Plan Review Stops For Permit 21031226 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-04-01 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-04-01 |
Time |
17:49 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-04-01 |
Time |
17:49 |
Sent To |
|
|
Notes |
2021-04-01 17:50:20 | APPROVED, HALF ADDRESS WILL BE RETIRED DUE TO | | DEMOLITION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-07-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-07-21 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-07-21 |
Time |
15:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-07-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-07-20 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-07-20 |
Time |
09:14 |
Sent To |
|
|
Notes |
2021-07-20 09:15:40 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) DRAWING A4 SHOWS THE WIND SPEED FOR DESIGN AT 160 | | MPH - WIND SPEED SHOULD BE 170 MPH PER FBC WPB SECTION | | 120 | | 2) DRAWING A2 DOOR AND WINDOW SCHEDULE IS NOT CORRECT | | DOOR NUMBER 4 IS MISSING - OPENING NUMBER 3 SHOWS A | | DOOR IN PLACE OF A WINDOW (PLEASE CORRECT THE WINDOW | | AND DOOR SCHEDULE) | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-06-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-06-14 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-06-14 |
Time |
09:16 |
Sent To |
|
|
Notes |
2021-06-14 09:24:36 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) DRAWING A4 SHOWS THE WIND SPEED FOR DESIGN AT 160 | | MPH - WIND SPEED SHOULD BE 170 MPH PER FBC WPB SECTION | | 120 | | 2) DRAWING A2 DOOR AND WINDOW SCHEDULE IS NOT CORRECT | | DOOR NUMBER 4 IS MISSING - OPENING NUMBER 3 SHOWS A | | DOOR IN PLACE OF A WINDOW (PLEASE CORRECT THE WINDOW | | AND DOOR SCHEDULE) | | 3) PLEASE PROVIDE THE FRONT PAGE OF THE FLORIDA STATE | | PRODUCT APPROVAL FOR THE DOOR. | | 4) ALL PRODUCT APPROVALS SHOULD BE REVIEWED AND MARKED | | APPROVED BY THE BUILDING DESIGNER OF RECORD FBC WPB | | 107.3.4 | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-04-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-04-16 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-04-15 |
Time |
15:42 |
Sent To |
|
|
Notes |
2021-04-15 16:42:53 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE A SIGNED AND SEALED SURVEY SHOWING | | THE FOLLOWING INFORMATION 107.2.5 SITE PLAN. THE | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY | | PROPOSED WATER RETAINING SWALES) | | 2) PLEASE SHOW THE TUB AND SHOWER WALL FINISHES AND | | BOARDS TO COMPLY WITH FBC R307.2 AND R702.4.2 | | 3) PLEASE SHOW THE ATTIC VENTILATION TO COMPLY WITH FBC | | R806.1 | | 4) ROOFING WIND ZONES FOR THE 2020 CODE VERSION HAVE | | CHANGED - PLEASE INCLUDE WIND ZONES (2E) AND (2R) - SEE | | FBC FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE | | ZONES. | | 5) PLEASE SHOW THE LOCATIONS OF THE REQUIRED SMOKE | | ALARMS PER FBC R314.2 | | 6) PROVIDED PRODUCT APPROVAL (FL15210.01) HAS EXPIRED - | | PLEASE PROVIDE THE UPDATED VERSION FOR THE 2020 FBC - | | PLEASE PROVIDE THE FRONT PAGES OF THE FLORIDA STATE | | PRODUCT APPROVAL. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-07-22 |
|
|
Cont ID |
|
Sent By |
|
Date |
2021-07-22 |
Time |
|
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-07-22 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-06-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-06-08 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-06-08 |
Time |
16:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-04-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-09 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-09 |
Time |
15:09 |
Sent To |
|
|
Notes |
2021-04-09 15:17:58 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) NO SMOKE ALARMS SHOWN ON PLAN. R314/315 | | | | 2) OUTLET SPACING IN THE MIDDLE BEDROOM IS NOT TO CODE | | 210.52 | | | | 3) PLEASE INDICATE ON THE DRAWINGS THE LOCATION OF THE | | PANEL. 215.5 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2021-08-06 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-08-06 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-08-06 |
Time |
16:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2021-05-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-05-28 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-05-28 |
Time |
09:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-08-09 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-08-09 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-07-15 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
P |
Date |
