2021-01-26 12:27:44 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| SERVICES/ BUILDING DIVISION |
| 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 21010228 |
| ADD: 700 S. ROSEMARY AVE. |
| CONT: BUTLER CONSTRUCTION CO. |
| TEL: 561-832-9700 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. JAN. 26TH/2021 |
| ACTION: DENIED |
| |
| 1) PLEASE PROVIDE A SURVEY OF THE EXISTING COLUMNS IN |
| RELATIONSHIP TO THE NEW COLUMN DESIGN AND THE PROPERTY |
| LINE. THE OTHER ISSUE IS THE RELATIONSHIP (DISTANCE) |
| FROM THE PROPERTY LINE AND THE PROPOSED ALUMINUM |
| FRAMEWORK. 2020 FBC-B. CHAPTER 32 ENCROACHMENTS INTO |
| THE RIGHT OF WAY. THE 2020 FBC-B SECTIONS 3202.2.2, |
| 3202.3.2 & 3202.3 DO ALLOW FOR ARCHITECTURAL FEATURES |
| BEYOND THE LOT LINE ABOVE GRADE DEPENDING ON THEIR |
| HEIGHT ABOVE GRADE. |
| |
| 2) PLEASE CONTACT THE ENGINEERING DEPARTMENT, A RIGHT |
| OF WAY PERMIT MAY NEED TO BE OBTAINED TO DO WORK, OR |
| SET UP SCAFFOLDING IN THE RIGHT OF WAY. MAIN PHONE: |
| (561) 822-1200. 107.2.1.2. ADDITIONAL INFORMATION IS |
| REQUIRED. |
| |
| 3A) NEITHER THE COVERSHEET, INDEX SHEET NOR THE 1ST |
| ELEVATION SHEET A1.1.1 INDICATE THE MINIMUM |
| CONSTRUCTION TYPE. |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATIVE CODE SECTION: |
| 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND |
| OR STRUCTURES. |
| 107.3.5.1 COMMERCIAL BUILDINGS |
| 107.3.5.1.1. BUILDING |
| MINIMUM TYPE OF CONSTRUCTION |
| PLEASE NOTE WHEN CITY PLACE WAS BUILT THE MINIMUM |
| CONSTRUCTION TYPE IS II-B CONSTRUCTION. |
| |
| 3B) SHEET A4.0.1 WALL SECTIONS 1, 2 & 3 ALL STATE THE |
| NEW COLUMNS ARE TO BE CLAD WITH STRUCTURAL SHEATHING. |
| THE TYPE OF SHEATHING NOR THICKNESS OF THE SHEATHING IS |
| NOT NAMED. SHEET A5.0.1 THE RENDERING STATES PLYWOOD |
| SUBSTRATE. THE STRUCTURAL SHEETS DO NOT CALL OUT THE |
| SUB-SHEATHING EITHER. PLEASE REFER TO THE 2020 FBC-B |
| SECTION 603.1.1.2 FIRE RETARDANT TREATED WOOD SHALL BE |
| PERMITTED IN : 1.2 NONBEARING EXTERIOR WALLS WHERE FIRE |
| RESISTANCE RATED CONSTRUCTION IS NOT REQUIRED. |
| |
| 3C) SHEET A4.0.1 WALL SECTIONS 2 & 3 BOTH SHOW NEW ROOF |
| FRAMING MEMBERS AND SHEATHING, AGAIN THE TYPE OF |
| SHEATHING IS NOT CALLED OUT. SHEET S4.00 THE ROOF |
| SECTION DOES CALL OUT ? INCH FRT PLYWOOD FOR THE ROOF |
| TOP DECKING BUT THE FRONT WALL EXTENSION THE PLYWOOD IS |
| LISTED AS ? INCH STRUCTURAL SHEATHING NOT FIRE |
| RETARDANT TREATED PLYWOOD. 2020 FBC-B SECTION 603.1.1.2 |
| FIRE RETARDANT TREATED WOOD SHALL BE PERMITTED IN : 1.2 |
| NONBEARING EXTERIOR WALLS WHERE FIRE RESISTANCE RATED |
| CONSTRUCTION IS NOT REQUIRED. |
| |
| 4A) SHEET A4.0.1 DETAILS 2 & 3 BOTH SHOW A NEW FLAT |
| ROOF SECTION PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-B |
| SECTIONS 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA |
| DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE |
| 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY |
| OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE |
| PRODUCT APPROVALS: |
| (31) (D) ROOFING PRODUCTS AND ASSEMBLIES. |
| |
| 4B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE |
| 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP |
| DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD |
| PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC. |
| |
| 4C) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY |
| ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES |
| FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL |
| LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF |
| ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR |
| BOTH INSULATION & THE BASE SHEET AS CALCULATED IN |
| COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117. |
| CALCULATION PREPARED, SIGNED AND |
| SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR |
| REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS & |
| CLADDING. |
| |
| 5) SHEET A4.0.1. SHOWS A DECORATIVE ALUMINUM FRAME TO |
| BE DESIGNED BY A DELEGATED FABRICATOR, THIS CAN BE A |
| DEFERRED SUBMITTAL. DELEGATED ENGINEERING. 61G15-30.003 |
| ENGINEERING DOCUMENT CLASSIFICATION. FL 61G-15-30.006 |
| (3) THE DELEGATED ENGINEER SHALL FORWARD THE DELEGATED |
| ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR |
| REVIEW. |
| |
| 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS |
| SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE |
| PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE |
| TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO |
| THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. |
| DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR |
| APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED |
| DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST |
| THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS |
| FOR REVIEW BY THE BUILDING OFFICIAL. |
| |
| DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO |
| THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL |
| ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED |
| SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING |
| OFFICIAL. |
| |
| 6) THE ARCHITECTURAL AND STRUCTURAL SHEETS BOTH SHOW |
| THE USE OF EITHER WELDED AND OR BOLTED STEEL |
| CONNECTIONS. WELDED OR BOLTED CONNECTIONS. THE |
| CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE |
| SPECIFICATIONS & WELDER OPERATOR PERFORMANCE |
| QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED |
| STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON |
| THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL |
| BE REQUIRED. REPORTS SUBMITTED TO BUILDING INSPECTOR AT |
| TIME OF FRAMING INSPECTION. |
| 2020 FBC-B 2204.1 WELDING |
| 1. WELD PROCEDURES SPECIFICATIONS |
| 2. QUALIFICATIONS OF WELDING PERSONAL |
| 2020 FBC-B 2204.2 BOLTING. |
| IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, |
| PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD |
| AT 561-805-6666. |
| |
| 7) SHEET A4.01 DETAILS INDICATE THE USE OF IRONSPOT |
| BRICK VENEER CLADDING, PLEASE PROVIDE COMPLIANCE WITH |
| 1405.10.1.4 ADHERED MASONRY VENEERS. PLEASE PROVIDE |
| INSTALLATION INSTRUCTIONS AND LIMITATIONS FOR THIS |
| PRODUCT. |
| |
| 8) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| REVIEW CYCLE. |
| |
| PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| 19 |
| IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| 561-718-9724. |
| WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ |
| RETIRED. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |