Plan Review Details - Permit 20121151
Plan Review Stops For Permit 20121151
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-01-04 Cont ID  
Sent By cpuell Date 2021-01-04 Time 12:44 Rev Time 0.00
Received By cpuell Date 2021-01-04 Time 12:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-04-13 Cont ID  
Sent By jgomez Date 2021-04-12 Time 17:59 Rev Time 0.00
Received By jgomez Date 2021-04-12 Time 15:27 Sent To  
Notes
2021-04-13 08:54:02BUILDING REVIEW APPROVED WITH PROVISO:
 1- ONLY SPECIAL 24EH PGT SINGLE HUNG WINDOW MEETS THE
 EGRESS CRITERIA FOR 2ND FLOOR BEDROOMS. IF WINDOW
 MANUFACTURER AND MODEL IS REVISED, THEN NEW PRODUCT
 APPROVALS REQUIRES REVISION SUBMITTED FOR
 REVIEW/APPROVAL.
  
 2-PROVIDE PRODUCT APPROVAL FOR:
 A)WOOD ENTRY DOOR AS SPECIFIED ON PLANS AND DOOR
 SCHEDULE.
 B)HARDIE BOARD SIDING AS SPECIFIED ON PLANS.
 FLORIDA PRODUCT APPROVAL FL13192-R6 SUBMITTED IS
 PENDING FBC APPROVAL.
  
 3-ARCHITECT TO REVIEW/APPROVE ABOVE PRODUCT APPROVALS.
  
 4-PROVIDE HANDRAILS AND GUARDRAILS SHOP DRAWINGS
 REVIEWED BY THE DESIGN PROFESSIONAL OF RECORD.
  
 5-PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR FACTORY
 BUILT FIREPLACE AND FACTORY BUILT CHIMNEY.
 NOTE: ARCHITECT TO REVIEW/APPROVE PRIOR TO SUBMITTAL TO
 THIS OFFICE.
  
 6- NOTE ON PROPOSED SITE PLAN SHEET A0.01:
 SURFACE RAIN WATER CAN NOT BE DIVERTED TOWARD ADJACENT
 PROPERTIES. SEC. 110.9 CITY AMENDMENTS.
 WATER SHALL BE GRADED AWAY FROM FOUNDATIONS. SEC.
 R401.3 FBC-RESIDENTIAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-02-23 Cont ID  
Sent By jgomez Date 2021-02-23 Time 17:01 Rev Time 0.00
Received By jgomez Date 2021-02-23 Time 17:00 Sent To  
Notes
2021-02-23 17:03:27RESPONSE TO EMAIL DATED 02/23/21.
  
 GOOD AFTERNOON,
 PLEASE NOTE THAT SIZE CHART SHOWN IS FOR SERIES SH4000
 & SH600 SINGLE HUNG PGT WINDOWS. PRODUCT APPROVAL
 SUBMITTED IS FOR SERIES SH7700A SINGLE HUNG WINDOWS.
 PLEASE COORDINATE ACCORDINGLY.
 WHEN RESUBMITTING, PLEASE PROVIDE ALL MANUFACTURE?S CUT
 SHEETS SHOWING ALL THE CLEAR OPENINGS OF THE SPECIFIED
 WINDOW SIZE AND MODEL.
  
 THANK YOU
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
 FROM: RAFAEL RODRIGUEZ
 SENT: TUESDAY, FEBRUARY 23, 2021 10:02 AM
 TO: CLAIRE GALLAGHER ; JULIO
 C. GOMEZ ; STEVEN KENNEDY
 
 CC: L GALLAGHER ;
 [email protected]
 SUBJECT: PERMIT # 20221151-COMMENT #1
  
 PLEASE NOTE PGT WINDOW 24 EH IS AN EGRESS WINDOW
 ACCORDING TO PGT INDUSTRIES-37 WIDE X 59.5 HIGH. I WAS
 CALLING THE WINDOW 24 SH, BUT IT IS ACTUALLY 24 EH..
 MEETS 5.7 EGRESS OPENING. PLEASE CONTACT ME IF YOU HAVE
 ANY QUESTIONS
  
 R A F A E L R O D R I G U E Z
 5 6 1 . 3 1 2 . 5 9 2 1
  
  
  
