Plan Review Details - Permit 20121118
Plan Review Stops For Permit 20121118
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-04-24 Cont ID  
Sent By cthroop Date 2021-04-24 Time 08:50 Rev Time 0.00
Received By cthroop Date 2021-04-24 Time 08:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-02-26 Cont ID  
Sent By cthroop Date 2021-02-26 Time 07:23 Rev Time 0.00
Received By cthroop Date 2021-02-26 Time 07:17 Sent To  
Notes
2021-02-26 07:27:01PLAN REVIEW / BUILDING / GENERATOR
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: SURVEY
  
 1. R303.5.1 INTAKE OPENINGS: MECHANICAL AND GRAVITY
 OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS
 THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS
 CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS,
 STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-02-26 Cont ID  
Sent By cthroop Date 2021-02-26 Time 07:16 Rev Time 0.00
Received By cthroop Date 2021-02-25 Time 16:53 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-04-20 Cont ID  
Sent By abelisle Date 2021-04-20 Time 20:27 Rev Time 0.00
Received By abelisle Date 2021-04-20 Time 20:27 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-02-26 Cont ID  
Sent By cthroop Date 2021-02-26 Time 07:27 Rev Time 0.00
Received By cthroop Date 2021-02-25 Time 16:53 Sent To  
Notes
2021-02-26 07:34:38PLAN REVIEW GENERATOR / FUEL GAS
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: SUBMIT GAS PERMIT
  
 PROVIDE THE FOLLOWING:
  
 1) GAS ISOMETRIC DRAWING:
 1A) PROVIDE AN ISO DRAWING SHOWING THE ENTIRE SYSTEM
 INCLUDING ALL BRANCH PIPES FROM THE METER TO THE MOST
 REMOTE OUTLET. THE BTUH LOAD OF EACH EXISTING APPLIANCE
 AND THE LOCATIONS OF REGULATORS SHALL BE INDICATED ON
 THE DRAWING- SECTIONS G2412.3 & G2412.4 FBC RES.
 NOTE: YOU MAY PROVIDE THE EXISTING LOAD AS ONE
 CALCULATION ON THE GAS RISER
  
 1B) PROVIDE THE TOTAL DEVELOPED LENGTH OF THE SYSTEM
 FROM THE METER TO THE MOST REMOTE OUTLET, AND BRANCH
 LENGTH SIZES- SECTIONS G2413.4.1, G2413.4.2 &
 G2413.4.3.
 1B) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE
 OUTLET OF THE REGULATOR- SECTION G2421.1
 1C) PROVIDE THE BTUH LOAD OF THE GENERATOR. G2413.2 FBC
 RES.
 1D) PROVIDE PIPE SIZING TABLES. G2413.4
 2) SUBMIT SPECS FOR THE LOW PRESSURE REGULATOR AT THE
 GENERATOR WITH MARKUPS TO INDICATE WHICH MODEL TO BE
 INSTALLED, INLET AND OUTLET PRESSURES, AND ORIFICE
 SIZE- SECTION G2421.1.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-24 Cont ID  
Sent By cthroop Date 2021-04-24 Time 08:50 Rev Time 0.00
Received By cthroop Date 2021-04-07 Time 15:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-03-09 Cont ID  
Sent By shill Date 2021-03-09 Time 11:44 Rev Time 0.00
Received By shill Date 2021-02-19 Time 16:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2021-04-22 Cont ID  
Sent By tklarge Date 2021-04-22 Time 15:06 Rev Time 0.00
Received By tklarge Date 2021-04-22 Time 15:02 Sent To  
Notes
2021-04-22 15:08:13NO PLUMBING INVOLVED.

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-02-26 Cont ID  
Sent By cthroop Date 2021-02-26 Time 07:34 Rev Time 0.00
Received By cthroop Date 2021-02-25 Time 16:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-04-24 Cont ID  
Sent By cthroop Date 2021-04-24 Time 08:50 Rev Time 0.00
Received By cthroop Date 2021-04-24 Time 08:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-02-26 Cont ID  
Sent By cthroop Date 2021-02-26 Time 07:17 Rev Time 0.00
Received By cthroop Date 2021-02-26 Time 07:17 Sent To  
Notes
2021-02-26 07:19:34PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2014 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: PRE-CAST GENERATOR PAD.
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2021-04-21 Cont ID  
Sent By rthermid Date 2021-04-21 Time   Rev Time 0.00
Received By rthermid Date 2021-04-21 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-03-05 Cont ID  
Sent By rthermid Date 2021-03-05 Time   Rev Time  
Received By rthermid Date 2021-03-05 Time   Sent To I
Notes
2021-03-05 11:06:03ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 3/5/2021
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THE PROPOSED GENERATOR MUST BE LOCATED A MINIMUM OF
 10 FEET FROM ANY DOOR AND WINDOW OPENINGS.
 2. PROVIDE THE CORRECT SETBACK DIMENSIONS TO THE SIDE
 PROPERTY LINE - SURVEY INDICATES 49 FEET.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN
 INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
  
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved