Plan Review Details - Permit 20121333
Plan Review Stops For Permit 20121333 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2021-02-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-02-18 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-02-18 |
Time |
08:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-02-08 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-02-08 |
Time |
20:09 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-02-08 |
Time |
19:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-04-06 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-04-06 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-04-06 |
Time |
12:45 |
Sent To |
|
|
Notes |
2021-04-06 12:50:27 | 04/06/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-02-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-02-19 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-02-19 |
Time |
12:51 |
Sent To |
|
|
Notes |
2021-02-19 13:52:28 | PLEASE PROVIDE THE DEVELOPED LENGTH TO THE FARTHEREST | | APPLIANCE FROM THE GAS SERVICE. FBC FG 402.4 | | PLEASE SHOW THE PRESSURE OF THE EXISTING PIPING SYSTEM. | | FBC107.2.1 | | PLASTIC PIPING MUST MEET SECTION 404.17, IT IS FOR | | OUTDOORS UNDERGROUND ONLY. | | PLEASE PROVIDE A GAS RISER DIAGRAM SHOWING ALL OF THE | | PIPING IN THIS SYSTEM. THE NOTE ADDED INDICATES THAT | | THE PIPING GOING INTO THE HOUSE IS THREE QUARTER INCH | | BUT THE INFORMATION EXPLAINING THE LENGTH OF PIPING | | GOING TO WATER HEATER AND THE HOUSE APPLIANCES | | INDICATES THIS PIPE AS ONE HALF INCH. PLEASE BE | | CONSISTENT | | THE PIPING SYSTEM SHOULD SHOW THE LOCATION OF ALL THE | | ADDED REGULATORS. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-04-13 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-04-13 |
Time |
08:05 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-03-12 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-02-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-02-19 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-26 |
Time |
08:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-04-06 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-04-06 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-04-06 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-02-02 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-02-02 |
Time |
20:53 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-02-02 |
Time |
20:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-04-06 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-04-06 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-04-06 |
Time |
12:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-02-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-02-18 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-02-18 |
Time |
08:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-04-12 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-04-12 |
Time |
16:54 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-02-11 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-02-11 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-02-11 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy