Plan Review Details - Permit 21010066
Plan Review Stops For Permit 21010066 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-12-09 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-12-09 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-12-09 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-01-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-25 |
Time |
08:14 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-22 |
Time |
15:22 |
Sent To |
|
|
Notes |
2021-01-25 08:14:48 | CANOPY | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE DOCUMENTS TO VERIFY REQUIREMENT OF | | FBC 3105.3.4.1 | | FABRIC USED FOR AWNINGS OR FABRIC-COVERED FRAMES SHALL | | MEET THE FLAME PROPAGATION PERFORMANCE CRITERIA OF NFPA | | 701 OR HAVE A FLAME SPREAD INDEX NOT GREATER THAN 25 | | WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723. | | 2) DRAWINGS 33,34 AND 35 NEED TO BE SIGNED AND SEALED | | BY THE ENGINEER OR ARCHITECT FBC 107.1 IF THE DESIGN | | PROFESSIONAL IS AN ARCHITECT, INTERIOR DESIGNER, | | LANDSCAPE ARCHITECT , OR ENGINEER LEGALLY | | REGISTERED UNDER THE LAWS OF THIS STATE REGULATING THE | | PRACTICE OF ARCHITECTURE OR INTERIOR DESIGN AS | | PROVIDED FOR IN CHAPTER 481, FLORIDA STATUTES, PART I, | | OR LANDSCAPE ARCHITECTURE AS PROVIDED FOR | | IN CHAPTER 481, FLORIDA STATUTES, PART II, OR | | ENGINEERING AS PROVIDED FOR IN CHAPTER 471, | | FLORIDA STATUTES, THEN HE OR SHE SHALL AFFIX HIS OR HER | | OFFICIAL SEAL TO SAID DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA, AS REQUIRED BY | | FLORIDA STATUTE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
P |
Date |
2021-12-17 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-12-17 |
Time |
06:58 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-12-15 |
Time |
16:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-12-09 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-12-09 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-12-03 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-01-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-25 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-08 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-12-17 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-12-17 |
Time |
06:57 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-12-17 |
Time |
06:57 |
Sent To |
|
|
Notes |
2021-12-15 16:39:49 | DIGITALLY SIGNED FILES UNDER SIGNATURES FOLDER IN | | PROJECTDOX |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-12-09 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-12-09 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-12-09 |
Time |
08:31 |
Sent To |
|
|
Notes |
2021-12-09 08:35:52 | SIGNATURE REVIEW | | | | NONE OF THE SIGNED AND SEALED DRAWINGS SHOW AS | | DIGITALLY SIGNED IN ADOBE READER - | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | DIVISION AT THE CITY HALL. | | | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-01-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-11 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-11 |
Time |
09:46 |
Sent To |
|
|
Notes |
2021-01-11 09:48:49 | PLEASE PROVIDE A TITLE BLOCK AND DESIGNER MUST EITHER | | DIGITALLY SIGN AND SEAL THE DRAWINGS OR THE ORIGINAL | | SIGNED AND SEALED PAPER DRAWINGS CAN BE BROUGHT TO OUR | | OFFICE. | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | 61G15?23.004 F.A.C. | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL | | HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE | | IS: (A) UNIQUE TO THE PERSON USING IT; (B) CAPABLE OF | | VERIFICATION; AS OF NOVEMBER 16, 2020 63 (C) UNDER THE | | SOLE CONTROL OF THE PERSON USING IT; AND, (D) LINKED TO | | A DOCUMENT IN SUCH A MANNER THAT THE DIGITAL SIGNATURE | | AND CORRESPONDINGLY THE DOCUMENT IS INVALIDATED IF ANY | | DATA IN THE DOCUMENT IS CHANGED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
Sent By |
avann |
Date |
2021-01-21 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2021-01-21 |
Time |
16:22 |
Sent To |
|
|
Notes |
|
|
|