Plan Review Stops For Permit 21020712 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-05-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-10 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-10 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-03-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-03-22 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-03-22 |
Time |
10:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-03-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-03-11 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-03-11 |
Time |
07:35 |
Sent To |
|
|
Notes |
2021-03-11 07:50:29 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE VALUATION OF $2450.00 IS LOW FOR THIS SIGN. | | BASED ON MARSHALL & SWIFT THE VALUE FOR PERMITTING | | PURPOSES IS $6655.00. FBC AMENDMENTS 109.3 BUILDING | | PERMIT VALUATION. FOR PERMITTING PURPOSES, VALUATION OF | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE | | CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET | | BY THE BUILDING OFFICIAL. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-05-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-05-10 |
Time |
07:04 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-05-10 |
Time |
06:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-02-23 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-02-23 |
Time |
20:36 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-02-23 |
Time |
19:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-05-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-05-10 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-05-03 |
Time |
07:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-04-28 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-28 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-09 |
Time |
09:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-03-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-03-16 |
Time |
07:26 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-02-16 |
Time |
14:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-05-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-05-10 |
Time |
07:05 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-05-10 |
Time |
07:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-04-28 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-28 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-28 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-02-18 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2021-02-18 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2021-02-18 |
Time |
16:37 |
Sent To |
|
|
Notes |
2021-02-18 16:37:44 | HARD COPY WAS PROVIDED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2021-05-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2021-05-05 |
Time |
10:54 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2021-05-04 |
Time |
13:41 |
Sent To |
|
|
Notes |
2021-05-05 10:57:20 | PERMITTED: 32.75 SF | | PROPOSED: 22.39 SF | | | | SIGN GRANTED WAIVER II TO EXCEED 40% OF THE STOREFRONT | | LENGTH. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-04-26 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2021-04-26 |
Time |
18:03 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2021-04-26 |
Time |
17:25 |
Sent To |
|
|
Notes |
2021-04-26 18:03:54 | FAILED | | | | 1ST FLOOR FASCIA IDENTITY SIGN | | | | 1) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE | | THAT REVERSE CHANNEL LETTERS ARE FABRICATED OUT OF | | ALUMINUM WITH A MINIMUM METAL THICKNESS OF .060 INCHES. | | WHILE THIS IS NOTED ON SHEET A1, IT IS NOT UPDATED ON | | SHEET A3, WHICH IS SIGNED BY THE ENGINEER. SHEET A3 | | STILL SHOWS THE ALUMINUM RETURNS AS ONLY HAVING A | | THICKNESS OF .050 INCHES. | | | | 2) PROVIDE HOW THE SHIELDED LED CABLE CONDUITS TO THE | | REMOTE LED DRIVER ASSEMBLY LOCATED INSIDE THE STORE | | WILL BE CONCEALED AND NOT VISIBLE TO THE PUBLIC AS THEY | | CROSS THE ARCADE AS REQUIRED BY THE ROSEMARY SQUARE | | TENANT SIGN CRITERIA. THIS INCLUDES ANY BELL BOX, J BOX | | OR OTHER ELECTRICAL CONNECTION. IF THE CONDUIT, ETC. IS | | IN THE ARCADE CEILING YOU MAY PROVIDE THIS INFORMATION | | AS A NOTE ON THE PLANS. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-03-15 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2021-03-15 |
Time |
15:33 |
Rev Time |
0.75 |
Received By |
eschneid |
Date |
2021-03-15 |
Time |
15:33 |
Sent To |
|
|
Notes |
2021-03-15 15:36:59 | FAILED | | | | 1ST FLOOR FASCIA IDENTITY SIGN | | | | PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | 1) THE ROSEMARY SQUARE TENANT SIGN CRITERIA MEASURES | | SIGNAGE ALLOWANCE AS FOLLOWS - ONE SQUARE FOOT OF | | SIGNAGE FOR EACH ONE LINEAR FOOT OF STORE FRONTAGE. | | SINCE THIS SIGN IS ON THE 1ST FLOOR, THE SIZE OF THE | | SIGN IS BASED ON THE 1ST FLOOR FRONTAGE. PROVIDE THE | | LINEAR FEET OF 1ST FLOOR STORE FRONTAGE (APPEARS TO BE | | APPROXIMATELY 30 FEET) SO THAT STAFF CAN VERIFY HOW | | MUCH SIGN SQUARE FOOTAGE IS PERMITTED. BASED ON A 30 | | FOOT FRONTAGE, THE FASCIA IDENTITY SIGN AT 22.39 SQUARE | | FEET IS PERMITTED. | | | | 2) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A | | FASCIA IDENTITY SIGN TO HAVE A MAXIMUM WIDTH OF 40 | | PERCENT OF THE STOREFRONT FRONTAGE. ONCE THE 1ST FLOOR | | STORE FRONTAGE DIMENSION IS PROVIDED, THEN STAFF CAN | | VERIFY IF THE PROPOSED 1ST FLOOR FASCIA IDENTITY SIGN | | MEETS THIS STANDARD. HOWEVER, BASED ON THE SITE PLAN, | | IT APPEARS THAT THE 1ST FLOOR FRONTAGE IS APPROXIMATELY | | 30 FEET, WHICH WOULD ONLY PERMIT A SIGN DIMENSION OF 12 | | FEET BY RIGHT. THE PROPOSED 14 FOOT 4.5 INCH LONG SIGN | | EXCEEDS THE 40 PERCENT ALLOWANCE. THE SIGN WIDTH | | DIMENSION MAY BE INCREASED BY 25 PERCENT WITH THE | | APPROVAL OF A WAIVER II, WHICH WOULD PERMIT A SIGN UP | | TO 15 FEET IN LENGTH. A WAIVER II REQUIRES THE | | SUBMITTAL OF A MINOR PLANNED DEVELOPMENT AMENDMENT TO | | THE CITY'S PLANNING DIVISION AND ITS SUBSEQUENT | | APPROVAL. NOTE: EXACT DIMENSIONS WILL BE BASED ON THE | | ACTUAL 1ST FLOOR FRONTAGE THAT HAS NOT YET BEEN | | PROVIDED. | | | | 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE | | THAT REVERSE CHANNEL LETTERS ARE FABRICATED OUT OF | | ALUMINUM WITH A MINIMUM METAL THICKNESS OF .060 INCHES. | | THE SIGN DETAIL SHOWS THE ALUMINUM RETURNS AS ONLY | | HAVING A THICKNESS OF .050 INCHES. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | |
|
|