2021-07-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-07-09 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-07-06 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-06-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-06-14 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-06-03 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-05-28 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-05-28 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-04-01 |
Time |
08:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-07-15 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-07-06 |
Time |
14:03 |
Sent To |
|
|
Notes |
2021-07-15 14:00:42 | RECEIPT MU-2021-33610 - $0.00 DUE | 2021-07-06 14:03:33 | 7/6/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-04-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-04-16 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-04-16 |
Time |
08:03 |
Sent To |
|
|
Notes |
2021-04-16 08:04:15 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-06-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-04 |
Time |
06:52 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-04 |
Time |
06:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-04-15 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-04-15 |
Time |
06:26 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-04-15 |
Time |
06:26 |
Sent To |
|
|
Notes |
2021-04-15 06:26:54 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-21031226 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN | | MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE | | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE | | SPECIFIC PROJECT WHICH HE OR SHE INSTALLS. | | PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A | | SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING | | CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING, | | OR | | THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL | | PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE | | COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER | | PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO | | THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1. | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | 2) PLEASE SHOW THE CONDENSATE DISPOSAL PIPING AND | | DISPOSAL LOCATION. FBC M 307 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2021-07-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-07-22 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-07-22 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-06-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-06-09 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-06-09 |
Time |
07:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-04-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-14 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-14 |
Time |
09:08 |
Sent To |
|
|
Notes |
2021-04-14 12:46:00 | 1ST REVIEW FBC-2020 RES. | | PERMIT- 21031226 | | 4/14/2021 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P-1: THE PLAN SHEET DOES NOT BEAR THE NAME, | | TITLE BLOCK, SIGNATURE OR SEAL OF THE PERSON WHO | | PREPARED THE DESIGN- SECTION 107.2.1 WPB. PLEASE NOTE | | THE FOLLOWING: | | ALL PLANS AND DOCUMENTS PREPARED BY A FL. LICENSED | | ENGINEER OR ARCHITECT ARE TO SIGNED, SEALED AND DATE | | ORIGINALS. PLANS TRANSMITTED ELECTRONICALLY SHALL BEAR | | THE DIGITAL SIGNATURES AND SEALS OF EITHER THE ENGINEER | | OR ARCHITECT- FL. STATUTES 471.025 & 481.221, AND FAC | | 61G15-23.005 & 61G1-16.005. | | FL. LICENSED CONTRACTORS OR QUALIFIERS WHO PREPARE | | DRAWINGS SHALL PROVIDE HIS/HER SIGNATURE ON THEM- | | SECTION 107.2.1 WPB, AND FLORIDA STATUTES 471.003(2)(H) | | & 471.025. A TITLE BLOCK ON THE DRAWING THAT INCLUDES | | CONTRACTOR OR COMPANY NAME AND LICENSE NUMBER IS ALSO | | REQUIRED. | | | | 2) P-1: PLEASE PROVIDE A SHOWER PAN DETAIL- SECTIONS | | P2709.1 & P2709.2 FBC RES. | | | | 3) P-1: PROVIDE A WATER HEATER EQUIPMENT SCHEDULE | | LISTING MAKE AND MODEL, GALLON SIZE AND EFFICIENCY | | RATING. THE DATA IN THE SCHEDULE SHALL MATCH THE DATA | | SHOWN ON THE ENERGY COMPLIANCE FORM R405-2020- | | 50-GALLON & EFF 0.96- TABLE C404.2 FBC EC. | | | | 4) P-1: THE RELIEF VALVE DISCHARGE PIPE SHALL TERMINATE | | NOT MORE THAN 6 INCHES AND NOT LESS THAN TWO TIMES THE | | DISCHARGE PIPE DIAMETER ABOVE THE FLOOR OR WASTE | | RECEPTOR FLOOD LEVEL RIM. THE DETAIL INCORRECTLY SHOWS | | THE DISCHARGE 4 INCHES FROM THE BOTTOM OF THE PAN NOT | | THE FLOOD LEVEL RIM. | | | | 5) P-1: PROVIDE A THERMAL EXPANSION TANK AND SHOW THE | | LOCATION IN THE WATER HEATER DETAIL- SECTION P2903.4 | | FBC RES. | | | | 6) P-1: PROVIDE HEAT TRAPS FOR THE VERTICAL INLET AND | | OUTLET PIPE RISERS AT THE WATER HEATER- SECTION | | R403.5.5 FBC EC. PLEASE NOTE THE TRAPS ARE NOT REQUIRED | | IF THE WATER HEATER IS EQUIPPED WITH INTEGRAL HEAT | | TRAPS. | | | | 7) PLEASE NOTE THAT WHERE A NEW POTABLE WATER SERVICE | | BACKFLOW PREVENTER IS REQUIRED: A FL. LICENSED PLUMBING | | CONTRACTOR SHALL OBTAIN A SEPARATE PERMIT FOR | | INSTALLATION OF THE BACKFLOW PREVENTER IN ACCORDANCE | | WITH SECTION 105.1 WPB AND SEC. 90-33 WPB CODE OF | | ORDINANCES. THE DEVICE SHALL BE TESTED AND CERTIFIED BY | | THE WPB UTILITIES DEPARTMENT PRIOR TO FINAL INSPECTION | | BY THE BUILDING DEPARTMENT. PLEASE CONTACT THE WPB | | UTILITIES CENTRAL OPERATIONS DEPT.AT 561-822-2210 FOR | | FURTHER INFORMATION. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P-IRRIGATE |
