Plan Review Details - Permit 21031226
Plan Review Stops For Permit 21031226
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-04-01 Cont ID  
Sent By cpuell Date 2021-04-01 Time 17:49 Rev Time 0.00
Received By cpuell Date 2021-04-01 Time 17:49 Sent To  
Notes
2021-04-01 17:50:20APPROVED, HALF ADDRESS WILL BE RETIRED DUE TO
 DEMOLITION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-07-21 Cont ID  
Sent By rmcphers Date 2021-07-21 Time 15:47 Rev Time 0.00
Received By rmcphers Date 2021-07-21 Time 15:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-07-20 Cont ID  
Sent By rmcphers Date 2021-07-20 Time 09:14 Rev Time 0.00
Received By rmcphers Date 2021-07-20 Time 09:14 Sent To  
Notes
2021-07-20 09:15:40NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DRAWING A4 SHOWS THE WIND SPEED FOR DESIGN AT 160
 MPH - WIND SPEED SHOULD BE 170 MPH PER FBC WPB SECTION
 120
 2) DRAWING A2 DOOR AND WINDOW SCHEDULE IS NOT CORRECT
 DOOR NUMBER 4 IS MISSING - OPENING NUMBER 3 SHOWS A
 DOOR IN PLACE OF A WINDOW (PLEASE CORRECT THE WINDOW
 AND DOOR SCHEDULE)
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-06-14 Cont ID  
Sent By rmcphers Date 2021-06-14 Time 09:16 Rev Time 0.00
Received By rmcphers Date 2021-06-14 Time 09:16 Sent To  
Notes
2021-06-14 09:24:36NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DRAWING A4 SHOWS THE WIND SPEED FOR DESIGN AT 160
 MPH - WIND SPEED SHOULD BE 170 MPH PER FBC WPB SECTION
 120
 2) DRAWING A2 DOOR AND WINDOW SCHEDULE IS NOT CORRECT
 DOOR NUMBER 4 IS MISSING - OPENING NUMBER 3 SHOWS A
 DOOR IN PLACE OF A WINDOW (PLEASE CORRECT THE WINDOW
 AND DOOR SCHEDULE)
 3) PLEASE PROVIDE THE FRONT PAGE OF THE FLORIDA STATE
 PRODUCT APPROVAL FOR THE DOOR.
 4) ALL PRODUCT APPROVALS SHOULD BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD FBC WPB
 107.3.4
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-04-16 Cont ID  
Sent By rmcphers Date 2021-04-16 Time 08:03 Rev Time 0.00
Received By rmcphers Date 2021-04-15 Time 15:42 Sent To  
Notes
2021-04-15 16:42:53NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE PROVIDE A SIGNED AND SEALED SURVEY SHOWING
 THE FOLLOWING INFORMATION 107.2.5 SITE PLAN. THE
 CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION
 FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING
 TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND
 EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT
 LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED
 FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE
 AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND
 DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN
 ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY
 LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY
 PROPOSED WATER RETAINING SWALES)
 2) PLEASE SHOW THE TUB AND SHOWER WALL FINISHES AND
 BOARDS TO COMPLY WITH FBC R307.2 AND R702.4.2
 3) PLEASE SHOW THE ATTIC VENTILATION TO COMPLY WITH FBC
 R806.1
 4) ROOFING WIND ZONES FOR THE 2020 CODE VERSION HAVE
 CHANGED - PLEASE INCLUDE WIND ZONES (2E) AND (2R) - SEE
 FBC FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE
 ZONES.
 5) PLEASE SHOW THE LOCATIONS OF THE REQUIRED SMOKE
 ALARMS PER FBC R314.2
 6) PROVIDED PRODUCT APPROVAL (FL15210.01) HAS EXPIRED -
 PLEASE PROVIDE THE UPDATED VERSION FOR THE 2020 FBC -
 PLEASE PROVIDE THE FRONT PAGES OF THE FLORIDA STATE
 PRODUCT APPROVAL.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-07-22 Cont ID  
Sent By   Date 2021-07-22 Time   Rev Time 0.00
Received By jleahy Date 2021-07-22 Time 10:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-06-08 Cont ID  
Sent By jleahy Date 2021-06-08 Time 16:53 Rev Time 0.00
Received By jleahy Date 2021-06-08 Time 16:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-04-09 Cont ID  
Sent By jleahy Date 2021-04-09 Time 15:15 Rev Time 0.00
Received By jleahy Date 2021-04-09 Time 15:09 Sent To  
Notes
2021-04-09 15:17:58ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) NO SMOKE ALARMS SHOWN ON PLAN. R314/315
  
 2) OUTLET SPACING IN THE MIDDLE BEDROOM IS NOT TO CODE
 210.52
  
 3) PLEASE INDICATE ON THE DRAWINGS THE LOCATION OF THE
 PANEL. 215.5

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2021-08-06 Cont ID  
Sent By fmittner Date 2021-08-06 Time 16:51 Rev Time 0.00
Received By fmittner Date 2021-08-06 Time 16:51 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-05-28 Cont ID  
Sent By fmittner Date 2021-05-28 Time 09:01 Rev Time 0.00
Received By fmittner Date 2021-05-28 Time 09:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-08-09 Cont ID  
Sent By pvalenti Date 2021-08-09 Time 07:46 Rev Time 0.00
Received By pvalenti Date 2021-07-15 Time 12:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status P Date 2021-07-09 Cont ID  
Sent By jleahy Date 2021-07-09 Time 16:10 Rev Time 0.00
Received By jleahy Date 2021-07-06 Time 13:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-14 Cont ID  
Sent By rmcphers Date 2021-06-14 Time 09:26 Rev Time 0.00
Received By rmcphers Date 2021-06-03 Time 16:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-28 Cont ID  
Sent By lmarchan Date 2021-05-28 Time 13:14 Rev Time 0.00
Received By lmarchan Date 2021-04-01 Time 08:37 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-07-15 Cont ID  
Sent By lmarchan Date 2021-07-15 Time 14:00 Rev Time 0.00
Received By lmarchan Date 2021-07-06 Time 14:03 Sent To  
Notes
2021-07-15 14:00:42RECEIPT MU-2021-33610 - $0.00 DUE
2021-07-06 14:03:337/6/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-04-16 Cont ID  
Sent By rmcphers Date 2021-04-16 Time 08:03 Rev Time 0.00
Received By rmcphers Date 2021-04-16 Time 08:03 Sent To  
Notes
2021-04-16 08:04:15PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-06-04 Cont ID  
Sent By medwards Date 2021-06-04 Time 06:52 Rev Time 0.00
Received By medwards Date 2021-06-04 Time 06:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-04-15 Cont ID  
Sent By medwards Date 2021-04-15 Time 06:26 Rev Time 0.00
Received By medwards Date 2021-04-15 Time 06:26 Sent To  
Notes
2021-04-15 06:26:541ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21031226
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN
 MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE
 MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE
 SPECIFIC PROJECT WHICH HE OR SHE INSTALLS.
 PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A
 SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING
 CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING,
 OR
 THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL
 PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE
 COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER
 PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO
 THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN.
  
