Plan Review Details - Permit 21010023
Plan Review Stops For Permit 21010023
Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-29 Cont ID  
Sent By rcaranci Date 2022-03-29 Time 15:51 Rev Time 0.00
Received By rcaranci Date 2022-03-29 Time 10:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-03-25 Cont ID  
Sent By rcaranci Date 2022-03-25 Time 13:55 Rev Time 0.00
Received By rcaranci Date 2022-03-24 Time 16:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-21 Cont ID  
Sent By rcaranci Date 2022-03-21 Time 10:43 Rev Time 0.00
Received By rcaranci Date 2022-03-11 Time 08:29 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 3 Status P Date 2022-03-29 Cont ID  
Sent By rcaranci Date 2022-03-29 Time 15:51 Rev Time 0.00
Received By rcaranci Date 2022-03-29 Time 15:51 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 2 Status F Date 2022-03-25 Cont ID  
Sent By rcaranci Date 2022-03-25 Time 13:55 Rev Time 0.00
Received By rcaranci Date 2022-03-25 Time 13:55 Sent To  
Notes
2022-03-25 14:00:27RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM
 BEACH
  
 1. SATISFIED> SECTION 94-442(C)(2)A. SINGLE FAMILY
 DWELLING UNITS
 GROSS LOT SQUARE FOOTAGE MINUS
 BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
  
 4062.24 SQ FT
  
 ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
  
 5 TREES REQUIRED, REVISE PLAN, PROVIDE REQUIRED TREES.
  
 ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
  
 9 SHRUBS REQUIRED, THIS IS CORRECT.
  
 2. SECTION 94-442 (D) SUBSTITUTION OF PALM TREES.
 PALM TREES MAY BE SUBSTITUTED FOR NOT MORE THAN 35
 PERCENT OF THE SHADE OR FLOWERING TREES REQUIRED BY
 THIS ARTICLE. HOWEVER, WHEN PALM TREES ARE SUBSTITUTED
 FOR SHADE TREES, THREE PALM TREES SHALL BE PROVIDED FOR
 EACH REQUIRED SHADE TREE. THIS 3:1 SUBSTITUTION SHALL
 NOT BE REQUIRED FOR ROYAL PALM TREES (ROYSTONEA SPP.),
 SENEGAL DATE PALM (PHOENIX RECLINATA), MEDJOOL DATE
 PALM (PHOENIX DACTYLIFERA), BISMARCK PALM (BISMARCKIA
 NOBILIS), AND SILVER DATE PALM (PHOENIX SYLVESTRIS).
  
 FOR 5 REQUIRED TREES, MAXIMUM PALM SUBSTITUTION IS 1.
 IF USING THATCH PALMS AT 3:1, MUST MEET MINIMUM 8 FEET
 CLEAR WOOD HEIGHT REQUIREMENT.
 STILL NEED ONE MORE QUALIFYING TREE AND 3 QUALIFYING
 PALMS. FISHTAIL PALMS ARE NOT QUALIFYING.
 OR 2 MORE QUALIFYING TREES
  
 3. SECTION 94-442 (G) FLORIDA FRIENDLY LANDSCAPE
 REQUIREMENTS
 LANDSCAPE PLAN MUST SATISFY A MINIMUM TOTAL OF 25
 POINTS FROM THE DESIGN OPTIONS CHART.
  
 ST AUGUSTINE GRASS IS NOT ACCEPTED AS FLORIDA NATIVE SO
 CANNOT BE USED FOR POINTS CLAIMED. (ONLY 25 POINTS
 REQUIRED)
 REMOVE FROM POINTS.
 RECHECK POINTS AFTER CORRECTIONS MADE.
  
  
  
  
  
  
  
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2022-03-21 Cont ID  
Sent By rcaranci Date 2022-03-21 Time 10:43 Rev Time 0.00
Received By rcaranci Date 2022-03-21 Time 10:43 Sent To  
Notes
2022-03-21 10:52:00RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM
 BEACH
  
 1. SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS
 GROSS LOT SQUARE FOOTAGE MINUS
 BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
  
 4062.24 SQ FT
  
 ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
  
 5 TREES REQUIRED, REVISE PLAN, PROVIDE REQUIRED TREES.
  
 ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
  
 9 SHRUBS REQUIRED, THIS IS CORRECT.
  
 2. SECTION 94-442 (D) SUBSTITUTION OF PALM TREES.
 PALM TREES MAY BE SUBSTITUTED FOR NOT MORE THAN 35
 PERCENT OF THE SHADE OR FLOWERING TREES REQUIRED BY
 THIS ARTICLE. HOWEVER, WHEN PALM TREES ARE SUBSTITUTED
 FOR SHADE TREES, THREE PALM TREES SHALL BE PROVIDED FOR
 EACH REQUIRED SHADE TREE. THIS 3:1 SUBSTITUTION SHALL
 NOT BE REQUIRED FOR ROYAL PALM TREES (ROYSTONEA SPP.),
 SENEGAL DATE PALM (PHOENIX RECLINATA), MEDJOOL DATE
 PALM (PHOENIX DACTYLIFERA), BISMARCK PALM (BISMARCKIA
 NOBILIS), AND SILVER DATE PALM (PHOENIX SYLVESTRIS).
  
 FOR 5 REQUIRED TREES, MAXIMUM PALM SUBSTITUTION IS 1.
 IF USING THATCH PALMS AT 3:1, MUST MEET MINIMUM 8 FEET
 CLEAR WOOD HEIGHT REQUIREMENT.
  
 3. SECTION 94-442 (G) FLORIDA FRIENDLY LANDSCAPE
 REQUIREMENTS
 LANDSCAPE PLAN MUST SATISFY A MINIMUM TOTAL OF 25
 POINTS FROM THE DESIGN OPTIONS CHART.
  
 ST AUGUSTINE GRASS IS NOT ACCEPTED AS FLORIDA NATIVE SO
 CANNOT BE USED FOR POINTS CLAIMED. (ONLY 25 POINTS
 REQUIRED)
  
 RECHECK POINTS AFTER CORRECTIONS MADE.
  
  
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status N Date 2022-03-29 Cont ID  
Sent By rcaranci Date 2022-03-29 Time 15:51 Rev Time 0.00
Received By rcaranci Date 2022-03-29 Time 15:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status N Date 2022-03-25 Cont ID  
Sent By rcaranci Date 2022-03-25 Time 13:56 Rev Time 0.00
Received By rcaranci Date 2022-03-25 Time 13:55 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2022-03-21 Cont ID  
Sent By rcaranci Date 2022-03-21 Time 10:43 Rev Time 0.00
Received By rcaranci Date 2022-03-21 Time 10:43 Sent To  
Notes
***NONE***