IRRIGATION REVIEW |
Rev No |
1 |
Status |
N |
Date |
2021-07-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-07-22 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-07-22 |
Time |
10:26 |
Sent To |
|
|
Notes |
2021-07-22 10:28:24 | IRRIGATION SHALL BE UNDER A SEPARATE PERMIT. COMPLETE | | PLANS AND SPECIFICATIONS SHALL BE SUBMITTED FOR REVIEW. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-06-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-06-14 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-06-14 |
Time |
09:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2021-04-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-04-16 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-04-16 |
Time |
08:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
P |
Date |
2021-07-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-07-28 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-07-28 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
F |
Date |
2021-07-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-07-21 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-07-21 |
Time |
15:48 |
Sent To |
|
|
Notes |
2021-07-21 15:56:38 | SIGNATURE REVIEW | | SURVEY 630 5TH.PDF DOES NOT SHOW AS ELECTRONICALLY | | SIGNED IN ADOBE READER - SIGNED AND SEALED DRAWINGS IN | | PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED | | BY THE ENGINEER OR ARCHITECT TO BE USED IN ELECTRONIC | | PLAN REVIEW. - OR - IF YOUR ARCHITECT OR ENGINEER DOES | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | DIVISION AT THE CITY HALL. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-07-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-08 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-08 |
Time |
17:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
N |
Date |
2021-06-29 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-29 |
Time |
06:33 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-29 |
Time |
06:33 |
Sent To |
|
|
Notes |
2021-06-29 06:33:47 | MECHANICAL CONTRACTOR SIGNED THE MECHANICAL DRAWING. ME |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-06-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-04 |
Time |
06:54 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-04 |
Time |
06:54 |
Sent To |
|
|
Notes |
2021-06-14 09:27:21 | SIGNATURE REVIEW | | DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER | | OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR | | - IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN | | ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL. | | | 2021-06-04 06:55:52 | SEE FIRST CYCLE COMMENTS. | | | | 2ND REVIEW FBC-2020 MECHANICAL | | PERMIT-21031226 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SHOW THE CORRECT LOCATION UNDER DESIGN | | INFORMATION (WEST PALM BEACH) ON THE MECHANICAL | | EQUIPMENT SIZING CALCULATIONS. | | | | 2) AN ENGINEER MUST DIGITALLY SIGN AND SEAL OR THE | | MECHANICAL CONTRACTOR HOLDING THE PERMIT TO INSTALL THE | | EQUIPMENT FOR THIS PROJECT MUST PRINT THEIR NAME AND | | SIGN THEIR NAME ON THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. F.S. 471.003(H) | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-04-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-09 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-09 |
Time |
15:18 |
Sent To |
|
|
Notes |
2021-04-09 15:22:49 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) PLAN IS NOT DIGITALLY SIGNED BY THE DESIGNER OF | | RECORD | | | | PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS | | 471.003(2)(H); 471.025; FBC 107.2.1 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-08-06 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-08-06 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-08-06 |
Time |
16:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-05-28 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2021-05-28 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-05-28 |
Time |
09:02 |
Sent To |
|
|
Notes |
|
|