Plan Review Details - Permit 21020437
Plan Review Stops For Permit 21020437
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-04-12 Cont ID  
Sent By jwitmer Date 2021-04-12 Time 16:19 Rev Time 0.00
Received By jwitmer Date 2021-04-12 Time 16:15 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time 12:57 Rev Time 0.00
Received By jwitmer Date 2021-02-17 Time 11:30 Sent To  
Notes
2021-02-17 11:45:43TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-04-26 Cont ID  
Sent By jwitmer Date 2021-04-26 Time 09:13 Rev Time 0.00
Received By jwitmer Date 2021-04-26 Time 08:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-04-12 Cont ID  
Sent By jwitmer Date 2021-04-12 Time 16:44 Rev Time 0.00
Received By jwitmer Date 2021-04-12 Time 16:15 Sent To  
Notes
2021-04-12 16:40:13WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21020437
 ADD: 1900 CONSULATE PL. SUITE: 2202
 CONT: BUILD & FIX INC.
 TEL: 561-908-3212
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MONDAY APRIL 12TH/ 2021
 ACTION: DENIED
  
 1) EXISTING & PROPOSED FLOOR PLAN:
 1) COMPLIED.
  
 2) 2ND REQUEST. NOTE 19 INDICATES THE REMOVAL AND
 REPLACEMENT OF ALL FLOORS. SUBMITTED THIS REVIEW IS A
 SALES BROCHURE FOR ECO-ULTRA QUIET UNDERLAYMENT FOR USE
 WITH LAMINATE, ENGINEERED, BAMBOO AND SOLID FLOORING.
 THIS IS NOT REQUIRED TEST REPORTS. YOU WILL NEED TO
 SUBMIT SEPARATE TEST REPORTS FOR THE LAMINATE FLOORING
 (3) AND F (3) FOR THE PORCELAIN TILE, FOR 6 INCH SLAB
 NO DROP CEILING. STATING THE CODE IS NOT ENOUGH, THE
 CONTRACTOR OR DESIGNER OF RECORD MUST SUBMIT THE ACTUAL
 TEST REPORTS. THERE ARE A LOT OF PRODUCTS THAT CAN BE
 USED IN A SINGLE FAMILY HOUSE BUT NOT IN A CONDOMINIUM.
 1ST ROUND OF COMMENTS. TYPE OF FLOOR FINISH NOT GIVEN.
 FLOOR INSULATION (FBC-B 2020) FOR TILE, STONE, MARBLE,
 VINYL AND WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND
 UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING
 STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH
 OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/
 NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 2A) 2ND REQUEST. FBC-B 2020 1207.3 STRUCTURE-BORNE
 SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS
 OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) 2ND REQUEST. FBC-B 2020 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) 2ND REQUEST. FLAME SPREAD- FBC-B 2020 603.1.
 EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED
 FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE
 SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT
 MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-02-17 Cont ID  
Sent By jwitmer Date 2021-02-17 Time 12:57 Rev Time 0.00
Received By jwitmer Date 2021-02-17 Time 11:31 Sent To  
Notes
2021-02-17 12:51:06WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21020437
 ADD: 1900 CONSULATE PL. SUITE: 2202
 CONT: BUILD & FIX INC.
 TEL: 561-908-3212
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. FEB. 17TH/ 2021
 ACTION: DENIED
  
 1) EXISTING & PROPOSED FLOOR PLAN:
 1A) GYPSUM BOARD PARTITIONS & CEILINGS. THIS WHOLE
 HEADING REFERS MOSTLY TO R-3 CONSTRUCTION. WITH 2 X4
 STUD WALLS, CEILINGS FASTENED TO BOTTOM CHORD OF WOOD
 TRUSSES. PLEASE REFER TO THE 2020 FBC-B SECTION 603.1.1
 WHERE FIRE RETARDANT TREATED WOOD CAN BE INSTALLED.
  
 1B) DESIGN PARAMETERS REFERS TO ASCE-7-10. THIS WAS THE
 VERSION OF THE ASCE-7 UNDER THE 2017 FBC-B. UNDER THE
 2020 FBC-B THE ASCE 7 VERSION IS ASCE 7-16. PLEASE
 UPDATE CHAPTER 35 OF THE 2020 FBC-B.
  
