Plan Review Stops For Permit 20121077 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-01-20 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-01-20 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-01-20 |
Time |
12:21 |
Sent To |
|
|
Notes |
2021-01-20 12:22:18 | BACK UNIT HAS A LEGAL ADDRESS OF 839 4TH ST. UPDATED | | PERMIT ADDRESS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2023-07-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-07-21 |
Time |
18:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-07-21 |
Time |
17:02 |
Sent To |
|
|
Notes |
2023-07-21 18:12:25 | NEW SINGLE FAMILY RESIDENCE(R3) SEVEN BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT #20121077 | | 839 4TH ST | | | | ****NOTE: | | ACCORDING TO THE DEPARTMENT OF BUSINESS & PROFESSIONAL | | REGULATION, THE CONTRACTOR'S LICENSE IS SUSPENDED. | | CONTRACTOR TO UPDATE LICENSE STATUS WITH DBPR PRIOR TO | | OBTAINING THE PERMIT OR PROVIDE CHANGE OF CONTRACTOR | | FORM AND A NEW PERMIT APPLICATION. | | | | PROVISO NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY (EXCEPT FOR | | PRODUCT APPROVALS DEFERRED SUBMITTAL). | | | | ***IMPORTANT | | ****CONTRACTOR TO ADVICE IF PROVISO OPTION IS PREFERRED | | AT THIS TIME OR IF RE-SUBMITTING REQUIRED INFORMATION | | BEFORE PERMIT ISSUANCE. | | | | | | 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | A)OK. ROOF SHINGLES FL31588-R2. | | | | PREVIOUS COMMENT: | | D)HARDIE BOARD SIDING. | | FLORIDA PRODUCT APPROVAL NUMBER UPLOADED TO PROJECTDOX | | DOESN'T MATCH FLORIDA PRODUCT APPROVAL NUMBER NAMED IN | | PROJECTDOX SUPPORTING DOCUMENTS. ONE OF THEM IS | | FL13223-R7 AND THE OTHER ONE IS FL13192.2. REVISE AS | | REQUIRED TO MATCH. | | NOTE: WHEN RESUBMITTING PLEASE UPLOAD THE FLORIDA | | PRODUCT APPROVAL COVER PAGE AND INSTALLATION | | INSTRUCTION ON THE SAME FILE. DON'T SPLIT THEM INTO TWO | | SEPARATE FILES. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2023-03-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-03-03 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-03-03 |
Time |
12:57 |
Sent To |
|
|
Notes |
2023-03-03 14:09:16 | NEW SINGLE FAMILY RESIDENCE(R3)SIXTH BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT #20121077 | | 839 4TH ST | | | | ****NOTE: | | ACCORDING TO THE DEPARTMENT OF BUSINESS & PROFESSIONAL | | REGULATION, THE CONTRACTOR'S LICENSE IS SUSPENDED. | | CONTRACTOR TO UPDATE LICENSE STATUS WITH DBPR PRIOR TO | | OBTAINING THE PERMIT. | | | | | | NOTE: | | ENGINEER OF RECORD TO PAY $4728.72 FEE OF FOUR TIMES | | THE AMOUNT OF THE PROPORTION OF THE PERMIT FEE | | ATTRIBUTED TO PLANS REVIEW (LAST REVIEW AND THIS ONE). | | FLORIDA STATUTE 553.80(2)(B | | | | NOTE: | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW | | | | ORIGINAL COMMENT: | | 3-SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING | | COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | 3-ATTIC ACCESS WAS RELOCATED, BUT BASED ON THE ROOF | | FRAMING PLAN, THE LOCATION OF THE ATTIC ACCESS DOESN'T | | SEEM TO PROVIDE THE HEADROOM CLEARANCE REQUIRED BY SEC. | | R807 FBC-RESIDENTIAL. ATTIC ACCESS IS LOCATED BETWEEN | | TWO GABLE END ROOFS. ALSO, BASED ON SECTION 2 ON SHEET | | S-3, THERE IS A MASONRY WALL BETWEEN THE FRONT PART OF | | THE HOUSE AND THE REAR PART OF THE HOUSE. THEREFORE, | | THERE IS NOT ACCESS TO OTHER ROOF AREAS. EACH ROOF AREA | | NEEDS AN ATTIC ACCESS. REVISE AS REQUIRED. | | | | PREVIOUS COMMENT: | | 3- ATTIC ACCESS WAS NOT REVISED ON THE ROOF FRAMING | | PLAN TO MATCH LOCATIONS SHOWN ON SHEET A-1. | | SEC. R807 FBC-RESIDENTIAL. | | | | RESPONSE: | | A)ROOF FRAMING PLAN ON SHEET S2 SHOWS ATTIC ACCESS BY | | THE KITCHEN AREA BEING BLOCKED BY THE TRUSS GIRDER | | ABOVE. REVISE AS REQUIRED. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | B)BEDROOM #3 ATTIC ACCESS LOCATION SHOWN ON SHEET A1 | | DOESN'T MATCH LOCATION AND ORIENTATION SHOWN ON THE | | ROOF FRAMING PLAN ON SHEET S2. REVISE TO MATCH. SEC. | | 107.2.1 CITY AMENDMENTS. | | | | 6-SECTION 2 ON SHEET S-3 SHOWS A MASONRY WALL BETWEEN | | THE FRONT PART OF THE HOUSE AND THE REAR PART OF THE | | HOUSE. ROOF FRAMING PLAN ON SHEET S-2 DOESN'T SPECIFY | | THE BEAM SUPPORTING THE MASONRY WALL. | | ROOF FRAMING PLAN DOESN'T SHOW HOW THE TWO REAR GABLE | | END ROOFS ARE SUPPORTED AT THE INTERSECTION OF BOTH | | ROOFS. | | FRONT PORCH WOOD BEAM SIZE AND ROOF RAFTERS SIZE | | SPECIFIED ON THE ROOF FRAMING PLAN AND WOOD BEAM | | SPECIFIED ON SECTION 2 ON SHEET S-3 DON'T MATCH. | | SECTION 2 ON SHEET S-3 SHOWS OUT LOOKERS IN THE MIDDLE | | MASONRY WALL. THE OUT LOOKERS ARE ON THE OTHER SIDE OF | | THE SECTION BY THE GABLE END AREA. REVISE/CLARIFY WALL | | SECTION AS REQUIRED. | | SEC. R301.1 FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | D)NEW C1 COLUMN IS NOT SHOWN ON THE FLOOR PLAN ON SHEET | | A-1. | | | | RESPONSE: | | PROPOSED FLOOR PLAN ON SHEET A1 SHOWS NEW COLUMN C1 | | BLOCKING THE HALLWAY LEADING TO BEDROOM #2 AND BEDROOM | | #3. REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | PREVIOUS COMMENT: | | E)BEAM SUPPORTING THE TWO GABLE END TRUSSES IS NOT | | SPECIFIED ON THE | | BEAM SCHEDULE. | | | | RESPONSE: | | REPEAT COMMENT. ROOF FRAMING PLAN DOESN'T SPECIFY THIS | | BEAM. SEE SECTION-1 ON SHEET S3. THE BEAM IN QUESTION | | IS THE CENTER BEAM SUPPORTING THE TWO GABLE END | | TRUSSES. SEC. 107.2.1 CITY AMENDMENTS. | | | | 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | A)OK. ROOF SHINGLES FL31588-R2. | | | | PREVIOUS COMMENT: | | D)HARDIE BOARD SIDING. | | FLORIDA PRODUCT APPROVAL NUMBER UPLOADED TO PROJECTDOX | | DOESN'T MATCH FLORIDA PRODUCT APPROVAL NUMBER NAMED IN | | PROJECTDOX SUPPORTING DOCUMENTS. ONE OF THEM IS | | FL13223-R7 AND THE OTHER ONE IS FL13192.2. REVISE AS | | REQUIRED TO MATCH. | | NOTE: WHEN RESUBMITTING PLEASE UPLOAD THE FLORIDA | | PRODUCT APPROVAL COVER PAGE AND INSTALLATION | | INSTRUCTION ON THE SAME FILE. DON'T SPLIT THEM INTO TWO | | SEPARATE FILES. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | NEW COMMENT: | | 12- ENGINEER'S SELF CERTIFIED DIGITAL SIGNATURE | | 1- REVISED DRAWINGS A1, S1, S2, S3 AND S5 HAVE | | ENGINEER'S SELF-CERTIFIED SIGNATURE. BOARD OF | | ENGINEER'S DON'T ALLOW SELF-CERTIFICATION. A THIRD | | PARTY CERTIFICATION IS REQUIRED. | | FAC 61G15-23.004. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2022-12-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-12-22 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-12-21 |
Time |
16:10 |
Sent To |
|
|
Notes |
2022-12-27 16:46:34 | NEW SINGLE FAMILY RESIDENCE (R3) FIFTH BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT #20121077 | | 839 4TH ST | | | | NOTE: | | ENGINEER OF RECORD TO PAY $4728.72 FEE OF FOUR TIMES | | THE AMOUNT OF THE PROPORTION OF THE PERMIT FEE | | ATTRIBUTED TO PLANS REVIEW (LAST REVIEW AND THIS ONE). | | FLORIDA STATUTE 553.80(2)(B | | | | NOTE: | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW | | | | | | ORIGINAL COMMENT: | | 3-SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING | | COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | 3-ATTIC ACCESS WAS RELOCATED, BUT BASED ON THE ROOF | | FRAMING PLAN, THE LOCATION OF THE ATTIC ACCESS DOESN'T | | SEEM TO PROVIDE THE HEADROOM CLEARANCE REQUIRED BY SEC. | | R807 FBC-RESIDENTIAL. ATTIC ACCESS IS LOCATED BETWEEN | | TWO GABLE END ROOFS. ALSO, BASED ON SECTION 2 ON SHEET | | S-3, THERE IS A MASONRY WALL BETWEEN THE FRONT PART OF | | THE HOUSE AND THE REAR PART OF THE HOUSE. THEREFORE, | | THERE IS NOT ACCESS TO OTHER ROOF AREAS. EACH ROOF AREA | | NEEDS AN ATTIC ACCESS. REVISE AS REQUIRED. | | | | RESPONSE: | | ATTIC ACCESS WAS NOT REVISED ON THE ROOF FRAMING PLAN | | TO MATCH LOCATIONS SHOWN ON SHEET A-1. | | SEC. R807 FBC-RESIDENTIAL. | | | | ORIGINAL COMMENT: | | 6- BEAM SCHEDULE ON SHEET S-2 ONLY SPECIFIES B-1 BEAM. | | IT DOESN'T SPECIFY THE RAKE BEAM SHOWN ON SHEET S-4. | | REVISE AS REQUIRED TO CLARIFY. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | PREVIOUS COMMENT: | | SECTION 2 ON SHEET S-3 SHOWS A MASONRY WALL BETWEEN THE | | FRONT PART OF THE HOUSE AND THE REAR PART OF THE HOUSE. | | ROOF FRAMING PLAN ON SHEET S-2 DOESN'T SPECIFY THE BEAM | | SUPPORTING THE MASONRY WALL. | | ROOF FRAMING PLAN DOESN'T SHOW HOW THE TWO REAR GABLE | | END ROOFS ARE SUPPORTED AT THE INTERSECTION OF BOTH | | ROOFS. | | FRONT PORCH WOOD BEAM SIZE AND ROOF RAFTERS SIZE | | SPECIFIED ON THE ROOF FRAMING PLAN AND WOOD BEAM | | SPECIFIED ON SECTION 2 ON SHEET S-3 DON'T MATCH. | | SECTION 2 ON SHEET S-3 SHOWS OUT LOOKERS IN THE MIDDLE | | MASONRY WALL. THE OUT LOOKERS ARE ON THE OTHER SIDE OF | | THE SECTION BY THE GABLE END AREA. REVISE/CLARIFY WALL | | SECTION AS REQUIRED. | | SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | A)ROOF FRAMING PLAN ON SHEET S2 SHOWS B-1 BEAM | | SUPPORTING THE MASONRY WALL AND RAKE BEAM RB-1. | | FOUNDATION PLAN WAS REVISED SHOWING COLUMN C1 AND | | FOOTING CF-16 IN THE MIDDLE OF THE FLOOR SLAB. ENGINEER | | TO CLARIFY WHY SPECIFYING A CONTINUOUS SPREAD FOOTING | | INSTEAD OF A CONCRETE PAD IF THE LOAD IS THE ECCENTRIC | | LOAD FROM THE COLUMN?. SEC. R301.1 FBC-RESIDENTIAL. | | | | B)FOUNDATION PLANS WAS ALSO REVISED SHOWING NEW C1 | | COLUMNS ON THE PERIMETER WALL BUT THERE IS NOT COLUMN | | SUPPORTING BEAM B-1 ON THE LEFT HAND SIDE. | | | | C) SIZE OF BEAM B-1 SPECIFIED ON SECTION 2 OF SHEET S-3 | | DOESN'T MATCH SIZE SPECIFIED ON THE BEAM SCHEDULE. | | | | D)NEW C1 COLUMN IS NOT SHOWN ON THE FLOOR PLAN ON SHEET | | A-1. | | | | E)BEAM SUPPORTING THE TWO GABLE END TRUSSES IS NOT | | SPECIFIED ON THE | | BEAM SCHEDULE. | | | | F)PORCH WOOD JOIST SIZE SPECIFIED ON SECTION 2 OF SHEET | | S-3 DOESN'T MATCH ROOF FRAMING PLAN. | | | | | | ORIGINAL COMMENT: | | 7- PLANS DON'T PROVIDE SPECIFICATIONS FOR THE ROOF | | SHEATHING. SPECIFY TYPE, THICKNESS AND ROOF SHEATHING | | FASTENING AS REQUIRED BY SEC. R803.2.3.1 | | FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | INFORMATION SHOWN ON THE TYPICAL WALL SECTION ON SHEET | | A-1 DOESN'T MATCH INFORMATION SHOWN ON OTHER PLANS AND | | SECTIONS. REVISE AS REQUIRED TO MATCH TO AVOID MORE | | CONFLICTS/DELAYS. ROOF SHEATHING SPECIFICATIONS DON'T | | MATCH SPECIFICATIONS SHOWN ON SHEET S-5. FOOTING SIZE | | DOESN'T MATCH FOUNDATION PLAN. ATTIC INSULATION DOESN'T | | MATCH. ETC. | | NOTE: ENGINEER TO COORDINATE ALL PLANS, SECTIONS AND | | SPECIFICATIONS TO AVOID MORE CONFLICTS AND DELAYS. | | | | RESPONSE: | | ROOF SHEATHING SPECIFICATIONS DON'T MATCH SECTION | | R803.2.3.1 FBC-RESIDENTIAL AND FIGURE R803.2.3.1 | | FBC-RESIDENTIAL. NEED TO SPECIFY NAILS AT 4" O.C. ON | | ROOF ZONE #3 AND NEED TO SPECIFY RING SHANK NAILS. (OR | | PROVIDE CALCULATIONS SHOWING THAT 10D NAIL MATCHES OR | | EXCEEDS 8D RING SHANK NAILS AS REQUIRED BY SEC. | | R803.2.3.1 FBC-RESIDENTIAL). | | | | ALSO, ROOF SHEATHING SPECIFICATIONS DON'T COMPLY WITH | | GABLE ROOF NAILING REQUIREMENTS OF FIGURE R803.2.3.1 | | FBC-RESIDENTIAL. ROOF ZONE 3 IS 5 FEET NOT 48". | | | | ORIGINAL COMMENT: | | 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR | | STEEL COLUMNS SHOWN ON THE FRONT PORCH. SPECIFY TOP AND | | BOTTOM CONNECTORS AND FURRING DETAILS. | | SEC. R301.1 FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | SECTION 2 ON SHEET S-3 SHOWS STEEL COLUMNS BELOW GRADE. | | THIS INFORMATION DOESN'T MATCH INFORMATION SHOWN ON THE | | FOUNDATION PLAN. FOUNDATION PLAN SHOWS A KNEE WALL. | | ALSO, THERE ARE NO DETAIL/SPECIFICATIONS SHOWING HOW | | THE STEEL COLUMNS AND CONNECTIONS ARE PROTECTED AGAINST | | RUST/DETERIORATION. | | | | RESPONSE: | | SECTION 2 ON SHEET S3 STILL DOESN'T MATCH FOUNDATION | | PLAN. IT