Plan Review Details - Permit 20121242
Plan Review Stops For Permit 20121242
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-01-12 Cont ID  
Sent By cpuell Date 2021-01-12 Time 10:06 Rev Time 0.00
Received By cpuell Date 2021-01-12 Time 10:06 Sent To  
Notes
2021-01-12 10:08:37NEW BUILDING WILL HAVE ADDRESS OF 222 COSTELLO RD,
 UNITY OF TITLE STILL NEEDED.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-01-04 Cont ID  
Sent By cpuell Date 2021-01-04 Time 14:38 Rev Time 0.00
Received By cpuell Date 2021-01-04 Time 14:38 Sent To  
Notes
2021-01-04 14:41:49NEEDS UNITY OF TITLE AND AN NEW PROPERTY CONTROL NUMBER
 FROM THE COUNTY. NEW ADDRESS WILL ALSO NEED TO BE
 ASSIGNED PLEASE REACH OUT TO CPUELL@ WPB.ORG TO DISCUSS
 THE ADDRESSING ISSUES. PLEASE REACH OUT TO VINCE NOEL
 [email protected] TO DISCUSS THE PROCESS FOR THE UNITY OF
 TITLE. ONCE YOU RECIEVE THE UNITY OF TITLE YOU WILL
 NEED TO REACH OUT TO THE COUNTY TO GET A NEW PCN.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-04-23 Cont ID  
Sent By cthroop Date 2021-04-23 Time 08:54 Rev Time 0.00
Received By cthroop Date 2021-04-22 Time 17:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-01-07 Cont ID  
Sent By cthroop Date 2021-01-07 Time 14:12 Rev Time 0.00
Received By cthroop Date 2021-01-07 Time 08:48 Sent To  
Notes
2021-01-07 14:40:36PLAN REVIEW / BUILDING
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2014 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SCOPE OF WORK APPEARS TO INCLUDE THE SUBSTANTIAL
 DEMOLITION OF THE EXISTING STRUCTURE. PROVIDE A DEMO
 PLAN. DETAIL WHAT IS BEIN DEMOLISHED.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. DELETE - N/A
  
 3. PROVIDE THE FINISHED FLOOR ELEVATION.
 R403.1.7.3 FOUNDATION ELEVATION.
 ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION
 SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER
 AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED
 DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2
 PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO
 THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN
 BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF
 DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT
 ALL LOCATIONS ON THE SITE.
  
 4. PROVIDE A SOILS REPORT.
 R401.4 SOIL TESTS.
 WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL
 SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE,
 SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE
 LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL
 DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE
 THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION.
 THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN
 APPROVED METHOD.
  
 5. PRODUCT APPROVALS INCLUDE 5 DOOR PRODUCT APPROVALS,
 1 DOOR NOA, 3 WINDOW PRODUCT APPROVALS, 3 WINDOW NOA'S,
 CONCRETE ROOF TILE PRODUCT APPROVALS, METAL ROOFING
 PRODUCT APPROVALS, BAHAMA SHUTTER PRODUCT APPROVALS,
 PANEL WALL PRODUCT APPROVALS.
 DESIGNER SHALL REVIEW PRODUCT APPROVALS AND REMOVE ANY
 THAT DO NOT APPLY TO THIS PROJECT.
 DESIGNER SHALL SELECT SPECIFIC MODEL OF DOORS AND
 WINDOWS ON PRODUCT APPROVALS. IF NON-IMPACT RATED,
 PROVIDE OPENING PROTECTION/SHUTTER SCHEDULE AND SHUTTER
 PRODUCT APPROVALS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS.
  
 6. PROVIDE A WINDOW AND DOOR SCHEDULE. INCLUDE THE
 FOLLOWING:
  
 6A) WINDOW SCHEDULE
  
 ITEM NUMBER/LOCATION ON
 PLAN/TYPE/MFGR./MATERIAL/GLASS/TREATMENT/ROUGH
 OPENING/IMPACT RESISTANT Y/N/PRODUCT APPROVAL
 NUMBER/NOA DESIGN PRESSURE RATING/OPENING REQUIRED
 PRESSURE RATING/EGRESS REQUIRED Y/N/SHUTTER REQUIRED
 Y/N
  
 6B) DOOR SCHEDULE
  
 ITEM NUMBER/LOCATION ON
 PLAN/SIZE/THICKNESS/TYPE/MFGR./MATERIAL/JAM/
 ROUGH OPENING/HARDWARE/NOA DESIGN PRESSURE
 RATING/OPENING REQUIRED PRESSURE RATING/SHUTTER
 REQUIRED Y/N
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-04-23 Cont ID  
Sent By cthroop Date 2021-04-23 Time 08:52 Rev Time 0.00
Received By cthroop Date 2021-04-22 Time 17:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-01-07 Cont ID  
Sent By cthroop Date 2021-01-07 Time 13:45 Rev Time 0.00
Received By cthroop Date 2021-01-07 Time 08:48 Sent To  
Notes
2021-01-07 13:51:45PLAN REVIEW / ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2014 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE ACTUAL TRANSFORMER SECONDARY FAULT CURRENT
 FROM UTILITY.
  
 AIC RATING OF SERVICE DISCONNECT AND PANEL
  
 PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10; FBC RE E3404.2 & FBC RE E3606.3
  
 FBC R E3606.3AVAILABLE SHORT-CIRCUIT CURRENT.
 SERVICE EQUIPMENT SHALL BE SUITABLE FOR THE MAXIMUM
 FAULT CURRENT AVAILABLE AT ITS SUPPLY TERMINALS, BUT
 NOT LESS THAN 10,000 AMPERES. (110.9)
 E3706.1PANELBOARD RATING.
 ALL PANELBOARDS SHALL HAVE A RATING NOT LESS THAN THAT
 OF THE MINIMUM SERVICE OR FEEDER CAPACITY REQUIRED FOR
 THE CALCULATED LOAD. (408.30)
  
 E3404.2INTERRUPTING RATING.
  
 EQUIPMENT INTENDED TO INTERRUPT CURRENT AT FAULT LEVELS
 SHALL HAVE A MINIMUM INTERRUPTING RATING OF 10,000
 AMPERES. EQUIPMENT INTENDED TO INTERRUPT CURRENT AT
 LEVELS OTHER THAN FAULT LEVELS SHALL HAVE AN
 INTERRUPTING RATING AT NOMINAL CIRCUIT VOLTAGE OF NOT
 LESS THAN THE CURRENT THAT MUST BE INTERRUPTED. (110.9)
  
 PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. NEC
 110.3, 110.9; FBC RE E3606.4
  
 PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE MARKED
 WITH THE MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT
 AVAILABLE PER NEC 110.24 & FBC RE E3606.4
  
 2. DELETE-N/A
  
 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 2 Status P Date 2021-04-23 Cont ID  
Sent By cthroop Date 2021-04-23 Time 08:53 Rev Time 0.00
Received By cthroop Date 2021-04-22 Time 17:12 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-01-07 Cont ID  
Sent By cthroop Date 2021-01-07 Time 13:51 Rev Time 0.00
Received By cthroop Date 2021-01-07 Time 10:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-28 Cont ID  
Sent By lmarchan Date 2021-04-28 Time 10:04 Rev Time 0.00
Received By lmarchan Date 2021-03-31 Time 11:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-04 Cont ID  
Sent By lmarchan Date 2021-02-04 Time 14:45 Rev Time 0.00
Received By lmarchan Date 2020-12-30 Time 16:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-05-18 Cont ID  
Sent By lmarchan Date 2021-05-18 Time 13:15 Rev Time 0.00
Received By lmarchan Date 2021-05-04 Time 14:02 Sent To  
Notes
2021-05-18 13:15:51RECEIPT - MU-2021-024069 - $0.00 DUE
2021-05-04 14:02:585/4/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-01-07 Cont ID  
Sent By cthroop Date 2021-01-07 Time 09:50 Rev Time 0.00
Received By cthroop Date 2021-01-07 Time 09:49 Sent To  
Notes
2021-01-07 09:50:40PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-04-08 Cont ID  
Sent By medwards Date 2021-04-08 Time 09:46 Rev Time 0.00
Received By medwards Date 2021-04-08 Time 09:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-01-07 Cont ID  
Sent By medwards Date 2021-01-07 Time 10:33 Rev Time 0.00
Received By medwards Date 2021-01-07 Time 10:18 Sent To  
Notes
2021-01-07 10:34:101ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20121242
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE AHU-2 TOTAL CFM?S IS LABELED AS 600, BUT
 COUNTING THE CFM?S AT EACH GRILLE THE TOTAL THERE IS
 1222 CFM?S. PLEASE SIZE THE AHU-2 FOR THE CFM?S NEEDED
 IN EACH ROOM. FBC EC R403.7
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-01-05 Cont ID  
Sent By lcrespo Date 2021-01-05 Time 06:44 Rev Time 0.00
Received By lcrespo Date 2021-01-05 Time 06:22 Sent To  
Notes
2021-01-05 06:44:5301/05/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2021-01-07 Cont ID  
Sent By cthroop Date 2021-01-07 Time 10:31 Rev Time 0.00
Received By cthroop Date 2021-01-07 Time 08:48 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-04-08 Cont ID  
Sent By medwards Date 2021-04-08 Time 09:53 Rev Time 0.00
Received By medwards Date 2021-04-08 Time 09:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-01-07 Cont ID  
Sent By cthroop Date 2021-01-07 Time 13:52 Rev Time 0.00
Received By cthroop Date 2021-01-07 Time 08:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-04-23 Cont ID  
Sent By kalexand Date 2021-04-23 Time 15:13 Rev Time 0.00
Received By kalexand Date 2021-04-23 Time 15:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-02-02 Cont ID  
Sent By kalexand Date 2021-02-02 Time 00:04 Rev Time 0.00
Received By kalexand Date 2021-02-02 Time 00:04 Sent To I
Notes
2021-02-02 00:05:59ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW:
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED HOME ON AN
 ELEVATION PLAN. PURSUANT TO THE ZLDR, SECTION 94-611,
 HEIGHT OF STRUCTURE MEANS THE VERTICAL DISTANCE FROM
 THE AVERAGE ELEVATION OF THE FINISHED GRADE OF THE
 STRUCTURE TO THE HIGHEST PORTION OF THE STRUCTURE,
 SUBJECT TO SPECIFIED HEIGHT REQUIREMENTS OF THIS
 CHAPTER. FOR BUILDINGS, THE HEIGHT SHALL BE MEASURED AS
 THE VERTICAL DISTANCE FROM THE AVERAGE ELEVATION OF THE
 FINISHED GRADE OF THE BUILDING TO THE HIGHEST POINT OF
 THE TOP OF THE STRUCTURE OF A FLAT ROOF, OR TO THE DECK
 LINE OF A MANSARD ROOF, OR TO THE MEAN HEIGHT LEVEL
 BETWEEN EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL
 ROOFS.
  
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALLY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG
 IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 KIZZI ALEXANDRE, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1442
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved