Plan Review Details - Permit 21010841
Plan Review Stops For Permit 21010841
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-04-23 Cont ID  
Sent By rmcdouga Date 2021-04-23 Time 10:45 Rev Time 0.00
Received By rmcdouga Date 2021-04-23 Time 10:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-02-17 Cont ID  
Sent By rmcdouga Date 2021-02-17 Time 11:04 Rev Time 0.00
Received By rmcdouga Date 2021-02-17 Time 11:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-06-26 Cont ID  
Sent By jleahy Date 2021-06-26 Time 12:30 Rev Time 0.00
Received By jleahy Date 2021-06-26 Time 12:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2021-04-24 Cont ID  
Sent By jleahy Date 2021-04-24 Time 07:21 Rev Time 0.00
Received By jleahy Date 2021-04-24 Time 07:15 Sent To  
Notes
2021-04-24 07:25:35ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) VALUE OF POOL SEEMS LOW PLEASE SUBMIT A SIGNED
 CONTRACT FOR VALUE OF POOL.
  
 2) ELECTRICAL LOAD CALCULATION TO SHOW SERVICE IS LARGE
 ENOUGH TO HANDLE LOAD. 215.5
  
 3) CODE REFERENCED IS 2014 PLEASE SCHANGE TO 2017 NEC
 IN ELECTRICAL NOTE #1

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-02-04 Cont ID  
Sent By ppetty Date 2021-02-04 Time 10:32 Rev Time 0.00
Received By ppetty Date 2021-02-04 Time 10:02 Sent To  
Notes
2021-02-04 10:32:05CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SINCERELY,
  
 PHIL PETTY
 CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER
  
 561-805-6742
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-02-02 Cont ID  
Sent By fmittner Date 2021-02-02 Time 13:52 Rev Time 0.00
Received By fmittner Date 2021-02-02 Time 13:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2021-06-29 Time   Rev Time 0.00
Received By aoliver Date 2021-06-24 Time 14:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-24 Cont ID  
Sent By jleahy Date 2021-04-24 Time 07:29 Rev Time 0.00
Received By jleahy Date 2021-04-14 Time 16:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-17 Cont ID  
Sent By rmcdouga Date 2021-02-17 Time 11:04 Rev Time 0.00
Received By rmcdouga Date 2021-01-25 Time 08:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2021-06-29 Time   Rev Time 0.00
Received By   Date 2021-06-29 Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-04-21 Cont ID  
Sent By lcrespo Date 2021-04-21 Time 08:29 Rev Time 0.00
Received By lcrespo Date 2021-04-21 Time 08:24 Sent To  
Notes
2021-04-21 08:29:5904/21/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-01-26 Cont ID  
Sent By lcrespo Date 2021-01-26 Time 18:09 Rev Time 0.00
Received By lcrespo Date 2021-01-26 Time 18:09 Sent To  
Notes
2021-01-26 18:10:2001/26/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. A CONTAINMENT REDUCED PRINCIPAL ZONE BACKFLOW WILL
 BE REQUIRED AT THE WATER METER BY A LICENSED CONTRACTOR
 WITH A SEPARATE PERMIT. THE RPZ WILL NEED TO BE
 CERTIFIED BY THE CITY OF WEST PALM BEACH UTILITIES
 DEPARTMENT AND THE CROSS CONNECTION CONTROL MANUAL PAGE
 11 (C). THIS IS DUE TO THE AUTOFILL, WHICH WILL REQUIRE
 A BACKFLOW (PVB) FOR IT. THIS IS AN ISOLATION BACKFLOW,
 AND IT WILL BE REQUIRED TO BE CERTIFIED BY A LICENSED
 BACKFLOW CONTRACTOR. A REPORT MUST BE FILLED OUT AND BE
 WITH THE PERMIT AT FINAL AS THE INSPECTOR MUST TAKE FOR
 CITY RECORDS.
  
 2. SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE
 MAXIMUM SYSTEM FLOW. THE PUMP'S MAXIMUM FLOW FROM ITS
 PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN
 DETERMINING THE MAXIMUM SYSTEM FLOW RATE PER
 ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013
 EDITION ADDRESSES THE FLOW RATE IN GALLONS PER MINUTE
 (GPM). IT REQUIRES THAT THE MAXIMUM SYSTEM FLOW RATE
 DOES NOT EXCEED THE LISTED MAXIMUM FLOW RATE OF THE
 SUCTION OUTLET FITTING ASSEMBLY (DRAIN COVER). THE TDH
 CALCULATIONS MUST INCLUDE ALL THE SYSTEM COMPONENTS,
 INCLUDING SUCTION AND RETURN PIPING, FITTINGS, VALVES,
 HEATER, FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS
 EXCEPT THE PUMP.
  
 3. SUBMIT THE POOL PUMP CURVE. IDENTIFY THE PUMP CURVE
 WHICH CURVE KEY IS SPECIFIC TO THE PUMP BEING INSTALLED
 ON THIS POOL. THIS IS NEEDED TO CONFIRM THE MAXIMUM
 SYSTEM FLOW FROM THE TDH CALCULATIONS PER THE
 ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9, 4.4.9.1.
  
 4. SUBMIT THE MANUFACTURER'S SPECIFICATIONS FOR THE
 HEAT PUMP, CHLORINATOR, CARTRIDGE FILTER, AND THE PUMP
 PER THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 5. THE POOL HEATER SHALL HAVE A MINIMUM THERMAL
 EFFICIENCY OF 82% PER THE 2017 FBC-ENERGY SEC.
 R403.10.4.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2021-06-25 Cont ID  
Sent By medwards Date 2021-06-25 Time 11:44 Rev Time 0.00
Received By medwards Date 2021-06-25 Time 11:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-04-15 Cont ID  
Sent By equinone Date 2021-04-15 Time 09:39 Rev Time 0.00
Received By equinone Date 2021-04-14 Time 16:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-01-25 Cont ID  
Sent By medwards Date 2021-01-25 Time 11:10 Rev Time 0.00
Received By medwards Date 2021-01-25 Time 11:10 Sent To  
Notes
2021-01-25 11:25:23ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO
 STORAGE.ME

Review Stop Z ZONING
Rev No 1 Status P Date 2021-02-05 Cont ID  
Sent By rthermid Date 2021-02-02 Time 13:54 Rev Time 0.00
Received By fmittner Date 2021-02-02 Time 13:54 Sent To  
Notes
2021-02-02 13:54:42CORNER SIDE SETBACK (SOUTH) IS 15' MINIMUM