DOESN'T SHOW THE KNEE WALL AND IT IS NOT CLEAR | | WHAT IS THE PURPOSE OF THE CONCRETE PEDESTAL. THE | | CONCRETE PEDESTAL IS COVERING THE STEEL COLUMN. WHY?. | | WHAT IS THE PURPOSE OF COVERING THE STEEL COLUMN WITH A | | PEDESTAL. ALSO NO SPECS FOR STEEL COLUMN, PLATE AND | | BOLTS PROTECTION FOR RUST. | | | | 9-OK. | | | | 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | | | A)OK. ROOF SHINGLES FL31588-R2. | | | | PREVIOUS COMMENT: | | D)HARDIE BOARD SIDING. | | FLORIDA PRODUCT APPROVAL NUMBER UPLOADED TO PROJECTDOX | | DOESN'T MATCH FLORIDA PRODUCT APPROVAL NUMBER NAMED IN | | PROJECTDOX SUPPORTING DOCUMENTS. ONE OF THEM IS | | FL13223-R7 AND THE OTHER ONE IS FL13192.2. REVISE AS | | REQUIRED TO MATCH. | | NOTE: WHEN RESUBMITTING PLEASE UPLOAD THE FLORIDA | | PRODUCT APPROVAL COVER PAGE AND INSTALLATION | | INSTRUCTION ON THE SAME FILE. DON'T SPLIT THEM INTO TWO | | SEPARATE FILES. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2022-07-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-12 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-11 |
Time |
17:46 |
Sent To |
|
|
Notes |
2022-07-12 16:52:59 | NEW SINGLE FAMILY RESIDENCE (R3) FOURTH BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT #20121077 | | | | | | NOTE: | | ENGINEER OF RECORD TO PAY $2364.36 FEE OF FOUR TIMES | | THE AMOUNT OF THE PROPORTION OF THE PERMIT FEE | | ATTRIBUTED TO PLANS REVIEW. | | FLORIDA STATUTE 553.80(2)(B | | | | | | | | NOTE: | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW | | | | | | | | ORIGINAL COMMENT: | | 2-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | FOLLOWING: | | R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS. | | SEC. 110.9 CITY AMENDMENTS. | | | | RESPONSE: | | A)DRAINAGE PLAN SHOWS A 6 INCH SWALE IMMEDIATELY | | ADJACENT TO THE EXISTING RESIDENCE #837. THE PROPOSED | | SWALE AFFECTS THE FOUNDATION. ENGINEER OF RECORD TO | | PROVIDE DETAILS SPECIFICATIONS SHOWING HOW PROTECTING | | THE FOOTING AS REQUIRED BY SEC. R401.3 BC-RESIDENTIAL. | | | | B)DRAINAGE PLAN SHOWS A PERMANENT TRENCH AND SILT FENCE | | TO CONTAIN THE SURFACE DRAINAGE. NEED TO APPLY FOR A | | SEPARATE FENCE PERMIT FOR ZONING APPROVAL. SEC. 105.1 | | CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 3-SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING | | COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL. | | | | RESPONSE: | | ATTIC ACCESS WAS RELOCATED, BUT BASED ON THE ROOF | | FRAMING PLAN, THE LOCATION OF THE ATTIC ACCESS DOESN'T | | SEEM TO PROVIDE PROVIDE THE HEADROOM CLEARANCE REQUIRED | | BY SEC. R807 FBC-RESIDENTIAL. ATTIC ACCESS IS LOCATED | | BETWEEN TWO GABLE END ROOFS. ALSO, BASED ON SECTION 2 | | ON SHEET S-3, THERE IS A MASONRY WALL BETWEEN THE FRONT | | PART OF THE HOUSE AND THE REAR PART OF THE HOUSE. | | THEREFORE, THERE IS NOT ACCESS TO OTHER ROOF AREAS. | | EACH ROOF AREA NEEDS AN ATTIC ACCESS. REVISE AS | | REQUIRED. | | | | ORIGINAL COMMENT: | | 6- BEAM SCHEDULE ON SHEET S-2 ONLY SPECIFIES B-1 BEAM. | | IT DOESN'T SPECIFY THE RAKE BEAM SHOWN ON SHEET S-4. | | REVISE AS REQUIRED TO CLARIFY. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | RESPONSE: | | SECTION 2 ON SHEET S-3 SHOWS A MASONRY WALL BETWEEN THE | | FRONT PART OF THE HOUSE AND THE REAR PART OF THE HOUSE. | | ROOF FRAMING PLAN ON SHEET S-2 DOESN'T SPECIFY THE BEAM | | SUPPORTING THE MASONRY WALL. | | ROOF FRAMING PLAN DOESN'T SHOW HOW THE TWO REAR GABLE | | END ROOFS ARE SUPPORTED AT THE INTERSECTION OF BOTH | | ROOFS. | | FRONT PORCH WOOD BEAM SIZE AND ROOF RAFTERS SIZE | | SPECIFIED ON THE ROOF FRAMING PLAN AND WOOD BEAM | | SPECIFIED ON SECTION 2 ON SHEET S-3 DON'T MATCH. | | SECTION 2 ON SHEET S-3 SHOWS OUTLOOKERS IN THE MIDDLE | | MASONRY WALL. THE OUTLOOKERS ARE ON THE OTHER SIDE OF | | THE SECTION BY THE GABLE END AREA. REVISE/CLARIFY WALL | | SECTION AS REQUIRED. | | SEC. R301.1 