-05-13 17:56:53PRIVATE PROVIDER REVIEW APPROVED
  
 TEW & TAYLOR PRIVATE PROVIDER INSPECTIONS ONLY
  
 RICHARD GATHRIGHT
 ASSISTANT BUILDING OFFICIAL

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2021-05-03 Cont ID  
Sent By cthroop Date 2021-05-03 Time 11:33 Rev Time 0.00
Received By cthroop Date 2021-05-03 Time 07:34 Sent To  
Notes
2021-05-03 11:34:34PROVISO ON PLAN PAGE S-3. SEPERATE ROOFING PERMIT IS
 REQUIRED. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-04-21 Cont ID  
Sent By medwards Date 2021-04-21 Time 12:53 Rev Time 0.00
Received By medwards Date 2021-04-21 Time 12:53 Sent To  
Notes
2021-04-21 12:55:45THE STRUCTURE SHEET'S DIGITAL SIGNATURE'S WILL NOT
 READ. IT APPEARS THAT THEY ARE A COPY OF THE ORIGINAL
 DIGITAL SIGNATURES. PLEASE UPLOAD THE ORIGINAL SIGNED
 AND SEALED DIGITAL SIGNATURES. FS 471.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2021-05-11 Cont ID  
Sent By rthermid Date 2021-05-11 Time   Rev Time  
Received By rthermid Date 2021-05-11 Time   Sent To I
Notes
2021-05-11 09:26:54ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 5/11/2021
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. UNDER A SEPERATE DRIVEWAY PERMIT, 75% OR 1000 SF OF
 THE FRONT YARD AREA HAS TO BE LANDSCAPE.
 2. SUBMIT AN APPLICATION FOR A SEPERATE LANDSCAPE
 PERMIT.
 3. ADDRESS STRUCTURAL COMMENTS.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN
 INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
  
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved