Plan Review Stops For Permit 21031128 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-04-08 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-04-08 |
Time |
09:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-05-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-05-18 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-05-18 |
Time |
05:40 |
Sent To |
|
|
Notes |
2021-05-18 09:24:41 | PLAN REVIEW BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 2ND REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | PREVIOUS COMMENTS. | | | | | | 1. CORRECTED | | | | 2. CORRECTED | | | | 3. CORRECTED | | | | 4. PROVIDE A ROOF FRAMING PLAN. (PROVIDE FASTENER | | SCHEDULE FOR ROOF SHEATHING BASED ON EACH PRESSURE | | ZONE). | | TABLE R301.2.1.2 | | WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD | | STRUCTURAL PANELS. | | | | | | 5. CORRECTED | | | | | | NEW COMMENTS: | | | | 6. NOA'S LISTED ON DOOR SCHEDULE DO NOT MATCH NOA'S | | SHOWN ON ELEVATION DRAWING. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-20 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-19 |
Time |
09:42 |
Sent To |
|
|
Notes |
2021-04-20 13:19:12 | PLAN REVIEW BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE A SITE DRAINAGE PLAN. | | FBC R401.3 SITE DRAINAGE | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | FBC R401.3 DRAINAGE. | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | DOES NOT CREATE A HAZARD. | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | INCHES WITHIN THE FIRST 10 FEET. | | | | 2. NOA'S LISTED ON WINDOW SCHEDULE DO NOT MATCH NOA'S | | SHOWN ON ELEVATION DRAWING. PLEASE CLARIFY. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 3. PROVIDE NOA FOR OVERHEAD DOOR. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 4. PROVIDE A ROOF FRAMING PLAN. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 5. SPECIFY ROOF COVERING. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-20 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-19 |
Time |
09:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-20 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-20 |
Time |
12:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-05-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-05-18 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-05-18 |
Time |
05:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-20 |
Time |
07:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-19 |
Time |
15:18 |
Sent To |
|
|
Notes |
2021-04-20 07:48:16 | PLAN REVIEW / FUEL GAS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: | | PROVISO: A SEPERATE GAS PERMIT IS REQUIRED FOR THE | | GENERATOR. PROVISO ON PLAN PAGE P-1.03. | | | | 1. SUBMIT GAS SIZING TABLES FOR POLYETHYLENE PLASTIC | | PIPING. | | G2413.3 (402.3)SIZING AND G2413.4 (402.4)SIZING TABLES | | AND EQUATIONS. | | | | 2. PROVIDE LENGTH OF 1 1/2" SCH 40 PIPE FROM METER TO | | FIRST TEE. | | G2413.4.1, G2413.4.2. AND . 402.4.1, 402.4.2. | | | | 3. SUBMIT MANUFACTURERS SPECIFICATION | | SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO | | VERIFY COMPLIANCE WITH 2017 FBC FUEL GAS SEC.305.1 OR | | 2017 FBC FUEL GAS RES. SEC. G2408.1. | | | | 4. SUBMIT GAS REGULATOR SPECIFICATIONS. 2017 FBC FUEL | | GAS SEC.305.1 OR 2017 FBC FUEL GAS RES. SEC. G2408.1. | | | | NOTICE: REGULATORS SHALL HAVE A UNION INSTALLED WITHIN | | 1 FOOT OF EITHER SIDE OF THE REGULATOR FBC FG 410.2 | | | | NOTICE: REGULATORS SHALL BE LOCATED PER 409.1.3. | | | | NOTICE: HOOD FOR KITCHEN GAS GRILL SHALL COMPLY WITH | | 623.5. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-05-27 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-05-27 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-05-14 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-20 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-07 |
Time |
14:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-20 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-20 |
Time |
12:39 |
Sent To |
|
|
Notes |
2021-04-20 12:40:39 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-05-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-05-18 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-05-18 |
Time |
05:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-20 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-19 |
Time |
09:42 |
Sent To |
|
|
Notes |
2021-04-20 13:23:54 | PLAN REVIEW / MECHANICAL | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. WALL TYPE INSULATION R-VALUE IS MISSING FROM FORM | | 405. | | 2. WALL TYPE INSULATION IS MISSING FROM FORM 405 EPL | | CARD. | | 3. EPL CARD SHALL BE SIGNED BY BUILDER. | | R101.5.1.1.1BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE CODE OFFICIAL TO DEMONSTRATE | | CODE COMPLIANCE BY THIS METHOD. ALTERNATIVELY, A | | FLORIDA RESCHECK COMPUTER PRINTOUT MAY BE SUBMITTED TO | | DEMONSTRATE COMPLIANCE BY SECTIONS R402, R403 AND R404. | | | | 4. PROVIDE CONDENSATE DISPOSAL DETAIL. | | M1411.3 CONDENSATE DISPOSAL. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-05-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-05-18 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-05-18 |
Time |
05:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-20 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-19 |
Time |
09:42 |
Sent To |
|
|
Notes |
2021-04-20 13:55:33 | PLAN REVIEW / PLUMBING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE SHOWER PAN DETAIL. | | P2709.1 SHOWER PAN CONSTRUCTION. FBC 107.2.1; P2709.3 | | SHOWER PAN LINING INSTALLATION. | | | | 2. P2708.4SHOWER CONTROL VALVES. INDIVIDUAL SHOWER AND | | TUB/ SHOWER COMBINATION VALVES SHALL BE EQUIPPED WITH | | CONTROL VALVES OF THE PRESSURE-BALANCE, | | THERMOSTATIC-MIXING OR COMBINATION | | PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE TYPES WITH A | | HIGH LIMIT STOP IN ACCORDANCE WITH ASSE 1016/ASME | | A112.1016/CSA B125.16. THE HIGH LIMIT STOP SHALL BE SET | | TO LIMIT THE WATER TEMPERATURE TO NOT GREATER THAN | | 120?F (49?C). IN-LINE THERMOSTATIC VALVES SHALL NOT BE | | USED FOR COMPLIANCE WITH THIS SECTION. | | NOTE: YOU MAY PLACE THIS ON YOUR PLAN. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2021-05-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-05-18 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-05-18 |
Time |
05:40 |
Sent To |
|
|
Notes |
2021-05-18 10:28:33 | PLAN REVIEW / ROOFING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 2ND REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | PREVIOUS COMMENTS. | | | | | | 1. COMPLETE. | | | | 2. PROVIDE FASTENER SCHEDULE BASED ON ROOF PRESSURE | | ZONES. (NOT ADDRESSED) | | TABLE R301.2.1.2 | | WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD | | STRUCTURAL PANELS. | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | COMPONENTS. (R905.1.1UNDERLAYMENT. | | UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL | | CONFORM ), TO THE APPLICABLE STANDARDS LISTED IN THIS | | CHAPTER. | | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-20 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-19 |
Time |
09:42 |
Sent To |
|
|
Notes |
2021-04-20 10:26:18 | PLAN REVIEW / ROOFING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE ROOF PRESSURE DIAGRAHM PER FIGURE R301.2(7) | | COMPONENT AND CLADDING PRESSURE ZONES PER 2020 FBC 7TH | | ED. | | R301.2.1.1WIND DESIGN REQUIRED. | | | | 2. PROVIDE FASTENER SCHEDULE BASED ON ROOF PRESSURE | | ZONES. | | TABLE R301.2.1.2 | | WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD | | STRUCTURAL PANELS. | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | COMPONENTS. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-05-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-05-18 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-05-18 |
Time |
05:40 |
Sent To |
|
|
Notes |
2021-05-18 09:26:30 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2017 | | | | 2ND REVIEW | | | | REF: ARCHITECTURAL AND STRUCTURAL PLANS | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-04-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-19 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-19 |
Time |
09:42 |
Sent To |
|
|
Notes |
2021-04-19 15:54:53 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2017 | | | | 1ST REVIEW | | | | REF: ARCHITECTURAL AND STRUCTURAL PLANS | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-05-26 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2021-05-26 |
Time |
|
Sent To |
|
|
Notes |
2021-05-26 17:02:21 | **************************************ZONING | | REVIEW********************************* | | | | | | PROVIDE THE SETBACK ON THE SOUTHSIDE FROM EDMOR ON THE | | SITE PLAN, LIKE THE FRONT SETBACK IS LABELED. | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-04-19 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2021-04-19 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2021-04-19 |
Time |
|
Sent To |
|
|
Notes |
2021-04-19 10:47:54 | ******************************************ZONING | | REVIEW************************************************* | | | | THE SETBACK ON OLIVE IS REQUIRED TO BE A MINIMUM OF 25 | | FEET BECAUSE BASED ON OUR CODE, THE FRONT LOT LINE IS | | ON OLIVE. PROVIDE THE SETBACK FOR THE ADDITION ON THE | | SITE PLAN FROM OLIVE. | | | | LOT LINE, FRONT, MEANS THE LINE SEPARATING A LOT FROM A | | STREET, ROAD OR OTHER PUBLIC OR PRIVATE RIGHT-OF-WAY. | | AT ALL CORNER LOTS, THE FRONT LOT LINE SHALL BE THE | | PUBLIC STREET RIGHT-OF-WAY LINE WHICH POSSESSES THE | | NARROWEST LENGTH. THE OTHER PUBLIC STREET RIGHT-OF-WAY | | SHALL BE CONSIDERED THE CORNER LOT LINE. | | | | LANDSCAPE CODE HAS BEEN TRIGGERED. | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | PERMIT. SHOWING THE FOLLOWING: | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | BEACH | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | GROSS LOT SQUARE FOOTAGE MINUS | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|