 2) PLEASE SHOW THE CONDENSATE DISPOSAL PIPING AND
 DISPOSAL LOCATION. FBC M 307
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-07-22 Cont ID  
Sent By ccole Date 2021-07-22 Time 10:15 Rev Time 0.00
Received By ccole Date 2021-07-22 Time 09:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-06-09 Cont ID  
Sent By ccole Date 2021-06-09 Time 12:48 Rev Time 0.00
Received By ccole Date 2021-06-09 Time 07:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-04-14 Cont ID  
Sent By ccole Date 2021-04-14 Time 12:45 Rev Time 0.00
Received By ccole Date 2021-04-14 Time 09:08 Sent To  
Notes
2021-04-14 12:46:001ST REVIEW FBC-2020 RES.
 PERMIT- 21031226
 4/14/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P-1: THE PLAN SHEET DOES NOT BEAR THE NAME,
 TITLE BLOCK, SIGNATURE OR SEAL OF THE PERSON WHO
 PREPARED THE DESIGN- SECTION 107.2.1 WPB. PLEASE NOTE
 THE FOLLOWING:
 ALL PLANS AND DOCUMENTS PREPARED BY A FL. LICENSED
 ENGINEER OR ARCHITECT ARE TO SIGNED, SEALED AND DATE
 ORIGINALS. PLANS TRANSMITTED ELECTRONICALLY SHALL BEAR
 THE DIGITAL SIGNATURES AND SEALS OF EITHER THE ENGINEER
 OR ARCHITECT- FL. STATUTES 471.025 & 481.221, AND FAC
 61G15-23.005 & 61G1-16.005.
 FL. LICENSED CONTRACTORS OR QUALIFIERS WHO PREPARE
 DRAWINGS SHALL PROVIDE HIS/HER SIGNATURE ON THEM-
 SECTION 107.2.1 WPB, AND FLORIDA STATUTES 471.003(2)(H)
 & 471.025. A TITLE BLOCK ON THE DRAWING THAT INCLUDES
 CONTRACTOR OR COMPANY NAME AND LICENSE NUMBER IS ALSO
 REQUIRED.
  
 2) P-1: PLEASE PROVIDE A SHOWER PAN DETAIL- SECTIONS
 P2709.1 & P2709.2 FBC RES.
  
 3) P-1: PROVIDE A WATER HEATER EQUIPMENT SCHEDULE
 LISTING MAKE AND MODEL, GALLON SIZE AND EFFICIENCY
 RATING. THE DATA IN THE SCHEDULE SHALL MATCH THE DATA
 SHOWN ON THE ENERGY COMPLIANCE FORM R405-2020-
 50-GALLON & EFF 0.96- TABLE C404.2 FBC EC.
  
 4) P-1: THE RELIEF VALVE DISCHARGE PIPE SHALL TERMINATE
 NOT MORE THAN 6 INCHES AND NOT LESS THAN TWO TIMES THE
 DISCHARGE PIPE DIAMETER ABOVE THE FLOOR OR WASTE
 RECEPTOR FLOOD LEVEL RIM. THE DETAIL INCORRECTLY SHOWS
 THE DISCHARGE 4 INCHES FROM THE BOTTOM OF THE PAN NOT
 THE FLOOD LEVEL RIM.
  
 5) P-1: PROVIDE A THERMAL EXPANSION TANK AND SHOW THE
 LOCATION IN THE WATER HEATER DETAIL- SECTION P2903.4
 FBC RES.
  
 6) P-1: PROVIDE HEAT TRAPS FOR THE VERTICAL INLET AND
 OUTLET PIPE RISERS AT THE WATER HEATER- SECTION
 R403.5.5 FBC EC. PLEASE NOTE THE TRAPS ARE NOT REQUIRED
 IF THE WATER HEATER IS EQUIPPED WITH INTEGRAL HEAT
 TRAPS.
  