FBC-RESIDENTIAL. | | | | ORIGINAL COMMENT: | | 7- PLANS DON'T PROVIDE SPECIFICATIONS FOR THE ROOF | | SHEATHING. SPECIFY TYPE, THICKNESS AND ROOF SHEATHING | | FASTENING AS REQUIRED BY SEC. R803.2.3.1 | | FBC-RESIDENTIAL. | | | | RESPONSE: | | INFORMATION SHOWN ON THE TYPICAL WALL SECTION ON SHEET | | A-1 DOESN'T MATCH INFORMATION SHOWN ON OTHER PLANS AND | | SECTIONS. REVISE AS REQUIRED TO MATCH TO AVOID MORE | | CONFLICTS/DELAYS. ROOF SHEATHING SPECIFICATIONS DON'T | | MATCH SPECIFICATIONS SHOWN ON SHEET S-5. FOOTING SIZE | | DOESN'T MATCH FOUNDATION PLAN. ATTIC INSULATION DOESN'T | | MATCH. ETC. | | NOTE: ENGINEER TO COORDINATE ALL PLANS, SECTIONS AND | | SPECIFICATIONS TO AVOID MORE CONFLICTS AND DELAYS. | | | | ORIGINAL COMMENT: | | 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR | | STEEL COLUMNS SHOWN ON THE FRONT PORCH. SPECIFY TOP AND | | BOTTOM CONNECTORS AND FURRING DETAILS. | | SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | SECTION 2 ON SHEET S-3 SHOWS STEEL COLUMNS BELOW GRADE. | | THIS INFORMATION DOESN'T MATCH INFORMATION SHOWN ON THE | | FOUNDATION PLAN. FOUNDATION PLAN SHOWS A KNEE WALL. | | ALSO, THERE ARE NO DETAIL/SPECIFICATIONS SHOWING HOW | | THE STEEL COLUMNS AND CONNECTIONS ARE PROTECTED AGAINST | | RUST/DETERIORATION. | | | | ORIGINAL COMMENT: | | 9- PROVIDE DOORS AND WINDOWS STRUCTURAL BUCK DETAIL. | | NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO | | THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1 | | FBC-RESIDENTIAL. | | | | RESPONSE: | | BUCK DETAIL ON SHEET A1 DOESN'T PROVIDE THE STRUCTURAL | | BUCK SPECIFICATIONS AS REQUESTED AND DOESN'T SEEM TO | | APPLY TO THIS JOB. | | | | 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR | | A)OK. ROOF SHINGLES FL31588-R2. | | | | ORIGINAL COMMENT: | | D)HARDIEBOARD SIDING. INFORMATION SUBMITTED IS NOT A | | PRODUCT APPROVAL. NEED MIAMI DADE NOA OR COMPLETE | | FLORIDA PRODUCT APPROVAL. | | | | RESPONSE: | | FLORIDA PRODUCT APPROVAL NUMBER UPLOADED TO PROJECTDOX | | DOESN'T MATCH FLORIDA PRODUCT APPROVAL NUMBER NAMED IN | | PROJECTDOX SUPPORTING DOCUMENTS. ONE OF THEM IS | | FL13223-R7 AND THE OTHER ONE IS FL13192.2. REVISE AS | | REQUIRED TO MATCH. | | NOTE: WHEN RESUBMITTING PLEASE UPLOAD THE FLORIDA | | PRODUCT APPROVAL COVER PAGE AND INSTALLATION | | INSTRUCTION ON THE SAME FILE. DON'T SPLIT THEM INTO TWO | | SEPARATE FILES. | | | | ORIGINAL COMMENT: | | E) SINGLE HUNG WINDOWS. NEW COMMENT BASED ON REVISED | | PLANS. PROVIDE PRODUCT APPROVAL FOR SINGLE HUNG WINDOW | | SIZE SPECIFIED ON PLANS FO WINDOW A. NEW 72"W X 52"H | | SINGLE HUNG WINDOW. | | | | RESPONSE: | | REPEAT COMMENT. NOA SUBMITTED DOESN'T COVER 72" WIDE | | WINDOW. NEED TO PROVIDE PRODUCT APPROVAL THAT COVERS | | THIS WINDOW SIZE AS SPECIFIED ON PLANS. | | | | F) PROVIDE PRODUCT APPROVAL FOR SHINGLES UNDERLAYMENT | | SPECIFIED ON TYPICAL WALL SECTION ON SHEET A-1. | | | | 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 14- PROVIDE COMPLETE WALL SECTION FROM FOUNDATION | | THROUGH ROOF AS REQUIRED BY SEC. 107.5.3 CITY | | AMENDMENTS. | | | | RESPONSE: | | REVISE NEW TYPICAL WALL SECTION ON SHEET A1: | | A) FOOTING SIZE DOESN'T MATCH SIZE SPECIFIED ON THE | | FOUNDATION PLAN. SEC. 107.2.1 CITY AMENDMENTS. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | C)ROOF SHEATHING NAILING SPECIFICATIONS ARE NOT CLEAR. | | NOTE: SEE SECTION R803.2.3.1 FBC-RESIDENTIAL AND FIGURE | | R803.2.3.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | ROOD SHEATHING SPECIFICATIONS ON TYPICAL WALL SECTION | | AND SPECIFICATIONS ON SHEET S-5 DON'T MATCH. REVISE AS | | REQUIRED TO MATCH. NOTE: SEE SECTION R803.2.3.1 | | FBC-RESIDENTIAL AND FIGURE R803.2.3.1 FBC-RESIDENTIAL. | | | | D) ROOF INSULATION ON TYPICAL WALL SECTION AND | | SPECIFICATIONS ON SHEET S-3 DON'T MATCH. REVISE AS | | REQUIRED TO MATCH. | | | | | | ORIGINAL COMMENT: | | 17- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | CONSTRUCTION OF THE FRONT AND BACK GUARDRAILS SHOWING | | COMPLIANCE WITH SEC. R312.