Plan Review Details - Permit 21031154
Plan Review Stops For Permit 21031154
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-06-23 Cont ID  
Sent By rmcdouga Date 2021-06-23 Time 13:59 Rev Time 0.00
Received By rmcdouga Date 2021-06-23 Time 13:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-04 Cont ID  
Sent By rmcdouga Date 2021-05-04 Time 14:57 Rev Time 0.00
Received By rmcdouga Date 2021-05-04 Time 13:34 Sent To  
Notes
2021-05-04 14:06:48PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT REQUIRED COMPONENT AND CLADDING DESIGN
 PRESSURES FOR THE OPENINGS THAT HAVE BEEN PREPARED BY A
 FLORIDA LICENSED DESIGN PROFESSIONAL. THE DOCUMENTS ARE
 REQUIRED TO BE DIGITALLY SIGNED BY THE DESIGN
 PROFESSIONAL IF SUBMITTED ELECTRONICALLY AND THE DESIGN
 PROFESSIONAL'S ORIGINAL HANDWRITTEN SIGNATURE IF PAPER
 DOCUMENTS ARE SUBMITTED. FS 471 & FAC 61G15 /FS 481 &
 FAC 61G1
  
 2) ONE OR BOTH OF THESE CHURCH BUILDINGS MAY BE RISK
 CATEGORY III. THIS WILL NEED TO BE DETERMINED BY THE
 DESIGN PROFESSIONAL AND REFLECTED IN THE COMPONENT AND
 CLADDING PRESSURES. FBC BUILDING 1604.5
  
 3) SOME OF THESE DOORS MAY BE REQUIRED EXIT DOORS THAT
 ARE REQUIRED TO OPEN IN THE DIRECTION OF EXIT TRAVEL
 AND HAVE PANIC HARDWARE. SPECIFY THE SWING AND HARDWARE
 ON THE EXISTING DOORS AND THE REPLACEMENT DOORS. THEY
 CAN NOT BE ANY LESS RESTRICTIVE THAN THE EXISTING. FBC
 EXISTING BUILDING 704.1
  
 4) HI-LIGHT OR CIRCLE THE SPECIFIC DOOR SIZES, GLASS
 TYPE, DESIGN PRESSURE AND OTHER ITEMS THAT APPLY TO THE
 DOORS THAT WILL BE INSTALLED. FBC AMENDMENTS 107.2.1
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-23 Cont ID  
Sent By rmcdouga Date 2021-06-23 Time 13:59 Rev Time 0.00
Received By rmcdouga Date 2021-06-09 Time 09:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-04 Cont ID  
Sent By rmcdouga Date 2021-05-04 Time 14:58 Rev Time 0.00
Received By rmcdouga Date 2021-04-23 Time 08:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-06-23 Cont ID  
Sent By rmcdouga Date 2021-06-23 Time 13:59 Rev Time 0.00
Received By rmcdouga Date 2021-06-23 Time 13:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-05-04 Cont ID  
Sent By rmcdouga Date 2021-05-04 Time 14:58 Rev Time 0.00
Received By rmcdouga Date 2021-05-04 Time 13:34 Sent To  
Notes
2021-05-04 14:58:51ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE
 THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM.
 YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND
 SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC
 PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE
 CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT
 TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL
 HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE
 DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE
 SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 &
 61G15