 7) PLEASE NOTE THAT WHERE A NEW POTABLE WATER SERVICE
 BACKFLOW PREVENTER IS REQUIRED: A FL. LICENSED PLUMBING
 CONTRACTOR SHALL OBTAIN A SEPARATE PERMIT FOR
 INSTALLATION OF THE BACKFLOW PREVENTER IN ACCORDANCE
 WITH SECTION 105.1 WPB AND SEC. 90-33 WPB CODE OF
 ORDINANCES. THE DEVICE SHALL BE TESTED AND CERTIFIED BY
 THE WPB UTILITIES DEPARTMENT PRIOR TO FINAL INSPECTION
 BY THE BUILDING DEPARTMENT. PLEASE CONTACT THE WPB
 UTILITIES CENTRAL OPERATIONS DEPT.AT 561-822-2210 FOR
 FURTHER INFORMATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P-IRRIGATE IRRIGATION REVIEW
Rev No 1 Status N Date 2021-07-22 Cont ID  
Sent By ccole Date 2021-07-22 Time 10:26 Rev Time 0.00
Received By ccole Date 2021-07-22 Time 10:26 Sent To  
Notes
2021-07-22 10:28:24IRRIGATION SHALL BE UNDER A SEPARATE PERMIT. COMPLETE
 PLANS AND SPECIFICATIONS SHALL BE SUBMITTED FOR REVIEW.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2021-06-14 Cont ID  
Sent By rmcphers Date 2021-06-14 Time 09:26 Rev Time 0.00
Received By rmcphers Date 2021-06-14 Time 09:26 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2021-04-16 Cont ID  
Sent By rmcphers Date 2021-04-16 Time 08:04 Rev Time 0.00
Received By rmcphers Date 2021-04-16 Time 08:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2021-07-28 Cont ID  
Sent By rmcphers Date 2021-07-28 Time 14:32 Rev Time 0.00
Received By rmcphers Date 2021-07-28 Time 14:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status F Date 2021-07-21 Cont ID  
Sent By rmcphers Date 2021-07-21 Time 15:48 Rev Time 0.00
Received By rmcphers Date 2021-07-21 Time 15:48 Sent To  
Notes
2021-07-21 15:56:38SIGNATURE REVIEW
 SURVEY 630 5TH.PDF DOES NOT SHOW AS ELECTRONICALLY
 SIGNED IN ADOBE READER - SIGNED AND SEALED DRAWINGS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 BY THE ENGINEER OR ARCHITECT TO BE USED IN ELECTRONIC
 PLAN REVIEW. - OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-07-08 Cont ID  
Sent By rmcdouga Date 2021-07-08 Time 17:04 Rev Time 0.00
Received By rmcdouga Date 2021-07-08 Time 17:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2021-06-29 Cont ID  
Sent By medwards Date 2021-06-29 Time 06:33 Rev Time 0.00
Received By medwards Date 2021-06-29 Time 06:33 Sent To  
Notes
2021-06-29 06:33:47MECHANICAL CONTRACTOR SIGNED THE MECHANICAL DRAWING. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-06-04 Cont ID  
Sent By medwards Date 2021-06-04 Time 06:54 Rev Time 0.00
Received By medwards Date 2021-06-04 Time 06:54 Sent To  
Notes
2021-06-14 09:27:21SIGNATURE REVIEW
 DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE
 READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED
 TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER
 OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR
 - IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN
 ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE
 FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL.
  
2021-06-04 06:55:52SEE FIRST CYCLE COMMENTS.
  
 2ND REVIEW FBC-2020 MECHANICAL
 PERMIT-21031226
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW THE CORRECT LOCATION UNDER DESIGN
 INFORMATION (WEST PALM BEACH) ON THE MECHANICAL
 EQUIPMENT SIZING CALCULATIONS.
  
 2) AN ENGINEER MUST DIGITALLY SIGN AND SEAL OR THE
 MECHANICAL CONTRACTOR HOLDING THE PERMIT TO INSTALL THE
 EQUIPMENT FOR THIS PROJECT MUST PRINT THEIR NAME AND
 SIGN THEIR NAME ON THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. F.S. 471.003(H)
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-04-09 Cont ID  
Sent By jleahy Date 2021-04-09 Time 15:22 Rev Time 0.00
Received By jleahy Date 2021-04-09 Time 15:18 Sent To  
Notes
2021-04-09 15:22:49ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) PLAN IS NOT DIGITALLY SIGNED BY THE DESIGNER OF
 RECORD
  
 PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS
 471.003(2)(H); 471.025; FBC 107.2.1
  

Review Stop Z ZONING
Rev No 2 Status P Date 2021-08-06 Cont ID  
Sent By fmittner Date 2021-08-06 Time 16:51 Rev Time 0.00
Received By fmittner Date 2021-08-06 Time 16:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-05-28 Cont ID  
Sent By aaponte Date 2021-05-28 Time 09:02 Rev Time 0.00
Received By fmittner Date 2021-05-28 Time 09:02 Sent To  
Notes
***NONE***