Plan Review Stops For Permit 21020498 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-06-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-17 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-06-17 |
Time |
17:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-03-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-03-11 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-03-11 |
Time |
13:59 |
Sent To |
|
|
Notes |
2021-03-11 14:01:13 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) PLEASE REVISE NOTES ON THE SURVEY. THE GENERATOR | | EXHAUST SHALL BE LOCATED 10 FEET FROM ANY OPENINGS INTO | | A BUILDING. FBC-R303.5.1 INTAKE OPENINGS. MECHANICAL | | AND GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE | | LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM ANY | | HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | AND LOADING DOCKS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-06-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-17 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-06-17 |
Time |
17:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-03-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-03-15 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-03-15 |
Time |
15:38 |
Sent To |
|
|
Notes |
2021-03-15 15:54:39 | PLAN REVIEW GENERATOR / ELECTRICAL | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) PROVIDE SPECIFICATIONS FOR AUTOMATIC TRANSFER | | SWITCH. ATS | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2021-06-15 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-06-15 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-06-15 |
Time |
09:31 |
Sent To |
|
|
Notes |
2021-06-15 09:31:25 | GAS APPLIED FOR SEPARATELY |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-04-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-05 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-05 |
Time |
12:25 |
Sent To |
|
|
Notes |
2021-04-05 13:40:33 | 1ST REVIEW FBC-2020 RES. | | PERMIT- 21020498 | | 4/5/2021 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE A COMPLETE GAS RISER DRAWING THAT INCLUDES | | BOTH THE NEW AND EXISTING GAS PIPING AND APPLIANCES AT | | THE RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. REFER | | TO FBC RES. CHAPTER 24 FUEL GAS. | | | | 2) PLEASE CORRECT THE 864,000 BTU GENERATOR LOAD TO | | 756,000 AS LISTED IN THE SUBMITTED GENERATOR SPECS- | | SECTION 107.2.1 WPB. | | | | 3) SURVEY: PLEASE CORRECT THE 5' GENERATOR DISTANCE | | FROM OPENINGS TO 10' IN COMPLIANCE WITH R305.1 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-06-22 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-06-22 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-06-15 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-04-05 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2021-04-05 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2021-03-10 |
Time |
18:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2021-04-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-05 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-05 |
Time |
12:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-06-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-17 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-06-17 |
Time |
17:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-03-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-03-11 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-03-11 |
Time |
13:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-06-21 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-06-21 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-03-24 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-03-24 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2021-03-24 |
Time |
|
Sent To |
I |
|
Notes |
2021-03-24 11:31:45 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 3/24/2021 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. ADDRESS BUILDING/STRUCTURAL COMMENTS. PER THE | | FLORIDA BUILDING CODE, MECHANICAL EQUIPMENT MUST BE | | SETBACK A MINIMUM OF 10 FEET FROM ANY DOOR WINDOWS AND | | OPENINGS. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | TTY: 800.955.8771 | | E: [email protected] | | W: WPB.ORG | | |
|
|