  
  
  
 NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 PERMIT #20121151
  
 1- BASED ON THE WINDOW SCHEDULE ON SHEET A7.01 IT LOOKS
 LIKE THE SIZE OF SINGLE HUNG WINDOW SPECIFIED (3'-1" X
 5'-0") SPECIFIED BY THE ARCHITECT DOESN'T COMPLY WITH
 THE MINIMUM CLEAR OPENING REQUIREMENTS OF SEC. R310.2.1
 FBC-RESIDENTIAL. TYPICALLY A 60" HEIGHT IMPACT SINGLE
 HUNG WINDOW DOESN'T PROVIDE THE REQUIRED 24" CLEAR
 HEIGHT OPENING. PROVIDE MANUFACTURER'S CUT SHEETS
 SHOWING THAT THE SPECIFIED 37"X60" SINGLE HUNG WINDOW
 MEETS ALL THE EGRESS REQUIREMENTS, INCLUDING THE CLEAR
 OPENING HEIGHT AND TOTAL CLEAR OPENING OF 5.7 S.F.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 2- PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. R401.4
 FBC-RESIDENTIAL. THIS PROPERTY IS LOCATED IN
 QUESTIONABLE SOILS.
  
 3-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
  
 4-ENERGY CALCULATIONS:
 A)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER'S NAME AND BUILDER'S NAME. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)CEILING TYPE ITEM #10(A) ON PAGE 1 OF 4 IS INCORRECT.
 ACCORDING TO PLANS THE ATTIC IS NOT VENTED. SEE PLANS
 AND REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 C)PROJECT INFORMATION ON PAGE 2 OF 4 SPECIFIES 1 STORY
 BUILDING. THIS IS INCORRECT. THIS IS A TWO STORY
 BUILDING. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D)ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 IS INCORRECT.
 PLANS AND PRODUCT APPROVALS SUBMITTED ARE FOR ASPHALT
 SHINGLES NOT WOOD SHINGLES. SEE PLANS AND REVISE AS
 REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 E)ATTIC INFORMATION SPECIFIED ON PAGE 2 OF 4 IS
 INCORRECT. PLANS DON'T SPECIFY ATTIC VENTILATION. ATTIC
 IS DESIGNED AS UNVENTED. SEE PLANS AND REVISE ALL THE
 ATTIC VENTILATION AS REQUIRED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 F)BUILDER TO SIGN THE ENERGY PERFORMANCE LEVEL (EPL)
 DISPLAY CARD SUBMITTED. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL):
  
 A)WOOD ENTRY DOOR AS SPECIFIED ON PLANS AND DOOR
 SCHEDULE.
  
 B)HARDIE BOARD SIDING AS SPECIFIED ON PLANS.
  
 6-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 7- PLANS SHOW A REAR PATIO WITH A ROOF PITCH OF 3:12.
 DESIGNER OF RECORD TO SPECIFY DOUBLE UNDERLAYMENT AS
 REQUIRED BY SEC. R905.2.2 FBC-RESIDENTIAL.
 NOTE: SAME COMMENT APPLIES TO MAIN ROOF OVERHANG. IT
 ALSO SHOWS A 3:12 PITCH.
  
 8- PROVISO:
 A)HANDRAILS AND GUARDRAILS DEFERRED SUBMITTAL: PROVIDE
 SHOP DRAWINGS REVIEWED BY THE DESIGN PROFESSIONAL OF
 RECORD PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS.
 TABLE R301.5, SEC. R311.7.8 AND SEC. R312.1
 FBC-RESIDENTIAL.
  
 B)PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 PROPOSED FACTORY BUILT FIREPLACE SHOWING COMPLIANCE
 WITH SEC. R1004 FBC-RESIDENTIAL AND FACTORY BUILT
 CHIMNEY SHOWING COMPLIANCE WITH SEC. R1005
 FBC-RESIDENTIAL
 NOTE: ARCHITECT TO REVIEW AND APPROVE IN WRITING PRIOR
 TO SUBMITTAL TO THIS OFFICE.
  
 C) ICYNENE FOAM INSULATION ESR-1826 REPORT SUBMITTED
 STATES ON THE COVER PAGE THAT THIS REPORT IS SUBJECT TO
 RENEWAL ON 02/2018. PROVIDE CURRENT REPORT. SEC.
 107.2.1 CITY AMENDMENTS. SEC. R316 FBC-RESIDENTIAL.
 NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-02-11 Cont ID  
Sent By jgomez Date 2021-02-11 Time 15:50 Rev Time 0.00
Received By jgomez Date 2021-02-11 Time 10:11 Sent To  
Notes
2021-02-11 15:53:37NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 PERMIT #20121151
  
 1- BASED ON THE WINDOW SCHEDULE ON SHEET A7.01 IT LOOKS
 LIKE THE SIZE OF SINGLE HUNG WINDOW SPECIFIED (3'-1" X
 5'-0") SPECIFIED BY THE ARCHITECT DOESN'T COMPLY WITH
 THE MINIMUM CLEAR OPENING REQUIREMENTS OF SEC. R310.2.1
 FBC-RESIDENTIAL. TYPICALLY A 60" HEIGHT IMPACT SINGLE
 HUNG WINDOW DOESN'T PROVIDE THE REQUIRED 24" CLEAR
 HEIGHT OPENING. PROVIDE MANUFACTURER'S CUT SHEETS
 SHOWING THAT THE SPECIFIED 37"X60" SINGLE HUNG WINDOW
 MEETS ALL THE EGRESS REQUIREMENTS, INCLUDING THE CLEAR
 OPENING HEIGHT AND TOTAL CLEAR OPENING OF 5.7 S.F.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 2- PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. R401.4
 FBC-RESIDENTIAL. THIS PROPERTY IS LOCATED IN
 QUESTIONABLE SOILS.
  
 3-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
  
 4-ENERGY CALCULATIONS:
 A)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER'S NAME AND BUILDER'S NAME. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)CEILING TYPE ITEM #10(A) ON PAGE 1 OF 4 IS INCORRECT.
 ACCORDING TO PLANS THE ATTIC IS NOT VENTED. SEE PLANS
 AND REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 C)PROJECT INFORMATION ON PAGE 2 OF 4 SPECIFIES 1 STORY
 BUILDING. THIS IS INCORRECT. THIS IS A TWO STORY
 BUILDING. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D)ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 IS INCORRECT.
 PLANS AND PRODUCT APPROVALS SUBMITTED ARE FOR ASPHALT
 SHINGLES NOT WOOD SHINGLES. SEE PLANS AND REVISE AS
 REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 E)ATTIC INFORMATION SPECIFIED ON PAGE 2 OF 4 IS
 INCORRECT. PLANS DON'T SPECIFY ATTIC VENTILATION. ATTIC
 IS DESIGNED AS UNVENTED. SEE PLANS AND REVISE ALL THE
 ATTIC VENTILATION AS REQUIRED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 F)BUILDER TO SIGN THE ENERGY PERFORMANCE LEVEL (EPL)
 DISPLAY CARD SUBMITTED. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL):
  
 A)WOOD ENTRY DOOR AS SPECIFIED ON PLANS AND DOOR
 SCHEDULE.
  
 B)HARDIE BOARD SIDING AS SPECIFIED ON PLANS.
  
 6-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 7- PLANS SHOW A REAR PATIO WITH A ROOF PITCH OF 3:12.
 DESIGNER OF RECORD TO SPECIFY DOUBLE UNDERLAYMENT AS
 REQUIRED BY SEC. R905.2.2 FBC-RESIDENTIAL.
 NOTE: SAME COMMENT APPLIES TO MAIN ROOF OVERHANG. IT
 ALSO SHOWS A 3:12 PITCH.
  
 8- PROVISO:
 A)HANDRAILS AND GUARDRAILS DEFERRED SUBMITTAL: PROVIDE
 SHOP DRAWINGS REVIEWED BY THE DESIGN PROFESSIONAL OF
 RECORD PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS.
 TABLE R301.5, SEC. R311.7.8 AND SEC. R312.1
 FBC-RESIDENTIAL.
  
 B)PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 PROPOSED FACTORY BUILT FIREPLACE SHOWING COMPLIANCE
 WITH SEC. R1004 FBC-RESIDENTIAL AND FACTORY BUILT
 CHIMNEY SHOWING COMPLIANCE WITH SEC. R1005
 FBC-RESIDENTIAL
 NOTE: ARCHITECT TO REVIEW AND APPROVE IN WRITING PRIOR
 TO SUBMITTAL TO THIS OFFICE.
  
 C) ICYNENE FOAM INSULATION ESR-1826 REPORT SUBMITTED
 STATES ON THE COVER PAGE THAT THIS REPORT IS SUBJECT TO
 RENEWAL ON 02/2018. PROVIDE CURRENT REPORT. SEC.
 107.2.1 CITY AMENDMENTS. SEC. R316 FBC-RESIDENTIAL.
 NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-04-15 Cont ID  
Sent By jleahy Date 2021-04-15 Time 11:14 Rev Time 0.00
Received By jleahy Date 2021-04-15 Time 11:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-02-10 Cont ID  
Sent By jleahy Date 2021-02-10 Time 11:04 Rev Time 0.00
Received By jleahy Date 2021-02-10 Time 10:30 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2021-02-19 Cont ID  
Sent By cthroop Date 2021-02-19 Time 10:09 Rev Time 0.00
Received By cthroop Date 2021-02-19 Time 09:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-04-14 Cont ID  
Sent By dbattles Date 2021-04-14 Time 09:59 Rev Time 0.00
Received By dbattles Date 2021-04-01 Time 12:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-02-19 Cont ID  
Sent By lmarchan Date 2021-02-19 Time 10:51 Rev Time 0.00
Received By lmarchan Date 2021-01-25 Time 07:13 Sent To  
Notes
2021-02-02 07:13:22ROUTED FOR BLDG DIV AUDIT
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-02 Cont ID  
Sent By lmarchan Date 2021-02-02 Time 07:12 Rev Time 0.00
Received By shill Date 2021-01-25 Time 10:36 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2021-04-12 Cont ID  
Sent By jgomez Date 2021-04-12 Time 17:01 Rev Time 0.00
Received By jgomez Date 2021-04-12 Time 17:00 Sent To  
Notes
2021-04-12 17:03:24IMPACT FEE REVIEW STAMP DATED 01/13/2021 FOR 2,046 A/C
 SQUARE FEET. TOTAL DUE $533.19. JG.
  
  
 RECEIPT MU-2021-000868 - $546.52 - PAID
 1/5/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2021-02-13 Cont ID  
Sent By lmarchan Date 2021-01-13 Time 15:22 Rev Time 0.00
Received By shill Date 2021-01-05 Time 16:46 Sent To  
Notes
2021-02-13 15:05:47PROJECT NEEDS TO PASS BUILDING BEFORE IMPACT FEES CAN
 PASS REVIEW
 BUILDING PLANS EXAMINER NEEDS TO EVALUATE WHAT WAS
 REVIEWED BY IMPACT FEES AND THEN PASS OR FAIL THIS
 REVIEW
  
  
2021-01-13 10:19:16RECEIPT MU-2021-000868 - $546.52 - PAID
2021-01-05 16:46:481/5/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-12-28 Cont ID  
Sent By shill Date 2020-12-28 Time 07:11 Rev Time 0.00
Received By shill Date 2020-12-28 Time 07:11 Sent To  
Notes
2020-12-28 07:11:40PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-02-09 Cont ID  
Sent By medwards Date 2021-02-09 Time 07:41 Rev Time 0.00
Received By medwards Date 2021-02-09 Time 07:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-02-19 Cont ID  
Sent By cthroop Date 2021-02-19 Time 10:09 Rev Time 0.00
Received By cthroop Date 2021-02-19 Time 09:29 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2021-04-14 Cont ID  
Sent By dbattles Date 2021-04-14 Time 09:58 Rev Time 0.00
Received By dbattles Date 2021-04-13 Time 13:48 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2021-01-25 Cont ID  
Sent By rgathrig Date 2021-01-25 Time 15:32 Rev Time 0.00
Received By rgathrig Date 2021-01-25 Time 15:30 Sent To  
Notes
2021-01-25 15:36:14PRIVATE PROVIDER REVIEW FAILED.
  
