Plan Review Stops For Permit 20121242 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2021-01-12 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-01-12 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-01-12 |
Time |
10:06 |
Sent To |
|
|
Notes |
2021-01-12 10:08:37 | NEW BUILDING WILL HAVE ADDRESS OF 222 COSTELLO RD, | | UNITY OF TITLE STILL NEEDED. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2021-01-04 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-01-04 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-01-04 |
Time |
14:38 |
Sent To |
|
|
Notes |
2021-01-04 14:41:49 | NEEDS UNITY OF TITLE AND AN NEW PROPERTY CONTROL NUMBER | | FROM THE COUNTY. NEW ADDRESS WILL ALSO NEED TO BE | | ASSIGNED PLEASE REACH OUT TO CPUELL@ WPB.ORG TO DISCUSS | | THE ADDRESSING ISSUES. PLEASE REACH OUT TO VINCE NOEL | | [email protected] TO DISCUSS THE PROCESS FOR THE UNITY OF | | TITLE. ONCE YOU RECIEVE THE UNITY OF TITLE YOU WILL | | NEED TO REACH OUT TO THE COUNTY TO GET A NEW PCN. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-04-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-23 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-22 |
Time |
17:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-07 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-07 |
Time |
08:48 |
Sent To |
|
|
Notes |
2021-01-07 14:40:36 | PLAN REVIEW / BUILDING | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2014 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SCOPE OF WORK APPEARS TO INCLUDE THE SUBSTANTIAL | | DEMOLITION OF THE EXISTING STRUCTURE. PROVIDE A DEMO | | PLAN. DETAIL WHAT IS BEIN DEMOLISHED. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2. DELETE - N/A | | | | 3. PROVIDE THE FINISHED FLOOR ELEVATION. | | R403.1.7.3 FOUNDATION ELEVATION. | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | ALL LOCATIONS ON THE SITE. | | | | 4. PROVIDE A SOILS REPORT. | | R401.4 SOIL TESTS. | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | APPROVED METHOD. | | | | 5. PRODUCT APPROVALS INCLUDE 5 DOOR PRODUCT APPROVALS, | | 1 DOOR NOA, 3 WINDOW PRODUCT APPROVALS, 3 WINDOW NOA'S, | | CONCRETE ROOF TILE PRODUCT APPROVALS, METAL ROOFING | | PRODUCT APPROVALS, BAHAMA SHUTTER PRODUCT APPROVALS, | | PANEL WALL PRODUCT APPROVALS. | | DESIGNER SHALL REVIEW PRODUCT APPROVALS AND REMOVE ANY | | THAT DO NOT APPLY TO THIS PROJECT. | | DESIGNER SHALL SELECT SPECIFIC MODEL OF DOORS AND | | WINDOWS ON PRODUCT APPROVALS. IF NON-IMPACT RATED, | | PROVIDE OPENING PROTECTION/SHUTTER SCHEDULE AND SHUTTER | | PRODUCT APPROVALS. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | 6. PROVIDE A WINDOW AND DOOR SCHEDULE. INCLUDE THE | | FOLLOWING: | | | | 6A) WINDOW SCHEDULE | | | | ITEM NUMBER/LOCATION ON | | PLAN/TYPE/MFGR./MATERIAL/GLASS/TREATMENT/ROUGH | | OPENING/IMPACT RESISTANT Y/N/PRODUCT APPROVAL | | NUMBER/NOA DESIGN PRESSURE RATING/OPENING REQUIRED | | PRESSURE RATING/EGRESS REQUIRED Y/N/SHUTTER REQUIRED | | Y/N | | | | 6B) DOOR SCHEDULE | | | | ITEM NUMBER/LOCATION ON | | PLAN/SIZE/THICKNESS/TYPE/MFGR./MATERIAL/JAM/ | | ROUGH OPENING/HARDWARE/NOA DESIGN PRESSURE | | RATING/OPENING REQUIRED PRESSURE RATING/SHUTTER | | REQUIRED Y/N | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-04-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-23 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-22 |
Time |
17:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-07 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-07 |
Time |
08:48 |
Sent To |
|
|
Notes |
2021-01-07 13:51:45 | PLAN REVIEW / ELECTRICAL | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2014 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE ACTUAL TRANSFORMER SECONDARY FAULT CURRENT | | FROM UTILITY. | | | | AIC RATING OF SERVICE DISCONNECT AND PANEL | | | | PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | NEC 110.9, 110.10; FBC RE E3404.2 & FBC RE E3606.3 | | | | FBC R E3606.3AVAILABLE SHORT-CIRCUIT CURRENT. | | SERVICE EQUIPMENT SHALL BE SUITABLE FOR THE MAXIMUM | | FAULT CURRENT AVAILABLE AT ITS SUPPLY TERMINALS, BUT | | NOT LESS THAN 10,000 AMPERES. (110.9) | | E3706.1PANELBOARD RATING. | | ALL PANELBOARDS SHALL HAVE A RATING NOT LESS THAN THAT | | OF THE MINIMUM SERVICE OR FEEDER CAPACITY REQUIRED FOR | | THE CALCULATED LOAD. (408.30) | | | | E3404.2INTERRUPTING RATING. | | | | EQUIPMENT INTENDED TO INTERRUPT CURRENT AT FAULT LEVELS | | SHALL HAVE A MINIMUM INTERRUPTING RATING OF 10,000 | | AMPERES. EQUIPMENT INTENDED TO INTERRUPT CURRENT AT | | LEVELS OTHER THAN FAULT LEVELS SHALL HAVE AN | | INTERRUPTING RATING AT NOMINAL CIRCUIT VOLTAGE OF NOT | | LESS THAN THE CURRENT THAT MUST BE INTERRUPTED. (110.9) | | | | PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. NEC | | 110.3, 110.9; FBC RE E3606.4 | | | | PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE MARKED | | WITH THE MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT | | AVAILABLE PER NEC 110.24 & FBC RE E3606.4 | | | | 2. DELETE-N/A | | | | 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
2 |
Status |
P |
Date |
2021-04-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-23 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-22 |
Time |
17:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-07 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-07 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-04-28 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-04-28 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-03-31 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-02-04 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-02-04 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-12-30 |
Time |
16:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-05-18 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-05-18 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-05-04 |
Time |
14:02 |
Sent To |
|
|
Notes |
2021-05-18 13:15:51 | RECEIPT - MU-2021-024069 - $0.00 DUE | 2021-05-04 14:02:58 | 5/4/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-07 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-07 |
Time |
09:49 |
Sent To |
|
|
Notes |
2021-01-07 09:50:40 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-04-08 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-04-08 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-07 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-07 |
Time |
10:18 |
Sent To |
|
|
Notes |
2021-01-07 10:34:10 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20121242 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE AHU-2 TOTAL CFM?S IS LABELED AS 600, BUT | | COUNTING THE CFM?S AT EACH GRILLE THE TOTAL THERE IS | | 1222 CFM?S. PLEASE SIZE THE AHU-2 FOR THE CFM?S NEEDED | | IN EACH ROOM. FBC EC R403.7 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-01-05 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-05 |
Time |
06:44 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-01-05 |
Time |
06:22 |
Sent To |
|
|
Notes |
2021-01-05 06:44:53 | 01/05/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-07 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-07 |
Time |
08:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-04-08 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-04-08 |
Time |
09:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-07 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-07 |
Time |
08:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-04-23 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-04-23 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-04-23 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-02-02 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-02-02 |
Time |
00:04 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-02-02 |
Time |
00:04 |
Sent To |
I |
|
Notes |
2021-02-02 00:05:59 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED HOME ON AN | | ELEVATION PLAN. PURSUANT TO THE ZLDR, SECTION 94-611, | | HEIGHT OF STRUCTURE MEANS THE VERTICAL DISTANCE FROM | | THE AVERAGE ELEVATION OF THE FINISHED GRADE OF THE | | STRUCTURE TO THE HIGHEST PORTION OF THE STRUCTURE, | | SUBJECT TO SPECIFIED HEIGHT REQUIREMENTS OF THIS | | CHAPTER. FOR BUILDINGS, THE HEIGHT SHALL BE MEASURED AS | | THE VERTICAL DISTANCE FROM THE AVERAGE ELEVATION OF THE | | FINISHED GRADE OF THE BUILDING TO THE HIGHEST POINT OF | | THE TOP OF THE STRUCTURE OF A FLAT ROOF, OR TO THE DECK | | LINE OF A MANSARD ROOF, OR TO THE MEAN HEIGHT LEVEL | | BETWEEN EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL | | ROOFS. | | | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1442 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|