Plan Review Details - Permit 21030992
Plan Review Stops For Permit 21030992
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2021-06-25 Cont ID  
Sent By cpuell Date 2021-06-25 Time 13:27 Rev Time 0.00
Received By cpuell Date 2021-06-25 Time 13:27 Sent To  
Notes
2021-06-25 13:28:54NEW PLANS SUBMITTED, WITH NO CABANA ATTACHED. 250
 ALHAMBRA PL ADDRESS IS GOOD FOR THE PROJECT.

Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-04-29 Cont ID  
Sent By cpuell Date 2021-04-29 Time 15:57 Rev Time 0.00
Received By cpuell Date 2021-04-29 Time 15:57 Sent To  
Notes
2021-04-29 15:58:05PER ZONING, GUEST HOUSE IS NOW A CABANA, FRONT BUILDING
 ADDRESS OK.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-04-01 Cont ID  
Sent By cpuell Date 2021-04-01 Time 17:35 Rev Time 0.00
Received By cpuell Date 2021-04-01 Time 17:35 Sent To  
Notes
2021-04-01 17:37:28NO ISSUE WITH THE FRONT HOUSE HAVING THE ADDRESSED OF
 209 SUMMA ST HOWEVER A NEW ADDRESS WILL NEED TO BE
 GIVEN TO THE GUEST HOUSE, THIS WILL BE SUBJECT TO
 APPROVAL FROM ZONING FOR THE ADDITIONAL UNIT. PLEASE
 EMAIL [email protected] ONCE ZONING HAS APPROVED THE GUEST
 HOUSE SO THAT AN ADDRESS CAN BE ESTABLISHED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-07-21 Cont ID  
Sent By cthroop Date 2021-07-21 Time 13:46 Rev Time 0.00
Received By cthroop Date 2021-07-21 Time 13:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-06-01 Cont ID  
Sent By cthroop Date 2021-06-01 Time 13:38 Rev Time 0.00
Received By cthroop Date 2021-06-01 Time 07:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-04-14 Cont ID  
Sent By cthroop Date 2021-04-14 Time 15:05 Rev Time 0.00
Received By cthroop Date 2021-04-14 Time 05:41 Sent To  
Notes
2021-04-14 15:16:12PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 1&2 FAMILY - SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: CITY POLICY REQUIRES A SEPERATE PERMIT FOR EACH
 STRUCTURE ON AN INDIVIDUAL PARCELL. SUBMIT PERMIT
 APPLICATION FOR GUEST HOUSE. ALL PLANS WILL REMAIN
 UNDER MAIN HOUSE PERMIT 21030992.
 SEPERATE INSPECTIONS WILL BE REQUIRED. SEPERATE C/O
 WILL BE ISSUED.
  
 1. PROVIDE FINISHED FLOOR ELEVATION.
 R403.1.7.3 FOUNDATION ELEVATION.
 ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION
 SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER
 AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED
 DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2
 PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO
 THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN
 BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF
 DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT
 ALL LOCATIONS ON THE SITE.
  
 FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION
 PLAN AND/OR FLOOR PLAN.
  
 2. PROVIDE SITE DRAINAGE PLAN.
 FBC R401.3 SITE DRAINAGE
 PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH
 FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 3. SOILS REPORT NOT REQUIRED. PROVIDE DENSITY TEST AT
 FOUNDATION INSPECTION.
  
 REF. PRODUCT APPROVAL AFFIDAVIT FOR THE FOLLOWING:
  
 4. THE FOLLOWING PRODUCT APPROVALS ARE MISSING THE
 COVER LETTER. THE COVER SHEET PROVIDES THE APPROVAL
 NUMBER, CODE VERSION, AND STATUS, FBC R 301.
 FL17184.1
  
 5. THE FOLLOWING PRODUCT APPROVALS ARE NOT LISTED ON
 THE PRODUCT APPROVAL AFFIDAVIT. DESIGNER SHALL REVIEW
 AND APPROVE THE FOLLOWING:
 FL16709-R7, FL6332-R9, FL11288-R18.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-06-28 Cont ID  
Sent By jleahy Date 2021-06-28 Time 13:30 Rev Time 0.00
Received By jleahy Date 2021-06-28 Time 13:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-04-05 Cont ID  
Sent By jleahy Date 2021-04-05 Time 17:39 Rev Time 0.00
Received By jleahy Date 2021-03-31 Time 17:11 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status N Date 2021-07-06 Cont ID  
Sent By ccole Date 2021-07-06 Time 17:28 Rev Time 0.00
Received By ccole Date 2021-07-06 Time 17:28 Sent To  
Notes
2021-07-06 17:35:50GAS TO BE UNDER SEPARATE PER GENERAL CONTRACTOR'S
 PREVIOUS REQUEST ON 5/13/21. A GAS REVIEW WAS NOT
 COMPLETED UNDER THIS PERMIT.
 COMPLETE PLANS INCLUDING A GAS RISER DRAWING, GAS
 PIPING LAYOUT DRAWING, APPLIANCE SPECIFICATIONS,
 COMBUSTION AIR AND VENTING PLANS, WATER HEATER
 INSTALLATION CLEARANCES AND CONDENSATION DISPOSAL
 DETAILS SHALL BE SUBMITTED UNDER SEPATRATE PERMIT FOR
 REVIEW - SECTION 107.2.1 WPB.
 CCOLE- 7/6/2021

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2021-05-13 Cont ID  
Sent By ccole Date 2021-05-13 Time 14:51 Rev Time 0.00
Received By ccole Date 2021-05-13 Time 13:31 Sent To  
Notes
2021-05-13 14:52:55GAS TO BE UNDER SEPARATE PER GENERAL CONTRACTOR'S
 REQUEST. A GAS REVIEW WAS NOT COMPLETED UNDER THIS
 PERMIT.
 CCOLE- 5/13/2021

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-04-12 Cont ID  
Sent By ccole Date 2021-04-12 Time 15:17 Rev Time 0.00
Received By ccole Date 2021-04-12 Time 14:25 Sent To  
Notes
2021-04-12 15:18:111ST REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 21030992
 4/12/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET GS-1 GAS RISER: PROVIDE THE BRANCH LENGTH
 MEASUREMENTS, CUT PIPE LENGTH MEASUREMENTS, AND THE
 TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER TO
 THE MOST REMOTE OUTLET- SECTION G2413.4.1 & G2413.4.2
 FBC RES.
  
 2) GS-1 GAS RISER: LIST THE PIPE SIZING TABLES USED TO
 DESIGN THE SYSTEM- SECTION G2413.4.
  
 3) GS-1: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 TANKLESS WATER HEATERS, COOKTOP AND DRYER- SECTIONS
 G2408.1, G2438.1 G2448.1.
  
 4) GS-1: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE
 COOKTOP- SECTION G2407.1
  
 5) GS-1: INDICATE HOW MAKEUP AIR WILL BE PROVIDED FOR
 THE GAS DRYER- SECTION G2439.5.
  
 6) GS-1: PROVIDE ELEVATIONS VIEW OF THE TANKLESS WATER
 HEATERS INDICATING INSTALLATION LOCATIONS AND CLEARANCE
 DISTANCE MEASUREMENTS FROM GRADE, OVERHEAD
 CONSTRUCTION, AND AIR INTAKES AND WINDOW AND DOOR
 OPENINGS INTO THE BUILDING- SECTIONS G2427.1 & G2448.1.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-07-21 Cont ID  
Sent By cthroop Date 2021-07-21 Time 13:46 Rev Time 0.00
Received By cthroop Date 2021-06-25 Time 12:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-01 Cont ID  
Sent By cthroop Date 2021-06-01 Time 13:38 Rev Time 0.00
Received By cthroop Date 2021-05-04 Time 15:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-04-22 Cont ID  
Sent By rmcphers Date 2021-04-22 Time 07:53 Rev Time 0.00
Received By rmcphers Date 2021-03-24 Time 11:27 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-08-03 Cont ID  
Sent By lmarchan Date 2021-08-03 Time 16:39 Rev Time 0.00
Received By lmarchan Date 2021-07-22 Time 14:24 Sent To  
Notes
2021-07-27 14:11:27RECEIPT MU-2021-36128 - $546.52 PAID
2021-07-22 14:24:467/22/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-04-14 Cont ID  
Sent By cthroop Date 2021-04-14 Time 13:00 Rev Time 0.00
Received By cthroop Date 2021-04-14 Time 13:00 Sent To  
Notes
2021-04-14 13:01:46MAIN HOUSE 21030992
  
 PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected]
  
 NOTICE: YOU WILL BE REQUIRED TO SUBMIT A SEPERATE
 PERMIT APPLICATION FOR THE GUEST HOUSE. A SECOND IMPACT
 FEE QUESTIONAIRE WILL ALSO BE REQUIRED. CT
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-06-28 Cont ID  
Sent By medwards Date 2021-06-28 Time 17:00 Rev Time 0.00
Received By medwards Date 2021-06-28 Time 17:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-05-12 Cont ID  
Sent By medwards Date 2021-05-12 Time 16:25 Rev Time 0.00
Received By medwards Date 2021-05-12 Time 16:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-04-05 Cont ID  
Sent By medwards Date 2021-04-05 Time 06:39 Rev Time 0.00
Received By medwards Date 2021-04-05 Time 06:39 Sent To  
Notes
2021-04-05 06:40:101ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21030992
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE MECHANICAL CONTRACTOR MUST SIGN FOR THE
 MECHANICAL SIZING CALCULATIONS OR A FLORIDA LICENSED
 ENGINEER MAY SEAL AND STAMP EACH. FS 471.003 (H): THE
 MECHANICAL EQUIPMENT SIZING CALCULATIONS ALONG WITH THE
 MECHANICAL SYSTEM DESIGN MUST BE DESIGNED BY A FLORIDA
 LICENSED ENGINEER OR THE MECHANICAL CONTRACTOR THAT
 HOLDS THE PERMIT FOR THE SPECIFIC PROJECT WHICH HE OR
 SHE INSTALLS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-07-09 Cont ID  
Sent By ccole Date 2021-07-06 Time 18:00 Rev Time 0.00
Received By ccole Date 2021-07-06 Time 14:43 Sent To  
Notes
2021-07-06 18:01:20 
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-05-13 Cont ID  
Sent By ccole Date 2021-05-13 Time 14:30 Rev Time 0.00
Received By ccole Date 2021-05-13 Time 13:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-04-12 Cont ID  
Sent By ccole Date 2021-04-12 Time 14:23 Rev Time 0.00
Received By ccole Date 2021-04-12 Time 13:17 Sent To  
Notes
2021-04-12 14:23:541ST REVIEW FBC-2020 RES.
 PERMIT- 21030992
 4/12/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET GS-1: PLEASE SHOW A 2 IN. STANDPIPE AND A 3
 IN. VERTICAL STACK FOR THE WASHING MACHINE- SECTION
 406.2 FBC P.
  
