Plan Review Stops For Permit 21010114 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-06-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-06-24 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-06-24 |
Time |
15:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-03-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-03-23 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-03-23 |
Time |
07:30 |
Sent To |
|
|
Notes |
2021-03-23 07:39:26 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE GENERATOR PAD DRAWING REFERENCES THE FBC SIXTH | | EDITION (2017) AND ASCE 7-10. THE FBC SEVENTH EDITION | | (2020) WENT INTO EFFECT ON DECEMBER 31, 2020 AND | | REFERENCES ASCE 7-16. ALL NEW PERMITS APPLIED FOR ON OR | | AFTER THAT DATE ARE REQUIRED TO COMPLY WITH AND | | REFERENCE THE 2020 FBC SEVENTH EDITION AND ASCE 7-16. | | FS CHAPTER 553 | | | | 2) THE NOTES ON THE SURVEY INDICATE THAT THE GENERATOR | | IS TO BE LOCATED 5 FEET FROM WINDOWS. THE GENERATOR | | EXHAUST IS REQUIRED TO BE 10 FEET FROM ANY OPENINGS | | INTO A STRUCTURE. FBC-R303.5.1 MECHANICAL AND GRAVITY | | OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS | | THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS | | CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, | | STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS. | | | | 3) A VERIFIABLE DIGITAL SIGNATURE IS REQUIRED ON | | ELECTRONICALLY SUBMITTED DRAWINGS. SEE SIGNATURE REVIEW | | COMMENTS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-03-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-03-17 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-03-17 |
Time |
08:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-06-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-06-01 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-06-01 |
Time |
17:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-04-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-05 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-05 |
Time |
14:47 |
Sent To |
|
|
Notes |
2021-04-05 15:58:02 | 1ST REVIEW FBC-2020 RES. | | PERMIT- 21010114 | | 4/5/2021 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) GAS RISER: PLEASE UPDATE THE FBC 2017 CODE | | REFERENCES TO THE CURRENT FBC 2020. | | | | 2) GAS RISER: PLEASE CORRECT THE 432,000 BTU GENERATOR | | LOAD TO 306,000 BTUS AS LISTED IN THE SUBMITTED | | GENERATOR SPECS- SECTION 107.2.1 WPB. | | | | 3) SURVEY: PLEASE CORRECT THE 5' GENERATOR DISTANCE | | FROM OPENINGS TO10' IN COMPLIANCE WITH R305.1 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-07-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-07-21 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-07-01 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-06-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-06-24 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-06-15 |
Time |
09:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-04-05 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-03-10 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2021-04-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-05 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-05 |
Time |
14:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-06-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-06-24 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-06-24 |
Time |
15:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-03-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-03-23 |
Time |
07:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-03-23 |
Time |
07:26 |
Sent To |
|
|
Notes |
2021-03-23 07:28:11 | THE GENERATOR PAD DRAWINGS DOES NOT HAVE AN ACCEPTABLE | | SIGNATURE. ELECTRONICALLY SUBMITTED DRAWINGS ARE | | REQUIRED TO HAVE THE ENGINEER'S DIGITAL SIGNATURE ON | | THEM. YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | TO BE VERIFIED. THE ENGINEER'S ORIGINAL HANDWRITTEN | | SIGNATURE AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. | | NO PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE | | ACCEPTABLE. FS 471 & 61G15 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2021-07-20 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-07-20 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-07-20 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-06-22 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-06-22 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-06-22 |
Time |
|
Sent To |
I |
|
Notes |
2021-06-22 10:21:55 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 6/22/2021 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. ON THE SUBMITTED SURVEY, PROVIDE THE SETBACKS OF THE | | GENERATOR FROM ALL PROPERTY LINES. PER THE CITY ZONING | | CODE, MECHANICAL EQUIPMENT CANNOT ENCROACH MORE THAN 4 | | FEET INTO A REQUIRED SETBACK. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561-822-1443 | | TTY: 800.955.8771 | | E: [email protected] | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-03-24 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-03-24 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2021-03-24 |
Time |
|
Sent To |
I |
|
Notes |
2021-03-24 13:43:17 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 3/24/2021 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. ADDRESS STRUCTURAL COMMENTS, PER THE FLORIDA | | BUILDING CODE MECHANICAL EQUIPMENT MUST BE SETBACK A | | MINIMUM OF 10 FEET FROM ANY OPENINGS, WINDOWS, | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | TTY: 800.955.8771 | | E: [email protected] | | W: WPB.ORG | | |
|
|