Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-01-25 Cont ID  
Sent By rmcdouga Date 2021-01-25 Time 08:09 Rev Time 0.00
Received By rmcdouga Date 2021-01-25 Time 08:09 Sent To  
Notes
2021-01-25 08:11:39THE EXISTING BABY FENCE IS TO REMAIN AS THE SWIMMING
 POOL BARRIER. THE NEW FENCING IS NOT THE SWIMMING POOL
 BARRIER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-01-05 Cont ID  
Sent By rmcdouga Date 2021-01-05 Time 11:38 Rev Time 0.00
Received By rmcdouga Date 2021-01-05 Time 10:18 Sent To  
Notes
2021-01-05 10:54:59PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE SURVEY SHOWS AN EXISTING MESH BARRIER AROUND THE
 SWIMMING POOL. IT IS NOT CLEAR WHETHER THE MESH BABY
 FENCE WILL REMAIN AS THE POOL BARRIER OR IF THE
 PROPOSED FENCING IS INTENDED TO REPLACE IT. PLEASE
 CLARIFY. FBC 107
  
 2) THE PROPOSED FENCE DOES NOT MEET THE REQUIREMENTS OF
 A SWIMMING POOL BARRIER. THE FOLLOWING SECTIONS WILL
 NEED TO BE ADDRESSED.
 A) FBC-R4501.17.1.8
 ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND
 SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS
 R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED
 WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL
 SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED
 NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE
 GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON
 EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE
 REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY
 OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE
 ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM
 THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING
 GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457
 MM) OF THE RELEASE MECHANISM.
  
 B) FBC-R4501.17.1.2
 THE BARRIER MAY NOT HAVE ANY GAPS, OPENINGS,
 INDENTATIONS, PROTRUSIONS, OR STRUCTURAL COMPONENTS
 THAT COULD ALLOW A YOUNG CHILD TO CRAWL UNDER, SQUEEZE
 THROUGH, OR CLIMB OVER THE BARRIER AS HEREIN DESCRIBED
 BELOW. ONE END OF A REMOVABLE CHILD BARRIER SHALL NOT
 BE REMOVABLE WITHOUT THE AID OF TOOLS. OPENINGS IN ANY
 BARRIER SHALL NOT ALLOW PASSAGE OF A 4-INCH-DIAMETER
 (102 MM) SPHERE.
  
 C) FBC-R4501.17.1.9
 WHERE A WALL OF A DWELLING SERVES AS PART OF THE
 BARRIER, ONE OF THE FOLLOWING SHALL APPLY:
  
 1. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM
 THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT
 ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND
 PRESSURE RATING OF 85 DBA AT 10 FEET (3048 MM). ANY
 DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES
 (1372 MM) ABOVE THE THRESHOLD OF THE ACCESS. SEPARATE
 ALARMS ARE NOT REQUIRED FOR EACH DOOR OR WINDOW IF
 SENSORS WIRED TO A CENTRAL ALARM SOUND WHEN CONTACT IS
 BROKEN AT ANY OPENING.
 EXCEPTIONS:
 1.SCREENED OR PROTECTED WINDOWS HAVING A BOTTOM SILL
 HEIGHT OF 48 INCHES (1219 MM) OR MORE MEASURED FROM THE
 INTERIOR FINISHED FLOOR AT THE POOL ACCESS LEVEL.
 2.WINDOWS FACING THE POOL ON FLOOR ABOVE THE FIRST
 STORY.
 3.SCREENED OR PROTECTED PASS-THROUGH KITCHEN WINDOWS 42
 INCHES (1067 MM) OR HIGHER WITH A COUNTER BENEATH.
  
 2.ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO
 THE POOL MUST BE EQUIPPED WITH A SELF-CLOSING,
 SELF-LATCHING DEVICE WITH POSITIVE MECHANICAL
 LATCHING/LOCKING INSTALLED A MINIMUM OF 54 INCHES (1372
 MM) ABOVE THE THRESHOLD, WHICH IS APPROVED BY THE
 AUTHORITY HAVING JURISDICTION.
  
 3.A SWIMMING POOL ALARM THAT, WHEN PLACED IN A POOL,
 SOUNDS AN ALARM UPON DETECTION OF AN ACCIDENTAL OR
 UNAUTHORIZED ENTRANCE INTO THE WATER. SUCH POOL ALARM
 MUST MEET AND BE INDEPENDENTLY CERTIFIED TO ASTM
 STANDARD F2208, TITLED "STANDARD SAFETY SPECIFICATION
 FOR RESIDENTIAL POOL ALARMS," WHICH INCLUDES SURFACE
 MOTION, PRESSURE, SONAR, LASER, AND INFRARED ALARMS.
 FOR PURPOSES OF THIS PARAGRAPH, THE TERM "SWIMMING POOL
 ALARM" DOES NOT INCLUDE ANY SWIMMING PROTECTION ALARM
 DEVICE DESIGNED FOR INDIVIDUAL USE, SUCH AS AN ALARM
 ATTACHED TO A CHILD THAT SOUNDS WHEN THE CHILD EXCEEDS
 A CERTAIN DISTANCE OR BECOMES SUBMERGED IN WATER.
  
 3) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2021-02-02 Cont ID  
Sent By fmittner Date 2021-02-02 Time 11:20 Rev Time 0.00
Received By fmittner Date 2021-02-02 Time 11:20 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-12-30 Cont ID  
Sent By fmittner Date 2020-12-30 Time 15:56 Rev Time 0.00
Received By fmittner Date 2020-12-30 Time 15:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-02-04 Cont ID  
Sent By cpuell Date 2021-02-04 Time 12:44 Rev Time 0.00
Received By cpuell Date 2021-01-21 Time 10:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-05 Cont ID  
Sent By rmcdouga Date 2021-01-05 Time 11:40 Rev Time 0.00
Received By rmcdouga Date 2020-12-23 Time 09:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2021-01-25 Cont ID  
Sent By rmcdouga Date 2021-01-25 Time 08:09 Rev Time 0.00
Received By rmcdouga Date 2021-01-25 Time 08:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-01-05 Cont ID  
Sent By rmcdouga Date 2021-01-05 Time 11:38 Rev Time 0.00
Received By rmcdouga Date 2021-01-05 Time 10:18 Sent To  
Notes
2021-01-05 11:39:42THE TWO FENCE DRAWINGS FROM THE ENGINEERS HAVE NOT BEEN
 DIGITALLY SIGNED. ELECTRONICALLY SUBMITTED DRAWINGS ARE
 REQUIRED TO HAVE THE ENGINEER'S DIGITAL SIGNATURE ON
 THEM. YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND
 SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC
 PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE
 CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT
 TO BE VERIFIED. THE ENGINEER'S ORIGINAL HANDWRITTEN
 SIGNATURE AND SEAL IS REQUIRED TO BE ON THE DRAWINGS.
 NO PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE
 ACCEPTABLE. FS 471 & 61G15

Review Stop Z ZONING
Rev No 2 Status P Date 2021-02-02 Cont ID  
Sent By fmittner Date 2021-02-02 Time 11:21 Rev Time 0.00
Received By fmittner Date 2021-02-02 Time 11:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-12-30 Cont ID  
Sent By fmittner Date 2020-12-30 Time 15:56 Rev Time 0.00
Received By fmittner Date 2020-12-30 Time 15:56 Sent To  
Notes
2020-12-30 15:57:14FOR FENCE AND GATES ONLY