Plan Review Details - Permit 21010260
Plan Review Stops For Permit 21010260
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-04-16 Cont ID  
Sent By rmcphers Date 2021-04-16 Time 07:42 Rev Time 0.00
Received By rmcphers Date 2021-04-16 Time 07:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-03-12 Cont ID  
Sent By rmcphers Date 2021-03-12 Time 13:40 Rev Time 0.00
Received By rmcphers Date 2021-03-12 Time 13:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-02-16 Cont ID  
Sent By mcphers Date 2021-02-16 Time 09:42 Rev Time 0.00
Received By rmcphers Date 2021-02-16 Time 09:42 Sent To  
Notes
2021-02-16 10:00:43ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT
 APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE
 THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-52.5)
 - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE PRODUCT
 APPROVAL. (ZONE 1 = -31.0 ZONE 2 = -52.0 ZONE 3 =
 -78.0)
 2) PLEASE PROVIDE THE ADDITIONAL JOB COST ON THE
 REVISION FORM.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-01-22 Cont ID  
Sent By rmcphers Date 2021-01-22 Time 13:27 Rev Time 0.00
Received By rmcphers Date 2021-01-22 Time 13:13 Sent To  
Notes
2021-01-22 13:21:26ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DRAWINGS FOR PERMIT 20020932 DO NOT SHOW A FLAT
 ROOF. PLEASE PROVIDE A SITE PLAN SHOWING THE LOCATION
 OF THE FLAT ROOF TO BE INSTALLED.
 2) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT
 APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE
 THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-52.5)
 - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE PRODUCT
 APPROVAL.
 3) PLEASE PROVIDE THE ADDITIONAL JOB COST ON THE
 REVISION FORM.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2021-02-01 Cont ID  
Sent By aborngra Date 2021-02-01 Time 10:36 Rev Time 0.00
Received By aborngra Date 2021-02-01 Time 10:02 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2021-01-27 Cont ID  
Sent By aborngra Date 2021-01-27 Time 12:42 Rev Time 0.00
Received By aborngra Date 2021-01-27 Time 12:41 Sent To  
Notes
2021-01-27 12:42:23PERMIT HAS FAILED:
  
 WHAT IS THE FLAT ROOF BEING USED FOR? THE HOUSE DOES
 NOT HAVE A FLAT ROOF.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2021-05-19 Cont ID  
Sent By equinone Date 2021-05-19 Time 08:46 Rev Time 0.00
Received By equinone Date 2021-05-18 Time 17:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-05-03 Cont ID  
Sent By jgomez Date 2021-05-03 Time 16:40 Rev Time 0.00
Received By jgomez Date 2021-05-03 Time 15:52 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-04-16 Cont ID  
Sent By rmcphers Date 2021-04-16 Time 07:43 Rev Time 0.00
Received By rmcphers Date 2021-04-12 Time 11:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-03-12 Cont ID  
Sent By rmcphers Date 2021-03-12 Time 13:41 Rev Time 0.00
Received By rmcphers Date 2021-02-25 Time 07:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-02-16 Cont ID  
Sent By rmcphers Date 2021-02-16 Time 10:01 Rev Time 0.00
Received By rmcphers Date 2021-01-28 Time 16:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-27 Cont ID  
Sent By cpuell Date 2021-01-27 Time 12:51 Rev Time 0.00
Received By cpuell Date 2021-01-11 Time 13:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2021-05-19 Cont ID  
Sent By equinone Date 2021-05-19 Time 08:46 Rev Time 0.00
Received By equinone Date 2021-05-19 Time 08:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status F Date 2021-05-03 Cont ID  
Sent By jgomez Date 2021-05-03 Time 16:21 Rev Time 0.00
Received By jgomez Date 2021-05-03 Time 16:00 Sent To  
Notes
2021-05-03 16:37:39DIGITAL REVIEW COMMENT:
  
 1- ROOF FRAMING PLAN DATED 3/16/21 HAVE A COPY OF THE
 ARCHITECT'S DIGITAL SIGNATURE. THIS IS NOT ALLOWED.
 DRAWINGS WITH DIGITAL SIGNATURE NEED TO BE UPLOADED TO
 PROJECTDOX. SEC. 61G1-16.005 .
  
 ARCHITECTS
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
  
 OR PROVIDE HARD COPY PLANS WITH THE ORIGINAL SEAL AND
 SIGNATURE WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS
 AS REQUIRED BY 61G1-16.003 FAC.
  
  
 NOTE:
 RAS 117 CALCULATIONS WITH ENGINEER'S EMBOSSED SEAL AND
 ORIGINAL SIGNATURE MATCH APPROVED ONE. JG.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2021-04-16 Cont ID  
Sent By rmcphers Date 2021-04-16 Time 07:42 Rev Time 0.00
Received By rmcphers Date 2021-04-16 Time 07:42 Sent To  
Notes
2021-04-16 07:43:03THE ADDITIONAL ATTACHMENT LETTER FROM THE ENGINEER =
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR
 DIGITAL SIGNATURE ? YOU CAN MAIL IN OR DROP OFF THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE
 FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-03-12 Cont ID  
Sent By rmcphers Date 2021-03-12 Time 13:40 Rev Time 0.00
Received By rmcphers Date 2021-03-12 Time 13:40 Sent To  
Notes
2021-03-12 13:40:59SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR
 DIGITAL SIGNATURE ? YOU CAN MAIL IN OR DROP OFF THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE
 FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2021-02-16 Cont ID  
Sent By rmcphers Date 2021-02-16 Time 10:00 Rev Time 0.00
Received By rmcphers Date 2021-02-16 Time 10:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-01-22 Cont ID  
Sent By rmcphers Date 2021-01-22 Time 13:27 Rev Time 0.00
Received By rmcphers Date 2021-01-22 Time 13:27 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved