Plan Review Stops For Permit 21030387 |
Review Stop |
AD |
ADDRESSING |
Rev No |
4 |
Status |
P |
Date |
2021-04-19 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-04-19 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-04-19 |
Time |
09:48 |
Sent To |
|
|
Notes |
2021-04-19 09:49:06 | SCOPE OF WORK FOR BOTH BUILDINGS 3709 S OLIVE AVE AND | | 301 CENTRAL DR |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
F |
Date |
2021-04-15 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-04-15 |
Time |
17:16 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-04-15 |
Time |
17:16 |
Sent To |
|
|
Notes |
2021-04-15 17:16:46 | COMMENTS NOT FROM 3.25.21 OR 4.6.21: TWO BUILDINGS ON | | PROPERTY, WILL THE WORK BE FOR THE EAST OR WEST BLDG? | | WEST BLDGING HAS A HALF ADDRESS, PLEASE HAVE OWNER | | CONTACT [email protected] TO DISCUSS READDRESSING THE NO | | LONGER ALLOWED HALF ADDRESS. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2021-04-06 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-04-06 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-04-06 |
Time |
12:50 |
Sent To |
|
|
Notes |
2021-04-06 12:51:29 | COMMENTS NOT ADDRESSED: TWO BUILDINGS ON PROPERTY, WILL | | THE WORK BE FOR THE EAST OR WEST BLDG? WEST BLDGING HAS | | A HALF ADDRESS, PLEASE HAVE OWNER CONTACT | | [email protected] TO DISCUSS READDRESSING THE NO LONGER | | ALLOWED HALF ADDRESS. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-03-25 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-03-25 |
Time |
16:04 |
Sent To |
|
|
Notes |
2021-03-25 16:05:40 | TWO BUILDINGS ON PROPERTY, WILL THE WORK BE FOR THE | | EAST OR WEST BLDG? WEST BLDGING HAS A HALF ADDRESS, | | PLEASE HAVE OWNER CONTACT CPUELLWWPB.ORG TO DISCUSS | | READDRESSING THE NO LONGER ALLOWED HALF ADDRESS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2021-05-04 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-05-04 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-05-04 |
Time |
14:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2021-04-22 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-04-22 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-04-22 |
Time |
10:50 |
Sent To |
|
|
Notes |
2021-04-22 10:56:53 | CODES IN EFFECT | | | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | 7TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | 1) SERVICE CONDUCTORS ARE UNDERSIZED AS PER THE LOAD | | CALCULATIONS SUBMITTED. PLEASE PROVIDE ADEQUATE | | CONDUCTORS. NEC 230.23. PLEASE NOTICE THAT THE AMPACITY | | OF THE SERVICE CONDUCTORS CANNOT BE DERATED IN THIS | | CASE. NEC 310.15(7). | | DEMAND LOAD INDICATED IS 131 AMPS (BUILD 1) + 96 AMPS | | (BUILD 2) = 227 AMPS. MINIMUM SIZE FOR SERVICE | | CONDUCTORS IS 4/0 CU (SERVICE CONDUCTORS CANNOT BE | | DERATED NEC 310.15(7)) | | | | CORRECTED | | | | 2) PLEASE SHOW LOCATION OF SERVICE METERS, DISCONNECTS, | | AND NEW PANELS. | | | | NOT CORRECTED. PLEASE PROVIDE LOCATIONS OF METERS, | | DISCONNECTS AND PANELS | | | | 2) PLEASE SPECIFY SIZE OF BREAKER FOR MAIN DISCONNECT A | | (150 AMPS). IF NOT USING A BREAKER PLEASE SPECIFY HOW | | FEEDER FROM DISCONNECT A TO NEW PANEL BUILD IS | | PROTECTED (TAP RULES?) | | | | NOT CORRECTED. WE CANNOT DETERMINE HOW THE FEEDER FROM | | DISCONNECT A TO PANEL BUILD 1 IS PROTECTED. WHAT IS THE | | DISTANCE FROM DISCONNECT A TO THE PANEL? DOES THE | | DISCONNECT HAS AN INTEGRATED BREAKER? | | | | 3) PLEASE INDICATE SHORT CIRCUIT INTERRUPTING CAPACITY | | FOR DISCONNECTS AND PANEL BOARDS. FBC 107 | | | | NOT CORRECTED | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | THE RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR | | MS | | | | ENRIQUE QUINONEZ P.E. | | ELECTRICAL PLANS EXAMINER | | DEVELOPMENT SERVICES | | CITY OF WEST PAM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6746. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2021-04-07 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-04-07 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-04-07 |
Time |
09:25 |
Sent To |
|
|
Notes |
2021-04-07 09:51:36 | CODES IN EFFECT | | | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | 7TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | 1) SERVICE CONDUCTORS ARE UNDERSIZED AS PER THE LOAD | | CALCULATIONS SUBMITTED. PLEASE PROVIDE ADEQUATE | | CONDUCTORS. NEC 230.23. PLEASE NOTICE THAT THE AMPACITY | | OF THE SERVICE CONDUCTORS CANNOT BE DERATED IN THIS | | CASE. NEC 310.15(7). | | DEMAND LOAD INDICATED IS 131 AMPS (BUILD 1) + 96 AMPS | | (BUILD 2) = 227 AMPS. MINIMUM SIZE FOR SERVICE | | CONDUCTORS IS 4/0 CU (SERVICE CONDUCTORS CANNOT BE | | DERATED NEC 310.15(7)) | | | | 2) PLEASE SHOW LOCATION OF SERVICE METERS, DISCONNECTS, | | AND NEW PANELS. | | | | 2) PLEASE SPECIFY SIZE OF BREAKER FOR MAIN DISCONNECT A | | (150 AMPS). IF NOT USING A BREAKER PLEASE SPECIFY HOW | | FEEDER FROM DISCONNECT A TO NEW PANEL BUILD IS | | PROTECTED (TAP RULES?) | | | | 3) PLEASE INDICATE SHORT CIRCUIT INTERRUPTING CAPACITY | | FOR DISCONNECTS AND PANEL BOARDS. FBC 107 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | THE RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR | | MS | | | | ENRIQUE QUINONEZ P.E. | | ELECTRICAL PLANS EXAMINER | | DEVELOPMENT SERVICES | | CITY OF WEST PAM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6746. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-03-25 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-03-25 |
Time |
15:40 |
Sent To |
|
|
Notes |
2021-03-25 15:41:05 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | 7TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | 1) SERVICE CONDUCTORS ARE UNDERSIZED AS PER THE LOAD | | CALCULATIONS SUBMITTED. PLEASE PROVIDE ADEQUATE | | CONDUCTORS. NEC 230.23. PLEASE NOTICE THAT THE AMPACITY | | OF THE SERVICE CONDUCTORS CANNOT BE DERATED IN THIS | | CASE. NEC 310.15(7). | | 2) DOES THE 150 AMPS DISCONNECT FOR BUILD 2 HAS A | | CIRCUIT BREAKER? IF YES, PLEASE INDICATE BREAKER SIZE | | CON RISER DIAGRAM. | | 3) PLEASE INDICATE SHORT CIRCUIT INTERRUPTING CAPACITY | | FOR DISCONNECTS AND PANEL BOARDS. FBC 107 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR | | MS | | | | ENRIQUE QUINONEZ P.E. | | ELECTRICAL PLANS EXAMINER | | DEVELOPMENT SERVICES | | CITY OF WEST PAM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6746. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-05-04 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-05-04 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-04-27 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-04-22 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-04-22 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-04-14 |
Time |
11:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-04-07 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-04-07 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-04-01 |
Time |
12:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-03-25 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-03-25 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-03-10 |
Time |
11:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-03-25 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-03-25 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-03-25 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|