Plan Review Stops For Permit 21030694 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-06-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-07 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-06-07 |
Time |
13:31 |
Sent To |
|
|
Notes |
2021-06-07 14:58:54 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2017 | | | | 3RD REVIEW | | RESULTS: DENIED | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: DIGITAL SIGNATURE IS A COPY. | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-05-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-05-20 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-05-20 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-04-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-02 |
Time |
06:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-02 |
Time |
06:09 |
Sent To |
|
|
Notes |
2021-04-02 06:55:31 | PLAN REVIEW BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE COLUMN FOOTING STRUCTURAL DETAIL. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2. PROVIDE STRUCTURAL DETAIL OF COLUMNS. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 3. PROVIDE STRUCTURAL DETAIL OF V-TRACK FOR GATES. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 4. PROVIDE SITE SPECIFIC DESIGN WIND LOADS PER: | | FBC RESIDENTIAL CHPT. 3 | | R301.2.1 WIND DESIGN CRITERIA. | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | FROM FIGURE R301.2(4). | | | | -OR- | | ASCE 7-16 (VULT 170MPH 3 SEC GUST / VASD 132MPH) | | | | 5. PLAN SUBMITTED INDICATES LIGHTS ON TOP OF COLUMNS. A | | SEPERATE ELECTRICAL PERMIT WILL BE REQUIRED. | | PERMITS - 105.1 REQUIRED. | | | | NOTICE: STRUCTURAL DETAILS SHALL BEAR THE NAME AND | | SIGNATURE OF DESIGNER. SEE SIGNATURE REVIEW COMMENTS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2021-03-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-03-30 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-03-30 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-06-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-16 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-06-01 |
Time |
08:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-05-28 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-05-28 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-05-10 |
Time |
14:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-04-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-02 |
Time |
06:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-03-16 |
Time |
13:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-16 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-06-16 |
Time |
09:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2021-06-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-07 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-06-07 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-05-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-05-20 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-05-20 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-04-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-02 |
Time |
06:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-02 |
Time |
06:09 |
Sent To |
|
|
Notes |
2021-04-02 06:57:02 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: STRUCTURAL DETAILS REQUIRED. | | | | 1. THE OWNER/BUILDER, CONTRACTOR OR DESIGNER OF RECORD | | SHALL PROVIDE THEIR PRINTED NAME AND SIGNATURE ON PLAN | | SHEETS UNDER THEIR AUTHORITY. | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, SECTION 107.2.1. | | | | 2. EITHER UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL | | WITH SIGNATURE OF DESIGNER AS APPLICABLE; USE THE | | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT OR DROP | | OFF (OR MAIL) ONE PAPER ORIGINAL WITH CONTRACTORS/O/B | | SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | 481, F.S. & 61G1. | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-06-16 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-06-16 |
Time |
09:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2021-05-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-05-28 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-05-28 |
Time |
13:55 |
Sent To |
|
|
Notes |
2021-05-28 13:56:09 | APPROVED AT THE 4' HEIGHT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-05-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-05-28 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-05-28 |
Time |
10:13 |
Sent To |
|
|
Notes |
2021-05-28 10:14:05 | PLANS SHOW 4'6" IN HEIGHT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-03-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-03-30 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-03-30 |
Time |
10:28 |
Sent To |
|
|
Notes |
2021-03-30 10:29:03 | WALLS CANNOT EXCEED 4' IN HEIGHT WITHIN FIRST 25' OF | | PROPERTY. PLANS SHOW 6' |
|
|