Plan Review Details - Permit 21030651
Plan Review Stops For Permit 21030651
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-06-16 Cont ID  
Sent By cthroop Date 2021-06-16 Time 06:23 Rev Time 0.00
Received By cthroop Date 2021-06-16 Time 06:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-15 Cont ID  
Sent By jleahy Date 2021-06-15 Time 08:03 Rev Time 0.00
Received By jleahy Date 2021-06-15 Time 07:55 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-07-27 Cont ID  
Sent By abelisle Date 2021-07-27 Time 14:38 Rev Time 0.00
Received By abelisle Date 2021-07-27 Time 12:07 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-06-21 Cont ID  
Sent By tklarge Date 2021-06-21 Time 09:55 Rev Time 0.00
Received By tklarge Date 2021-06-17 Time 10:26 Sent To  
Notes
2021-06-21 09:07:091) SHOW THE DISTANCE OF THE LP TANK FROM THE DRIVEWAY.
 IF THE TANK IS WITHIN 10 FT. OF THE DRIVEWAY, THE TANK
 SHALL BE BURIED A MNIMUM OF 18 INCHES BELOW GRADE PER
 NFPA 58 SEC. 6.8.6.1 (B).
 2) IF THE LP TANK IS WITHIN 10 FT. OF THE DRIVEWAY,
 VEHICULAR BARRIER PROTECTION SHALL BE PROVIDED FOR THE
 CONTAINER'S FITTING HOUSING, HOUSING COVER, CONTAINER
 CONNECTIONS, AND PIPING.NFPA 58, SEC.6.8.6.1(C).
 3) THE PERMIT IS FOR LP GAS BUT THE SUBMITTED GAS
 SIZING TABLES ARE FOR NATURAL GAS. SUBMIT THE CORRECT
 SIZING TABLES.
 4) WHERE CONNECTED TO RIGID PIPING, A UNION IS REQUIRED
 ON THE GAS PIPING WITHIN 1 FT. UPSTREAM OR DOWNSTREAM
 OF THE REGULATORS.FBC-FUEL GAS SEC.410.2 (7).
 5) INDICATE ON THE PLAN THE TYPE OF AUGER ANCHOR TO BE
 USED BASED ON THE CLASS OF SOIL FROM THE TABLE FROM TIE
 DOWN ENGINEERING. WPB AMEND. TO FBC SEC. 107.2.1.
 6) THE GAS PLAN STATES THE GAS CODES ARE BASED ON 402.4
 SERIES OF FBC CODES. THERE ARE NO 402.4 SERIES OF FBC
 CODES. CLARIFY.
 7) THE SUBMITTED SPEC SHEETS FOR THE MODEL 496 ARE
 ILLEGIBLE. SUBMIT NEW SHEETS. WPB AMEND. TO FBC SEC.
 107.2.1.
 8) THE SUBMITTED SPECICIFICATION (PAGES 8,10) FOR THE
 EXCELA-FLO MEGR-1100 & 1200 SERIES REGULATOR IS
 ILLEGIBLE. SUBMIT A CLEAR SHEET FOR REVIEW. WPB AMEND.
 TO FBC SEC. 107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-28 Cont ID  
Sent By lcrespo Date 2021-07-28 Time 16:33 Rev Time 0.00
Received By lcrespo Date 2021-07-23 Time 11:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-08 Cont ID  
Sent By rmcdouga Date 2021-07-08 Time 17:58 Rev Time 0.00
Received By rmcdouga Date 2021-06-14 Time 13:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2021-07-27 Cont ID  
Sent By abelisle Date 2021-07-27 Time 12:07 Rev Time 0.00
Received By abelisle Date 2021-07-27 Time 12:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-06-21 Cont ID  
Sent By tklarge Date 2021-06-21 Time 08:55 Rev Time 0.00
Received By tklarge Date 2021-06-21 Time 08:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-16 Cont ID  
Sent By cthroop Date 2021-06-16 Time 06:22 Rev Time 0.00
Received By cthroop Date 2021-06-16 Time 06:19 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-07-06 Cont ID  
Sent By rthermid Date 2021-07-06 Time   Rev Time  
Received By rthermid Date 2021-07-06 Time   Sent To I
Notes
***NONE***