Plan Review Details - Permit 21010528
Plan Review Stops For Permit 21010528 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2021-02-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-02-23 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-02-23 |
Time |
11:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-20 |
Time |
17:27 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-20 |
Time |
17:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-02-11 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2021-02-11 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2021-02-11 |
Time |
08:24 |
Sent To |
|
|
Notes |
2021-02-11 09:22:39 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | 7TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | 2. 215.5 BREAKER, WIRE, AND CONDUIT SIZES | | 3.PROVIDE CUT SHEETS FOR EQUIPMENT | | 4. 680.26 EQUIPOTENTIAL BONDING BEFORE FINAL | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | SINCERELY, | | | | PHIL PETTY | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | 561-805-6742 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-20 |
Time |
17:27 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-04-08 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-03-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-03-05 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-02-03 |
Time |
16:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-02-08 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-02-05 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-02-05 |
Time |
13:33 |
Sent To |
|
|
Notes |
2021-02-05 13:41:04 | 02/05/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-04-20 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-04-20 |
Time |
17:27 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-02-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-02-23 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-02-23 |
Time |
11:10 |
Sent To |
|
|
Notes |
2021-02-23 11:14:11 | I COULD NOT VALIDATE THE DIGITAL SIGNATURES. | | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | 61G15 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-03-04 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-03-04 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-03-04 |
Time |
12:02 |
Sent To |
I |
|
Notes |
|
|
|