Plan Review Details - Permit 20121291
Plan Review Stops For Permit 20121291
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2021-06-02 Cont ID  
Sent By rmcphers Date 2021-06-02 Time 07:46 Rev Time 0.00
Received By rmcphers Date 2021-06-02 Time 07:46 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-05-06 Cont ID  
Sent By rmcphers Date 2021-05-06 Time 13:59 Rev Time 0.00
Received By rmcphers Date 2021-05-06 Time 13:59 Sent To  
Notes
2021-05-06 14:00:45PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-01-12 Cont ID  
Sent By rmcphers Date 2021-01-12 Time 13:44 Rev Time 0.00
Received By rmcphers Date 2021-01-12 Time 13:44 Sent To  
Notes
2021-01-12 13:45:24PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-05-06 Cont ID  
Sent By rmcphers Date 2021-05-06 Time 13:59 Rev Time 0.00
Received By rmcphers Date 2021-05-06 Time 13:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-01-12 Cont ID  
Sent By rmcphers Date 2021-01-12 Time 13:44 Rev Time 0.00
Received By rmcphers Date 2021-01-12 Time 12:43 Sent To  
Notes
2021-01-12 13:42:31REST ROOM REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DOOR SWING INTO CORRIDOR CANNOT BLOCK EGRESS PER FBC
 1005.7.1 DOORS.
 DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED
 WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY
 POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE
 THAN ONE-HALF.
 MINIMUM CORRIDOR SIZE (36") FBC TABLE 1020.2
 2) IT IS UNCLEAR AS TO THE LENGTH OF THE TOILET SIDE
 GRAB BAR - PLEASE CLARIFY FBC 604.5.1
 3) PLEASE CLARIFY THE FIXTURE CLEAR FLOOR SPACE BY
 ADDING THE DIMENSIONS FBC 305.3
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-05-03 Cont ID  
Sent By jleahy Date 2021-05-03 Time 07:36 Rev Time 0.00
Received By jleahy Date 2021-05-03 Time 07:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-01-13 Cont ID  
Sent By jleahy Date 2021-01-13 Time 06:50 Rev Time 0.00
Received By jleahy Date 2021-01-13 Time 06:43 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-04-22 Cont ID  
Sent By pleduc Date 2021-04-22 Time   Rev Time 0.00
Received By pleduc Date 2021-04-22 Time 12:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-12-31 Cont ID  
Sent By pleduc Date 2020-12-31 Time   Rev Time 0.00
Received By pleduc Date 2020-12-31 Time 12:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-05-06 Cont ID  
Sent By rmcphers Date 2021-05-06 Time 14:00 Rev Time 0.00
Received By rmcphers Date 2021-04-21 Time 14:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-15 Cont ID  
Sent By cpuell Date 2021-01-15 Time 15:07 Rev Time 0.00
Received By cpuell Date 2020-12-30 Time 15:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-04-29 Cont ID  
Sent By ccole Date 2021-04-29 Time 12:49 Rev Time 0.00
Received By ccole Date 2021-04-29 Time 10:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-01-08 Cont ID  
Sent By ccole Date 2021-01-08 Time 15:41 Rev Time 0.00
Received By ccole Date 2021-01-08 Time 13:02 Sent To  
Notes
2021-01-08 15:41:321ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20121291
 1/8/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A2.1: PLEASE PROVIDE THE CLEAR FLOOR SPACE
 DIMENSIONS FOR THE WATER CLOSETS, URINAL, AND
 LAVATORIES- SECTIONS 604.3.1, 605.3, & 606.2 FBC ACC.
  
 2) A1.1, A2.1: PROVIDE ACCESSIBLE COMPARTMENT DOOR
 DETAILS INCLUDING DOOR WIDTHS- SECTION 604.8.1.2 FBC
 ACC.
  
 3) A2.1: THE RESTROOM ELEVATIONS AND TYPICAL
 ACCESSORIES DETAILS DO NOT SHOW THE HEIGHTS OF THE
 MIRRORS FROM THE FINISHED FLOORS TO THE REFLECTIVE
 SURFACES; AND THE GRAB HEIGHTS MEASURED FROM THE
 FINISHED FLOORS TO THE TOP OF THE GRIPPING SURFACES-
 SECTIONS 603.3 & 609.4 FBC ACC.
 4) D1.1 & P1.1: BASED ON THE DRAWINGS A SLAB REPAIR
 DETAIL IS REQUIRED- SECTION 107.2.1 WPB.
  
 5) P1.1: PROVIDE A WATER RISER DRAWING SHOWING THE NEW
 HOT AND COLD WATER SUPPLY PIPING TO THE FIXTURES-
 TABLES 604.3, 604.4, 604.5 FBC P AND SECTION
 107.3.5.1.3 WPB.
  
 6) P1.1: SHOW HOW TEMPERED WATER WILL BE PROVIDED TO
 THE NEW LAVATORIES- SECTION 416.5 FBC P.
  
 7) P1.1: PROVIDE THE LENGTH OF THE HOT WATER PIPING
 FROM THE HOT WATER SOURCE TO THE LAVATORIES- REFER TO
 SECTIONS C404.5.1 & C5404.5.2 FBC EC.
  
 8) P1.1: A HUB DRAIN DETAIL AND KEYNOTES ARE PROVIDED
 THAT APPEAR TO INDICATE PLUMBING WORK IN THE KITCHEN.
 PLEASE PROVIDE THE CORRELATING PLUMBING PLANS AND
 DETAILS- SECTION 1107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-05-06 Cont ID  
Sent By rmcphers Date 2021-05-06 Time 13:59 Rev Time 0.00
Received By rmcphers Date 2021-05-06 Time 13:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-01-12 Cont ID  
Sent By rmcphers Date 2021-01-12 Time 13:45 Rev Time 0.00
Received By rmcphers Date 2021-01-12 Time 13:45 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-01-13 Cont ID  
Sent By rthermid Date 2021-01-13 Time   Rev Time  
Received By rthermid Date 2021-01-13 Time   Sent To I
Notes
***NONE***