 2) GS-1: PROVIDE ELECTRIC AND GAS WATER HEATER
 EQUIPMENT SCHEDULES LISTING MAKES AND MODELS, GALLON
 SIZE FOR STORAGE TANKS, AND EFFICIENCY RATINGS- TABLE
 C404.2 FBC EC. PLEASE NOTE THAT THE ENERGY COMPLOIANCE
 FORM FOR THE GUEST HOUSE SHOWS A GAS WATER HEATER,
 HOWEVER THE PLANS SHOW AN ELECTRIC WATER HEATER.
  
 3) GS-1: PROVIDE SHOWER PAN DETAILS- SECTION P2709.1 &
 P2709.2 FBC RES.
  
 4) GS-1: PROVIDE AN ELECTRIC WATER HEATER PIPING DETAIL
 SHOWING THE THERMAL EXPANSION TANK, PAN, AND PAN DRAIN
 RUN AND DRAIN TERMINATION LOCATION- SECTIONS P2801.6 &
 P2903.4 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2021-07-21 Cont ID  
Sent By cthroop Date 2021-07-21 Time 13:46 Rev Time 0.00
Received By cthroop Date 2021-07-21 Time 13:35 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2021-06-01 Cont ID  
Sent By cthroop Date 2021-06-01 Time 13:38 Rev Time 0.00
Received By cthroop Date 2021-06-01 Time 07:00 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2021-04-14 Cont ID  
Sent By cthroop Date 2021-04-14 Time 14:58 Rev Time 0.00
Received By cthroop Date 2021-04-14 Time 05:41 Sent To  
Notes
2021-04-14 15:05:44PLAN REVIEW / ROOFING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PRODUCT APPROVAL FOR ROOF TILE SUBMITTED FOR REVIEW
 IS NOT THE PRODUCT APPROVAL LISTED IN THE SUBMITTAL
 AFFIDAVIT. WHICH ONE WILL BE INSTALLED?
  
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-07-15 Cont ID  
Sent By medwards Date 2021-06-29 Time 06:08 Rev Time 0.00
Received By medwards Date 2021-06-29 Time 06:08 Sent To  
Notes
2021-06-29 06:14:09 
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-05-05 Cont ID  
Sent By equinone Date 2021-05-05 Time 11:29 Rev Time 0.00
Received By equinone Date 2021-05-05 Time 11:29 Sent To  
Notes
2021-05-05 11:29:33ORIGINAL SIGNED AND SEALED PAPER DOCUMENT ROUTED TO
 STORAGE. EQ

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-03-25 Cont ID  
Sent By medwards Date 2021-03-25 Time 08:30 Rev Time 0.00
Received By medwards Date 2021-03-25 Time 08:08 Sent To  
Notes
2021-03-25 08:30:52ORIGINAL SIGNED AND SEALED PAPER DOCUMENT ROUTED TO
 STORAGE. ME

Review Stop Z ZONING
Rev No 3 Status P Date 2021-07-06 Cont ID  
Sent By rthermid Date 2021-07-06 Time   Rev Time 0.00
Received By rthermid Date 2021-07-06 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-05-20 Cont ID  
Sent By rthermid Date 2021-05-20 Time   Rev Time 0.00
Received By rthermid Date 2021-05-20 Time   Sent To I
Notes
2021-05-20 08:52:24ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 5/20/2021
 ________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. A SEPERATE BUILDING PERMIT IS TO BE OBTAINED FOR
 LANDSCAPE, DRIVEWAY PERMITS AND ANY ADDITIONAL WORK TO
 BE COMPLETED ON SITE.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status P Date 2021-04-21 Cont ID  
Sent By rthermid Date 2021-04-21 Time   Rev Time  
Received By rthermid Date 2021-04-21 Time   Sent To I
Notes
2021-04-21 09:21:07THE PROPOSED "GUEST HOUSE" ON THE PLANS IS MISLABELLED.
 IT IS A "POOL CABANA" WITH KITCHENETTE.
 MAIN STRUCTURE APPROVED.
  