 1C) THERE ARE DESIGN PARAMETER NOTES THAT DO NOT
 PERTAIN TO THIS PROJECT, TOP CHORD, BOTTOM CHORD LOADS,
 SOIL BEARING CAPACITY, PLEASE REMOVE. 2020 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATION 107.2.1. W.P.B. ADMINISTRATIVE
 CODE/2017 DRAWINGS & SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO
 THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES.
  
 1D) DESIGN PARAMETERS, THE MEAN ROOF HEIGHT IS GIVEN AT
 30 FEET, THEN AGAIN, THE PLANS STATE THE NUMBER OF
 STORIES AS 12 STORIES. PLEASE NOTE THIS IS A 22 STORY
 HIGHRISE BUILDING. UPDATE PLANS. 107.2.1.2 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 1E) THE DESIGN PARAMETERS LIST THE CONSTRUCTION TYPE AS
 IIB. PLEASE REFER TO TABLE 504.4 ALLOWABLE NUMBER OF
 STORIES ABOVE GRADE. FOR A 22-STORY BUILDING R-2
 OCCUPANCY THE MINIMUM BUILDING TYPE IS I-A.
  
 1F) CODE REQUIREMENTS ALSO LIST TYPE OF CONSTRUCTION
 CHAPTER 6 TYPE II-B SPRINKLERED. . PLEASE REFER TO
 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE.
 FOR A 22-STORY BUILDING R-2 OCCUPANCY THE MINIMUM
 BUILDING TYPE IS I-A.
  
 SCOPE OF WORK:
  
 1G) NOTE 5, 6 & 15 ALL DEAL WITH THE EITHER RAISING OR
 DROPPING THE CEILINGS IN THE ENTRANCE, BATHROOMS AND
 KITCHEN AREAS.
 AS THE DESIGNER OF RECORD PLEASE PROVIDE THE TYPE OF
 MATERIALS FOR THE FRAMING MEMBERS OF THE DROPPED
 CEILINGS, SPAN, SIZE OF THE METAL STUDS, WILL THERE BE
 MIDSPAN SUPPORTS AND THICKNESS OF DRYWALL FINISH.
  
 1H)(1) NOTE 18 INDICATES THE INSTALLATION OF A NEW
 GLASS DOOR. PLEASE PROVIDE THE LOCATION. IF THIS DOOR
 IS AN EXTERIOR DOOR PLEASE ALSO PROVIDE THE PRODUCT
 APPROVAL FOR THE DOOR. 2020 FBC-B 1609.1.2 PROTECTION
 OF OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE
 CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS
  
 1H)(2) PLEASE IDENTIFY ON THE PRODUCT APPROVAL BEFORE
 SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION
 TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH
 GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT,
 TYPE OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED
 OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 2) NOTE 19 INDICATES THE REMOVAL AND REPLACEMENT OF ALL
 FLOORS. TYPE OF FLOOR FINISH NOT GIVEN. FLOOR
 INSULATION (FBC-B 2020) FOR TILE, STONE, MARBLE, VINYL
 AND WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND
 UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING
 STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH
 OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/
 NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 2A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 2C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 LVT & LPT LUXURY VINYL TILE. FLOOR FINISH
 CLASSIFICATION AS REQUIRED IN SECTION 804.2
 CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF
 THE 2017 FBC-B.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-04-14 Cont ID  
Sent By fgiaquin Date 2021-04-14 Time 21:06 Rev Time 0.00
Received By fgiaquin Date 2021-04-14 Time 20:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-02-16 Cont ID  
Sent By fgiaquin Date 2021-02-16 Time 22:48 Rev Time 0.00
Received By fgiaquin Date 2021-02-16 Time 21:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-04-22 Cont ID  
Sent By pleduc Date 2021-04-22 Time   Rev Time 0.00
Received By pleduc Date 2021-04-22 Time 10:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-04-09 Cont ID  
Sent By pleduc Date 2021-04-09 Time   Rev Time 0.00
Received By pleduc Date 2021-04-09 Time 11:49 Sent To  
Notes
2021-04-09 11:50:04THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS.
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD, INCLUDING DEMO.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE DEPARTMENT