 THIS REVIEW WAS FOR THE NTICE TO BUILDING OFFICIAL,
 INSURANCE, AND QUALIFICATIONS FOR PRIVATE PROVIDER,
 INSPECTORS AND PLAN REVIEWERS ONLY
  
 COMPLIANT PLAN REVIEW AFFIDAVITS MUST BE SUBMITTED
 AFTER PLAN REVIEW AUDIT IS COMPLETE
  
 PLANS CAN MOVE ON SO FBC PLAN AUDIT CAN START
  
 RICHARD GATHRIGHT
 ASSISTANT BUILDING OFFICIAL
 561 805 6679
2021-01-05 12:49:16CALCULATED VALUE BASED ON ICC BUILDING VALUATION
 TABLES,
 2 STORY RESIDENTIAL. TYPE IIIB CONSTRUCTION.
 UNDER AIR - 2045SF X $136.62 = $279,388.00
 NO GARAGE
 UTILITY - 209SF X $60.42 = $ 12,628.00
 TOTAL CALCULATED VALUE - $292,016.00
 CT

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2021-02-11 Cont ID  
Sent By jgomez Date 2021-02-11 Time 15:47 Rev Time 0.00
Received By jgomez Date 2021-02-11 Time 15:46 Sent To  
Notes
2021-02-11 15:48:10OWENS CORNING ASPHALT SHINGLES FL10674-R15

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-04-15 Cont ID  
Sent By jgomez Date 2021-04-15 Time 10:46 Rev Time 0.00
Received By jgomez Date 2021-04-15 Time 10:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-04-15 Cont ID  
Sent By jgomez Date 2021-04-15 Time 08:58 Rev Time 0.00
Received By jgomez Date 2021-04-15 Time 08:51 Sent To  
Notes
2021-04-15 08:59:43SIGNATURE REVIEW COMMENTS.
  
 1- WAITING ON SHEET E-1 WITH ENGINEER'S DIGITAL
 SIGNATURE.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-04-12 Cont ID  
Sent By jgomez Date 2021-04-12 Time 18:14 Rev Time 0.00
Received By jgomez Date 2021-04-12 Time 18:05 Sent To  
Notes
2021-04-12 17:51:23SIGNATURE REVIEW COMMENTS.
 1- SOIL TEST REPORT NEED TO HAVE THE ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471
 F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
 PLEASE UPLOAD TO PROJECTDOX SOIL TEST REPORT WITH
 ENGINEER'S DIGITAL SIGNATURE OR PROVIDE HARD COPY OF
 SOIL TEST REPORT L WITH ENGINEER'S ORIGINAL SEAL AND
 SIGNATURE.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  
 2- PREVIOUS COMMENT REGARDING SHEET E-1: PLEASE UPLOAD
 DRAWING WITH THE ENGINEER'S DIGITAL SIGNATURE IN THE
 SIGNATURE FOLDER.
  
 SHEET E-1 HAS NOT BEEN DIGITALLY SIGNED. PLEASE HAVE
 THE DESIGNER DIGITALLY SIGN AND SEAL THIS SHEET AND
 SUBMIT ELECTRONICALLY OR YOU MAY BRING A COPY OF THE
 ORIGINAL SIGNED AND SEALED PAPER COPY TO THE OFFICE.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-02-09 Cont ID  
Sent By medwards Date 2021-02-09 Time 07:54 Rev Time 0.00
Received By medwards Date 2021-02-09 Time 07:53 Sent To  
Notes
2021-02-10 14:12:29ARCHITECT'S AND STRUCTURAL ENGINEER'S DIGITAL
 SIGNATURES ARE OK. JG.
  
  
2021-02-09 07:56:06SHEET E-1 HAS NOT BEEN DIGITALLY SIGNED. PLEASE HAVE
 THE DESIGNER DIGITALLY SIGN AND SEAL THIS SHEET AND
 SUBMIT ELECTRONICALLY OR YOU MAY BRING A COPY OF THE
 ORIGINAL SIGNED AND SEALED PAPER COPY TO THE OFFICE.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2021-01-25 Cont ID  
Sent By kalexand Date 2021-01-25 Time 11:28 Rev Time 0.00
Received By kalexand Date 2021-01-25 Time 11:28 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved