Plan Review Details - Permit 21021299
Plan Review Stops For Permit 21021299 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2021-03-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-03-24 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-03-24 |
Time |
10:06 |
Sent To |
|
|
Notes |
2021-03-24 10:13:56 | THE GENERATOR IS LOCATED IN AN "AE" FLOOD ZONE AND IS | | REQUIRED TO BE LOCATED AT OR ABOVE THE FINISH FLOOR | | ELEVATION OF THE LIVING SPACE OF THE HOUSE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-05-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-05-12 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-05-12 |
Time |
10:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-03-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-03-30 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-03-30 |
Time |
16:08 |
Sent To |
|
|
Notes |
2021-03-30 16:18:07 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | SUBFEEDER TO BE 3/0 COPPER FOR 200A SUBFEEDER. | | | | 310.15(B)(7)(2) FOR A FEEDER RATED 100 THROUGH 400 | | AMPERES, THE FEEDER CONDUCTORS SUPPLYING THE ENTIRE | | LOAD ASSOCIATED WITH A ONE-FAMILY DWELLING, OR THE | | FEEDER CONDUCTORS SUPPLYING THE ENTIRE LOAD ASSOCIATED | | WITH AN INDIVIDUAL DWELLING UNIT IN A TWO-FAMILY OR | | MULTIFAMILY DWELLING, SHALL BE PERMITTED TO HAVE AN | | AMPACITY NOT LESS THAN 83 PERCENT OF THE FEEDER RATING. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2021-04-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-07 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-07 |
Time |
15:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-04-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-15 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-03-19 |
Time |
16:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2021-04-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-07 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-07 |
Time |
15:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-03-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-03-24 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-03-24 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-05-20 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2021-05-20 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2021-05-20 |
Time |
|
Sent To |
|
|
Notes |
2021-04-14 13:45:24 | ****************************ZONING | | REVIEW************************************* | | | | PROVIDE THE SIDE AND REAR SETBACKS FOR THE GENERATOR. | | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR | | FEET INTO A SETBACK. | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISON | | 561-822-1449 | | [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |