Plan Review Stops For Permit 21010762 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-02-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-02-23 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-02-23 |
Time |
15:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-02-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-02-10 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-02-10 |
Time |
15:51 |
Sent To |
|
|
Notes |
2021-02-10 16:10:59 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) GENERATOR EXHAUST IS REQUIRED TO BE 10' FROM ANY | | OPENINGS. R303.5.1 INTAKE OPENINGS. MECHANICAL AND | | GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED | | NOT LESS THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR | | NOXIOUS CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING | | VENTS, STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS. | | | | 2) THE GENERATOR PAD ENGINEERING THAT WAS SUBMITTED | | WILL NOT WORK FOR THE GENERATOR SPECIFICATIONS THAT WAS | | SUBMITTED. THIS PAD IS FOR LARGER 22 KW GENERAC | | GENERATORS. CHECK THE SERIAL NUMBERS, THE DIMENSIONS | | AND WEIGHT OF THE GENERATORS LISTED ON THE PAD | | ENGINEERING FOR COMPATIBLE GENERATORS. PLEASE SUBMIT | | MATCHING DOCUMENTS. FBC 107.2.1 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-02-23 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-02-23 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-02-23 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-02-04 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-02-04 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-02-04 |
Time |
14:22 |
Sent To |
|
|
Notes |
2021-02-04 14:24:33 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | 7TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | PLEASE SEE ALSO BUILDING REVIEW COMMENTS: | | | | 1) PLEASE SUBMIT RISER DIAGRAM SHOWING SERVICE | | EQUIPMENT, TRANSFER SWITCH, EMERGENCY GENERATOR. | | INCLUDE DISCONNECTING MEANS, BREAKERS AND CONDUCTOR | | SIZES. DRAWINGS NEED TO INCLUDE THE NAME, SIGNATURE AND | | LICENSE NUMBER OF CONTRACTOR QUALIFIER. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | ENRIQUE QUINONEZ P.E. | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-03-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-03-01 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-03-01 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-02-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-02-03 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-02-03 |
Time |
09:34 |
Sent To |
|
|
Notes |
2021-02-03 10:11:10 | 1ST REVIEW FBC-2020 RES. | | PERMIT- 21010762 | | 2/3/2021 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SUBMIT A GAS PIPING RISER DRAWING- SECTION | | 107.3.5.3 WPB AND SECTION G2413 FBC RES. | | | | 2) SURVEY: CORRECT THE 5 FT. CLEARANCE TO INDICATE | | REQUIRED 10 FT. FROM THE GENERATOR TO OPERABLE OPENING | | AND AIR INTAKES INTO THE BUILDING- SECTION R303.5.1 FBC | | RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-03-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-03-09 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-02-18 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-02-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-02-10 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-01-21 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2021-03-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-03-01 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-03-01 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2021-02-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-02-03 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-02-03 |
Time |
09:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-02-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-02-23 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-02-23 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-02-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-02-10 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-02-10 |
Time |
16:11 |
Sent To |
|
|
Notes |
2021-02-10 16:12:54 | THE WRONG GENERATOR PAD ENGINEERING WAS SUBMITTED. THE | | SIGNATURE ON THE RESUBMITTED DOCUMENTS WILL HAVE TO BE | | VERIFIED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-03-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-03-05 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-03-05 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-02-03 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-02-03 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2021-02-03 |
Time |
|
Sent To |
I |
|
Notes |
|
|