Plan Review Stops For Permit 20121385 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-04-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-04-26 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-04-26 |
Time |
17:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-03-31 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-31 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-31 |
Time |
10:35 |
Sent To |
|
|
Notes |
2021-03-31 10:38:28 | SFR ADDITION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) NEW EXTERIOR DOORS AT EXISTING BEDROOM - PLEASE SHOW | | THE EXTERIOR LANDING TO COMPLY WITH FBC R311.3 FLOORS | | AND LANDINGS AT EXTERIOR DOORS. | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT | | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A | | DIMENSION OF NOT LESS THAN 36 INCHES (914 MM) MEASURED | | IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR | | LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS | | HORIZONTAL (2 PERCENT). | | 2) THE SITE PLAN NEEDS TO SHOW THE SETBACKS FOR THE | | ADDED ROOFED PATIO. | | | | DEFERRED SUBMITTALS: WINDOW AND DOOR PRODUCT APPROVALS, | | ROOFING SYSTEM. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-02-01 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-02-01 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-02-01 |
Time |
13:44 |
Sent To |
|
|
Notes |
2021-02-01 14:43:03 | SFR ADDITION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) CODE IN EFFECT CHANGED ON 1/1/2021 - PLEASE REVISE | | THE DRAWINGS TO SHOW THE DESIGN PER THE CODE IN EFFECT | | FBC 2020 AND ASCE 7-16 | | 2) JOB VALUE SHOWN ON THE BUILDING PERMIT APPLICATION | | APPEARS TO BE LOW - PLEASE PROVIDE A SIGNED CONTRACT TO | | VERIFY THE JOB COST. FBC WPB 109.3 BUILDING PERMIT | | VALUATIONS. IF, IN THE OPINION OF THE BUILDING | | OFFICIAL, THE CLAIMED VALUATION | | OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE | | APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL | | BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | LATEST PUBLISHED DATA OF NATIONAL | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL | | CODE CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE | | SET BY THE BUILDING OFFICIAL. | | | | DEFERRED SUBMITTALS: WINDOW AND DOOR PRODUCT APPROVALS, | | ROOFING SYSTEM. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-03-23 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-03-23 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-03-23 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-01-28 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-01-28 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-01-28 |
Time |
16:05 |
Sent To |
|
|
Notes |
2021-01-28 16:54:22 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | REVIEW STATUS: FAILED. | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1) BACK AND FRONT OF UNIT. GFI/WP OUTDOOR RECEPTACLES | | REQUIRED. NEC 210.8(A)(3) | | 2) LAUNDRY AREA: GFI RECEPTACLE REQUIRED. NEC | | 210.8(A)(10) | | 3) PANEL SCHEDULES A AND B: PLEASE PROVIDE AVAILABLE | | SHORT CIRCUIT CURRENT AT MAIN DISCONNECT AND SPECIFY | | AIC RATINGS FOR 250 AMPS DISCONNECT AND BOTH PANELS. | | 4) PLEASE SPECIFY IF PANELS HAVE MCB OR IF THEY MLO. | | FBC 107 | | 5) PLEASE SHOW AND IDENTIFY AND SHOW LOCATION OF | | DISCONNECTING MEANS FOR BOTH PANELS. PLEASE SPECIFY IF | | DISCONNECTS HAVE OCP AND IF YES SPECIFY BREAKER SIZES. | | FBC 107 | | 6) RISER DIAGRAM: PLEASE SPECIFY HOW FEEDER TO PANELS A | | AND B ARE PROTECTED. PANEL A FEEDER DOES NOT COMPLY | | WITH TAP RULES. IT ALSO SEEMS THAT DISTANCE FROM | | DISCONNECT TO PANEL B IS TOO LONG TO COMPLY WITH TAP | | RULES. SEE NOTES 4 AND 5 AS THESE ITEMS ARE RELATED. | | 7) ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | CORRECTION. NEC 210.12; FBC RE E3902.16 (A NOTE WILL | | SUFFICE) | | 8) TAMPER-RESISTANT RECEPTACLES REQUIRED AS PER FBC RE | | E4002.14 (A NOTE WILL SUFFICE) | | 9) NOTE 9 SPECIFIES A MINIMUM OF 50%. IT SHOULD BE 75%. | | SEE NOTE: PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT | | OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES | | SHALL BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT | | OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | FBC EC R404.1 | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-04-30 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2021-04-30 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2021-04-30 |
Time |
10:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-04-30 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2021-04-30 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2021-04-12 |
Time |
09:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-04-08 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-04-08 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-03-17 |
Time |
12:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-03-09 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-03-09 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-01-15 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-06-02 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-06-02 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-04-30 |
Time |
10:32 |
Sent To |
|
|
Notes |
2021-05-25 14:10:55 | RECEIPT MU-2021-25126 - $1945.04 - PAID | 2021-04-30 10:33:47 | 04/30/21 EMAILED PBC - IMPACT FEE QUESTIONNAIRE | | UPLAODED IN PROJECTDOX. CC |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-02-01 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-02-01 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-02-01 |
Time |
14:43 |
Sent To |
|
|
Notes |
2021-02-01 14:44:14 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-03-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2021-03-29 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2021-03-29 |
Time |
13:29 |
Sent To |
|
|
Notes |
2021-03-29 13:38:26 | 2ND REVIEW FBC-2020 MECHANICAL | | PERMIT-20121385 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THERE IS NO MECHANICAL PERMIT OR MECHANICAL | | CONTRACTOR FOR THIS PROJECT. PLEASE OBTAIN A MECHANICAL | | PERMIT AND IDENTIFY THE MECHANICAL CONTRACTOR FOR THIS | | PROJECT. | | | | 2) EITHER THE MECHANICAL CONTRACTOR CONTRACTED TO DO | | THIS PROJECT OR AND ENGINEER CAN DESIGN THE MECHANICAL | | SYSTEM. PLEASE HAVE THE MECHANICAL CONTRACTOR OR A | | LICENSED ENGINEER IN THE STATE OF FLORIDA WILL NEE TO | | SUBMIT THE DESIGN INCLUDING THE MECHANICAL EQUIPMENT | | SIZING CALCULATIONS. FS 471.003 (H) | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-01-21 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-21 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-21 |
Time |
13:15 |
Sent To |
|
|
Notes |
2021-01-21 13:30:15 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-20121385 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2020 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2020 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THE NEW | | ADDITION. | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-21 |
Time |
18:11 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-01-21 |
Time |
18:11 |
Sent To |
|
|
Notes |
2021-01-21 18:12:12 | 01/21/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2021-02-01 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-02-01 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-02-01 |
Time |
14:44 |
Sent To |
|
|
Notes |
2021-02-01 14:44:43 | DEFERRED SUBMITTAL |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-04-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-04-26 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-04-26 |
Time |
17:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-03-29 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-03-29 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-03-29 |
Time |
13:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-21 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-21 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2021-04-30 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-04-30 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-04-30 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-04-07 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-04-07 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-04-07 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-03-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-03-05 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2021-03-05 |
Time |
|
Sent To |
I |
|
Notes |
2021-03-05 12:14:16 | EXPANDING SINGLE FAMILY RESIDENCE. |
|
|