Plan Review Details - Permit 21010857
Plan Review Stops For Permit 21010857
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2021-02-02 Cont ID  
Sent By jwitmer Date 2021-02-02 Time 10:45 Rev Time 0.00
Received By jwitmer Date 2021-02-02 Time 10:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-03-16 Cont ID  
Sent By jwitmer Date 2021-03-16 Time 09:09 Rev Time 0.00
Received By jwitmer Date 2021-03-16 Time 08:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2021-02-02 Time 11:59 Rev Time 0.00
Received By jwitmer Date 2021-02-02 Time 10:32 Sent To  
Notes
2021-02-02 11:45:56WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21010857
 ADD: 1801 S. FLAGLER DR. SUITE: 1010
 CONT: PHILIP E. JOHNSON INC.
 TEL: 561-262-1795
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. FEB. 02/2021
 ACTION: DENIED
  
 1) THE COVER SHEET:
 1A) UNDER THE HEADING OF PROJECT NAME AND ADDRESS YOU
 HAVE THE JOB LOCATED IN DELRAY BEACH, PLEASE UPDATE
 PLAN TO THE CITY OF WEST PALM BEACH, FL. ADMINISTRATION
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED.
  
 1B) UNDER THE HEADING USE AND OCCUPANCY THE OCCUPANCY
 DECLARED IS A R-3 OCCUPANCY FOR SINGLE FAMILY HOMES.
 PLEASE UPDATE THE PLAN TO THE OCCUPANCY TYPE R-2
 SECTION 310.4 OF THE 2020 FBC-B. APARTMENT HOUSES,
 CONDOMINIUMS, ETC.
  
 1C) UNDER THE HEADING USE AND OCCUPANCY & TYPE OF
 CONSTRUCTION THE OCCUPANCY DECLARED THE CONSTRUCTION
 TYPE AS TYPE II-B. PLEASE REVIEW IN THE 2020 FBC-B
 TABLE 504.4 FOR ALLOWABLE STORIES. THIS IS AN 18-STORY
 BUILDING, THE ONLY CONSTRUCTION TYPE THAT ALLOWS AN 18
 STORY BUILDING IS TYPE I-A CONSTRUCTION.
  
 2) SHEET A-002 THE DEMO PLAN IN NEITHER THE MASTER BATH
 NOR THE GUEST BATH ARE SHOWN EXISTING SHOWERS OR TUBS.
 THE MATER BATH LOOKS LIKE THERE ARE 2 CLOSETS WITHIN
 THE MASTER BATH, ADDITIONAL INFORMATION IS REQUIRED.
 107.2.1.2.
  
 3) SHEET A-201 THE FLOOR PLAN SHOWS IN THE MASTER BATH
 A NEW SHOWER AND TUB LOCATION. THE SUBMITTED PLANS DO
 HAVE FIRE ASSEMBLY FOR THROUGH PENETRATIONS OF FIRE
 RATED FLOORS BUT THERE IS NO INFORMATION AS TO THE
 CORING OF THE CONCRETE FLOOR FOR THE NEW THROUGH
 PENETRATION. THESE SLABS ARE POST TENSION SLABS, HOW
 ARE YOU GOING TO KEEP FROM CORING THROUGH A POST
 TENSIONED CHORD. 107.2.1.2. ADDITIONAL INFORMATION IS
 REQUIRED.
  
 4) SHEET A-201 DOES PROVIDE A LEGEND FOR THE TILE
 BACKER BOARD FOR THE SHOWERS BUT THERE IS NO
 INFORMATION AS TO THE HEIGHT OF THE TILE IN THE SHOWER
 AND OR BATHTUB AREAS. 2020 FBC-B SHOWERS & TUBS 1210.3.
 SHOWER COMPARTMENTS AND BATHTUBS WITH INSTALLED SHOWER
 HEADS SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO
 A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET.
  
 5) THE FLOOR PLAN INDICATES NEW FLOOR FINISHES WITH
 NOTE # 9. THERE IS NO NOTE # 9 IN THE MASTER BATH OR
 BATH # 2 AS IF THE FLOORS ARE TO BE REPLACED. PLEASE
 PROVIDE A SQUARE FOOT AREA FOR THE FLOORS BEING
 REPLACED. 107.2.1.2. ADDITIONAL INFORMATION, 109.3
 BUILDING PERMIT VALUATION.
  
 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-03-23 Cont ID  
Sent By fgiaquin Date 2021-03-23 Time 23:16 Rev Time 0.00
Received By fgiaquin Date 2021-03-23 Time 22:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-02-06 Cont ID  
Sent By fgiaquin Date 2021-02-06 Time 22:10 Rev Time 0.00
Received By fgiaquin Date 2021-02-06 Time 20:42 Sent To  
Notes
2021-02-06 22:10:02ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL DRAWING INCOMPLETE. NOTE: MORE PLAN
 REVIEW COMMENTS MAY OCCUR AFTER PLAN RESUBMITTAL. NO
 LIGHTING PLAN SUBMITTED. FBC 107.2.1
  
 2. NO SMOKE/CARBON ALARMS SHOWN PER FBC-RE 314&315
  
 3. RECEPTACLE SPACING INCORRECT FOR KITCHEN ISLAND.
 RANGE IN ISLAND HAS LESS THAN 12'' BEHIND IT AND IS
 CONSIDERED "SEPARATE SPACES" TO LEFT AND RIGHT.
 RECEPTACLES REQUIRED WITHIN 2' OF EACH SIDE OF COOKTOP
 ON ISLAND NEC 210.52
  
 4. SEVERAL RECEPTACLES SPACING VIOLATIONS THROUGHOUT
 CONDO, PROVIDE CORRECTIONS NEC 210.52
  
 5. PROVIDE ITEMIZED LOAD CALCULATION NOT A LOAD CALC
 STATING "ALL OTHER LOADS EXCLUDING AC". ALSO SERVICE
 FOR 1801 S FLAGLER IS 120/208 WYE 3-PHASE. 25.8 KVA
 LOAD WOULD BE 72AMPS NOT 107 AS SHOWN ON PLAN. PROVIDE
 ACCURATE LOAD CALC NEC 220.
  
 6. NO AFCI PROTECTION SHOWN PER NEC210.12A&B
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-03-12 Cont ID  
Sent By pleduc Date 2021-03-12 Time   Rev Time 0.00
Received By pleduc Date 2021-03-12 Time 13:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-01-27 Cont ID  
Sent By pleduc Date 2021-01-27 Time   Rev Time 0.00
Received By pleduc Date 2021-01-26 Time 11:09 Sent To  
Notes
2021-01-27 11:19:47THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1) SHEET A 201 - THERE ARE NO INDICATION OF SMOKE
 ALARMS OUTSIDE THE NEW CORRIDOR SPACE BY THE 2ND
 BATHROOM.
  
 PER NFPA 101, CH 31. EXISTING APARTMENT BUILDINGS
  
 31.3.4.5 SMOKE ALARMS.
 31.3.4.5.1* IN BUILDINGS OTHER THAN THOSE EQUIPPED
 THROUGHOUT WITH AN
 EXISTING, COMPLETE AUTOMATIC SMOKE DETECTION SYSTEM,
 SMOKE ALARMS
 SHALL BE INSTALLED IN ACCORDANCE WITH 9.6.2.10, AS
 MODIFIED BY 31.3.4.5.2,
 OUTSIDE EVERY SLEEPING AREA IN THE IMMEDIATE VICINITY
 OF THE BEDROOMS
 AND ON ALL LEVELS OF THE DWELLING UNIT, INCLUDING
 BASEMENTS.
  
 PLEASE REVIEW AND ENSURE THERE IS A SA IN THIS
 LOCATION.
  
  
 2) SHEET A 201 - THE ENTRY DOOR TO THE SPARE BEDROOM
 WAS MOVED. THERE ARE NO INDICATIONS OF A SMOKE ALARM
 WITHIN THIS ROOM AND ANY PREVIOUS LOCATION MAY HAV
 EBEEN AFEECTED BY THE DOOR LOCATION CHANGE..
  
 31.3.4.5.3 IN BUILDINGS OTHER THAN THOSE EQUIPPED
 THROUGHOUT WITH AN
 EXISTING, COMPLETE AUTOMATIC SMOKE DETECTION SYSTEM OR
 A COMPLETE,
 SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
 WITH 31.3.5,
 SMOKE ALARMS SHALL BE INSTALLED IN EVERY SLEEPING AREA
 IN
 ACCORDANCE WITH 9.6.2.10, AS MODIFIED BY 31.3.4.5.4.
 31.3.4.5.4 SMOKE ALARMS REQUIRED BY 31.3.4.5.3 SHALL BE
 PERMITTED TO BE
 BATTERY POWERED.
  
 PLEASE REVIEW AND ENSURE THERE IS A SA IN THIS
 LOCATION.
  
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-23 Cont ID  
Sent By fgiaquin Date 2021-03-23 Time 23:16 Rev Time 0.00
Received By fgiaquin Date 2021-03-11 Time 08:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-06 Cont ID  
Sent By fgiaquin Date 2021-02-06 Time 22:10 Rev Time 0.00
Received By fgiaquin Date 2021-01-25 Time 14:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2021-02-02 Cont ID  
Sent By medwards Date 2021-02-02 Time 14:27 Rev Time 0.00
Received By medwards Date 2021-02-02 Time 14:14 Sent To  
Notes
2021-02-02 14:27:56NO MECHANICAL WORK SHOWN ON PLANS. ME

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-03-19 Cont ID  
Sent By ccole Date 2021-03-19 Time 10:15 Rev Time 0.00
Received By ccole Date 2021-03-18 Time 16:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-02-05 Cont ID  
Sent By ccole Date 2021-02-05 Time 12:52 Rev Time 0.00
Received By ccole Date 2021-02-05 Time 12:52 Sent To  
Notes
2021-02-05 12:52:50NO 2ND REVIEW- SEE 1ST REVIEW COMMENTS.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-02-05 Cont ID  
Sent By ccole Date 2021-02-05 Time 12:42 Rev Time 0.00
Received By ccole Date 2021-02-05 Time 10:24 Sent To  
Notes
2021-02-05 13:05:341ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21010857
 2/5/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-201: PROVIDE A NOTE TO INDICATE A NEW SHOWER
 IS TO BE INSTALLED IN THE EXISTING COMMON BATH- SECTION
 107.2.1 WPB.
  
 2) A-201: PROVIDE SANITARY AND WATER RISER DRAWINGS AND
 LAYOUT PLANS FOR INSTALLATION OF THE NEW SHOWERS AND
 RELOCATED BATH AND KITCHEN SINKS- SECTION
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-03-16 Cont ID  
Sent By jwitmer Date 2021-03-16 Time 09:06 Rev Time 0.00
Received By jwitmer Date 2021-03-16 Time 08:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-02-02 Cont ID  
Sent By jwitmer Date 2021-02-02 Time 11:58 Rev Time 0.00
Received By jwitmer Date 2021-02-02 Time 11:48 Sent To  
Notes
***NONE***