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-02-12 Cont ID  
Sent By pleduc Date 2021-02-12 Time   Rev Time 0.00
Received By pleduc Date 2021-02-10 Time 16:26 Sent To  
Notes
2021-02-12 14:14:57THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS.
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD, INCLUDING DEMO.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE DEPARTMENT
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2021-04-28 Time   Rev Time 0.00
Received By aoliver Date 2021-04-21 Time 08:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-04-20 Time   Rev Time 0.00
Received By aoliver Date 2021-04-08 Time 17:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-03-09 Cont ID  
Sent By shill Date 2021-03-09 Time 11:30 Rev Time 0.00
Received By shill Date 2021-02-09 Time 12:30 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2021-02-17 Cont ID  
Sent By jwitmer Date 2021-02-17 Time 11:44 Rev Time 0.00
Received By jwitmer Date 2021-02-17 Time 11:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2021-02-22 Cont ID  
Sent By medwards Date 2021-02-22 Time 15:12 Rev Time 0.00
Received By medwards Date 2021-02-22 Time 15:05 Sent To  
Notes
2021-02-22 15:13:48NO MECHANICAL WORK SUBMITTED UNDER THIS PROJECT.ME

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-04-28 Cont ID  
Sent By ccole Date 2021-04-28 Time 15:13 Rev Time 0.00
Received By ccole Date 2021-04-28 Time 15:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-04-20 Cont ID  
Sent By ccole Date 2021-04-20 Time 09:14 Rev Time 0.00
Received By ccole Date 2021-04-20 Time 08:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-02-24 Cont ID  
Sent By ccole Date 2021-02-24 Time 16:31 Rev Time 0.00
Received By ccole Date 2021-02-24 Time 15:32 Sent To  
Notes
2021-02-24 16:31:151ST REVIEW FBC-2020 PLUMBING
 PERMIT-21020437
 2/24/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) A2.0: PROVIDE A WATER RISER AND A FLAT LINE DRAWING
 SHOWING HOW WATER WILL BE SUPPLIED TO THE ISLAND SINK,
 DISHWASHER, AND REFRIGERATOR ICE MAKER - SECTION
 103.5.1.3 WPB. SHGOW LOCATIONS OF WARTER HAMMER
 ARRESTORS AND BACKFLOW PREVENTERS- SECTION 604.9 &
 608.3 FBC P.
  
 2) A2.0: SHOW THE SHUTOFF VALVES FOR THE WASHING
 MACHINE WILL BE RELOCATED TO A LOCATION WITH ACCESS-
 SECTION 606.3 FBC P.
  
 3) A2.0: REFER TO SECTION 1002.1 FBC P- THE HORIZONTAL
 DISTANCE FROM THE CENTERLINE OF THE NEW TUB DRAIN
 OUTLET TO THE CENTERLINE OF THE INLET OF THE EXISTING
 TRAP SHALL NOT EXCEED 30". PLEASE PLACE A NOTE ON THE
 PLAN INDICATING COMPLIANCE.
  
 4) A2.0: NEW DRAIN PIPE PENETRATIONS OF THE EXISTING
 SLAB WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR
 SPACE AROUND THE PIPING. PROVIDE A UL TESTED AND
 APPROVED FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN-
 SECTION 315.1 FBC P, AND SECTION 714.4.1.2 FBC B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-04-21 Cont ID  
Sent By medwards Date 2021-04-21 Time 09:23 Rev Time 0.00
Received By medwards Date 2021-04-21 Time 09:22 Sent To  
Notes
2021-04-21 09:23:58ORIGINAL SIGNED AND SEALED PAPER DRAWING ROUTED TO
 STORAGE. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-04-09 Cont ID  
Sent By equinone Date 2021-04-09 Time 10:31 Rev Time 0.00
Received By equinone Date 2021-04-09 Time 10:31 Sent To  
Notes
2021-04-09 10:32:06ORIGINAL PAPER DRAWINGS WITH SIGNATURE AND SEAL. ROUTED
 TO STORAGE. EQ

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-02-09 Cont ID  
Sent By equinone Date 2021-02-09 Time 16:55 Rev Time 0.00
Received By equinone Date 2021-02-09 Time 16:55 Sent To  
Notes
2021-02-09 16:55:55ORIGINAL PAPER DRAWINGS WITH SIGNATURE AND SEAL. ROUTED
 TO STORAGE. EQ

Review Stop Z ZONING
Rev No 1 Status N Date 2021-03-08 Cont ID  
Sent By kalexand Date 2021-03-08 Time 22:54 Rev Time 0.00
Received By kalexand Date 2021-03-08 Time 22:54 Sent To I
Notes
2021-03-08 22:55:39INTERIOR WORK- ZONING NOT REQUIRED