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. DESIGN INFORMATION NEEDS | | TO BE SHOWN ON PLANS BY THE DESIGNER OF RECORD. PRODUCT | | APPROVALS OR SHOP DRAWINGS ARE DEFERRED SUBMITTALS JUST | | TO CONFIRM THE DESIGN INTENT OF THE DESIGN PROFESSIONAL | | OF RECORD. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-10-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-10-21 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-10-21 |
Time |
09:29 |
Sent To |
|
|
Notes |
2021-10-21 15:18:16 | NEW SINGLE FAMILY RESIDENCE (R3) THIRD BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT #20121077 | | | | NOTE: | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | NECESSARY, IN ORDER TO ENFORRCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW | | | | ORIGINAL COMMENT: | | 2-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | FOLLOWING: | | R401.3 FBC-RESIDENTIAL. | | SEC. 107.2.5 CITY AMENDMENTS. | | SEC. 110.9 CITY AMENDMENTS. | | | | RESPONSE: | | A) PROVIDE DIMENSIONS ON TYPICAL WET SWALE CROSS | | SECTION. SPECIFY DEPTH OF SWALE, DISTANCE FROM | | BUILDING, ETC. SEC. 1072.1 CITY AMENDMENTS. | | B) PROVIDE TRENCH WITH GRAVEL DETAIL #1 AS SHOWN ON | | DRAINAGE PLAN ALONG PERIMETER OF LOT. DETAIL WAS NOT | | GIVEN. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | 3-SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING | | COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL. | | | | RESPONSE: | | BASED ON THE ROOF FRAMING PLAN, THE LOCATION OF THE | | ATTIC ACCESS DOESN'T PROVIDE THE CLEARANCE REQUIRED BY | | SEC. R807 FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | ORIGINAL COMMENT: | | 6- BEAM SCHEDULE ON SHEET S-2 ONLY SPECIFIES B-1 BEAM. | | IT DOESN'T SPECIFY THE RAKE BEAM SHOWN ON SHEET S-4. | | REVISE AS REQUIRED TO CLARIFY. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | RESPONSE: | | REVISED ROOF FRAMING PLAN IS INCOMPLETE. IT IS MISSING | | THE ROOF AT THE ENTRY PORCH. THERE IS NOT CORRELATION | | BETWEEN THE WOOD BEAM SCHEDULES AND THE ROOF FRAMING | | PLAN. THERE IS NOT TRUSS CONNECTOR SCHEDULE. THERE IS | | NOT INFORMATION ABOUT THE GABLE END BEAMS. ARE THESE | | CONCRETE RAKED BEAMS?. THERE IS NOT INFORMATION FOR | | PORCH BEAMS, COLUMNS, ALL STRUCTURAL CONNECTORS OF ALL | | STRUCTURAL MEMBERS (ROOF TRUSSES, BEAMS AND COLUMNS). | | NEW ROOF FRAMING PLAN SHOWS TWO GABLE END ROOFS | | INTERSECTING ON THE REAR OF THE HOUSE. SEE REAR | | ELEVATION ON SHEET A-2. NEED TO PROVIDE DETAILS AND | | SPECIFICATIONS FOR CRICKET CONSTRUCTION IN THIS AREA. | | NEED TO PROVIDE COMPLETE ROOF FRAMING PLAN WITH ALL THE | | INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | | ORIGINAL COMMENT: | | 7- PLANS DON'T PROVIDE SPECIFICATIONS FOR THE ROOF | | SHEATHING. SPECIFY TYPE, THICKNESS AND ROOF SHEATHING | | FASTENING AS REQUIRED BY SEC. R803.2.3.1 | | FBC-RESIDENTIAL. | | | | RESPONSE: | | ENGINEER'S RESPONSE SAID SEE REVISED SHEET S-3. | | SECTIONS 1 AND 2 ON SHEET S-3 DON'T MATCH REVISED ROOF | | FRAMING PLAN. SEE NEW ROOF PROFILE. THERE ARE NO | | SPECIFICATIONS FOR THE ROOF SHEATHING. PORCH | | CONSTRUCTION DOESN'T MATCH PORCH SHOWN ON THE EXTERIOR | | ELEVATIONS AND NEEDS MORE INFORMATION. FRAMING AT GABLE | | ENDS IS NOT CLEAR. HOW THE GABLE END IS GOING TO BE | | BUILT. SPECIFY ALL GABLE FRAMING MEMBERS AND | | CONNECTORS. NEED COLUMNS CONNECTOR AT TOP AND BOTTOM, | | WOOD BEAM SHOWN DON'T REFLECT (2)2X12 WOOD BEAM. DETAIL | | SHOWS FOUR 2X12'S. SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: ENGINEER OF RECORD TO COORDINATE ALL PLANS, | | DETAILS AND SPECIFICATIONS TO AVOID MORE CONFLICTS AND | | DELAYS. | | | | ORIGINAL COMMENT: | | 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR | | STEEL COLUMNS SHOWN ON THE FRONT PORCH. SPECIFY TOP AND | | BOTTOM CONNECTORS AND FURRING DETAILS. | | SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. SEE RESPONSE TO ITEM #6 ABOVE. | | | | ORIGINAL COMMENT: | | 9- PROVIDE DOORS AND WINDOWS STRUCTURAL BUCK DETAIL. | | NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO | | THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1 | | FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. | | | | 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR | | | | ORIGINAL COMMENT: | | A)ROOF MATERIAL FOR PITCHED ROOF AS SPECIFIED ON PLANS. | | | | RESPONSE: | | NOA 19-0617.05 SUBMITTED NOW IS NOT FOR SHINGLES. WRONG | | NOA AGAIN. | | | | ORIGINAL COMMENT: | | D)HARDIEBOARD SIDING. INFORMATION SUBMITTED IS NOT A | | PRODUCT APPROVAL. NEED MIAMI DADE NOA OR COMPLETE | | FLORIDA PRODUCT APPROVAL. | | | | RESPONSE: | | NOA 20-0730.05 SUBMITTED IS FOR INSTALLATION TO WOOD | | FRAMED BUILDINGS. THIS HOUSE IS CONCRETE BLOCK. NEED | | PRODUCT APPROVAL FOR INSTALLATION ON CONCRETE BLOCK | | CONSTRUCTION. | | | | E) SINGLE HUNG WINDOWS. NEW COMMENT BASED ON REVISED | | PLANS. PROVIDE PRODUCT APPROVAL FOR SINGLE HUNG WINDOW | | SIZE SPECIFIED ON PLANS FO WINDOW A. NEW 72"W X 52"H | | SINGLE HUNG WINDOW. | | | | 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS | | (INCLUDING THE HARDIEBOARD SIDING) AS REQUIRED BY SEC. | | 107.3.4.1 CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 14- PROVIDE COMPLETE WALL SECTION FROM FOUNDATION | | THROUGH ROOF AS REQUIRED BY SEC. 107.5.3 CITY | | AMENDMENTS. | | | | RESPONSE: | | REVISE NEW TYPICAL WALL SECTION ON SHEET A1: | | A) FOOTING SIZE DOESN'T MATCH SIZE SPECIFIED ON THE | | FOUNDATION PLAN. SEC. 107.2.1 CITY AMENDMENTS. | | | | B)ROOFING COVER AND UNDERLAYMENT SPECIFIED IS NOT | | CLEAR. THESE SPECIFICATIONS ARE NOT FOR SHINGLES. | | COORDINATE WITH PRODUCT APPROVAL COMMENT ABOVE. SEC. | | 107.2.1 CITY AMENDMENTS. | | | | C)ROOF SHEATHING NAILING SPECIFICATIONS ARE NOT CLEAR. | | COORDINATE WITH ITEM #7 ABOVE. NOTE: SEE TABLE | | R803.2.3.1 FBC-RESIDENTIAL FOR MINIMUM ROOF SHEATHING | | ATTACHMENT. | | | | NEW COMMENTS: | | 16- FOUNDATION PLAN ON SHEET S1: | | A)MISSING THE FOOTING FOR THE FRONT AND REAR PORCHES. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | B)FOUNDATION PLANS DOESN'T SHOW THE FOOTINGS SHOWN ON | | THE FOOTING SCHEDULE. SEC. 107.2.1 CITY AMENDMENTS. | | | | C) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | CONSTRUCTION OF FRONT AND REAR STAIRWAYS SHOWING | | COMPLIANCE WITH SEC. R311.7 FBC-RESIDENTIAL. | | | | 17- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | CONSTRUCTION OF THE FRONT AND BACK GUARDRAILS SHOWING | | COMPLIANCE WITH SEC. R312.1 FBC-RESIDENTIAL. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-08-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-08-17 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-08-17 |
Time |
10:40 |
Sent To |
|
|
Notes |
2021-08-17 13:10:40 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT #20121077 | | | | NOTE: | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW | | | | | | | | ORIGINAL COMMENT: | | 1-ENERGY CALCULATIONS SUBMITTED: | | A) THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR | | OTHER AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER | | SHALL CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH | | THE CODE, AS PER SECTION 553.907, FLORIDA STATUTES, | | PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | RENOVATION AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | CONSERVATION. | | | | RESPONSE: | | REPEAT COMMENT. | | | | B) PROVIDE THE NAME OF THE PERSON DOING THE | | CALCULATIONS AS REQUIRED BY SEC. R405.4.2.1 FBC-ENERGY | | CONSERVATION. | | | | RESPONSE: | | REPEAT COMMENT. | | | | C)PROVIDE CORRECT AND COMPLETE INFORMATION ON TOP OF | | FORM. CORRECT ADDRESS IS 839 4TH STREET NOT 837 4TH | | STREET. PROVIDE OWNER'S NAME. PROVIDE BUILDER'S NAME. | | PERMITTING OFFICE IS WEST PALM BEACH NOT PALM BEACH. | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | RESPONSE: | | REPEAT COMMENT. | | | | D)ITEM #8(A) ON PAGE 1 OF 4 SPECIFIES R-5 SLAB-ON-GRADE | | EDGE INSULATION. PLANS DON'T SPECIFY ANY SLAB EDGE | | INSULATION. REVISE AS REQUIRED TO MATCH. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | RESPONSE: | | REPEAT COMMENT. | | | | E)ITEM #9(A) ON PAGE 1 OF 4 SPECIFIES R-4.5 EXTERIOR | | INSULATION ON CONCRETE BLOCK. PLANS DON'T SPECIFY | | EXTERIOR INSULATION ON THE CONCRETE BLOCK. THE | | INSULATION IS ON THE INTERIOR SIDE. SEE PLANS AND | | REVISE AS REQUIRED TO MATCH, INCLUDING R-VALUE | | SPECIFIED. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | RESPONSE: | | REPEAT COMMENT. | | | | F)ITEM #10(A) ON PAGE 1 OF 4 SPECIFIES R-19 UNDER ATTIC | | INSULATION. THIS DOESN'T MATCH PLANS. SEE PLANS AND | | REVISE AS REQUIRED TO MATCH, INCLUDING. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | RESPONSE: | | REPEAT COMMENT. | | | | G)ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 NEEDS TO BE | | COORDINATED WITH PLANS. PLANS ARE NOT CLEAR ON WHAT | | ROOFING MATERIAL IS GOING TO BE INSTALLED BUT IT | | DOESN'T SPECIFY FLAT TILE OR SLATE. COORDINATE WITH | | ENGINEER PLANS AND REVISE AS REQUIRED TO MATCH. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | RESPONSE: | | REPEAT COMMENT. | | | | H)REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 4. PLANS | | DON'T SHOW ANY 1/300 VENT RATIO. TYPICALLY, THE RATIO | | IS 1/150 NOT 1/300. SEC. R806.2 FBC-RESIDENTIAL. OR | | PERSON PREPARING THE ENERGY CALCULATIONS TO PROVIDE | | COMPLETE DETAILS/SPECIFICATIONS SHOWING COMPLIANCE WITH | | THE 1/300 RATIO AS REQUIRED BY THE EXCEPTION ON SEC. | | R806.2. NOTE: ENGINEER OF RECORD NEEDS TO | | REVIEW/APPROVE THEM PRIOR TO SUBMITTAL. | | | | RESPONSE: | | REPEAT COMMENT. | | | | I)DOOR TYPE INFORMATION SPECIFIED ON PAGE 3 OF 4 IS | | INCORRECT. ACCORDING TO PLANS AND PRODUCT APPROVALS | | SUBMITTED THE ENTRY DOOR AND THE BEDROOM #3 DOORS ARE | | ALUMINUM DOORS WITH GLAZING. GLASS IN THESE DOORS NEED | | TO BE INCLUDED ON THE GLASS CALCULATIONS AS REQUIRED BY | | SEC. R405.5.3.1 AND SEC. R405.5.3.3 FBC-ENERGY | | CONSERVATION. REVISE AS REQUIRED. | | | | RESPONSE: | | REPEAT COMMENT. | | | | J)WINDOWS INFORMATION SPECIFIED ON 3 OF 4 DOESN'T MATCH | | PLANS. REVISE THE WINDOW AREA AND WINDOW OVERHANG DEPTH | | AND SEPARATION TO MATCH PLANS. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | RESPONSE: | | REPEAT COMMENT. | | | | NEW COMMENT: | | K)FLOOR PLAN WAS REVISED. NEW ENERGY CALCULATIONS NEED | | TO BE DONE BASED ON THE NEW FLOOR PLAN. COORDINATE ALL | | THE INFORMATION ACCORDINGLY. | | | | ORIGINAL COMMENT: | | 2-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | FOLLOWING: | | R401.3 FBC-RESIDENTIAL. | | SEC. 107.2.5 CITY AMENDMENTS. | | SEC. 110.9 CITY AMENDMENTS. | | | | RESPONSE: | | REPEAT COMMENT. | | | | ORIGINAL COMMENT: | | 3-SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING | | COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. | | | | ORIGINAL COMMENT: | | 4-PLANS SUBMITTED DON'T SPECIFY WHAT IS THE ROOFING | | MATERIAL. IS IT SHINGLES?, TILE?. IF USING SHINGLES , | | THEN A ROOF PITCH OF 2:12 TO LESS THAN 4:12 REQUIRES | | TWO LAYERS OF UNDERLAYMENT AS REQUIRED BY SEC. R905.2.2 | | FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS ON PLANS FOR | | THE TWO LAYERS OF UNDERLAYMENT. ALSO, PROVIDE | | SPECIFICATIONS FOR THE FLAT ROOF. | | | | RESPONSE: | | PLANS SUBMITTED STILL DON'T SPECIFY THE ROOF PITCH. | | SPECIFY THE ROOF SLOPE ON ALL ROOF AREAS SHOWN ON THE | | REVISED PLANS. | | | | | | 5- OK. NO FLAT ROOFS ON REVISED PLANS. | | | | ORIGINAL COMMENT: | | 6- BEAM SCHEDULE ON SHEET S-2 ONLY SPECIFIES B-1 BEAM. | | IT DOESN'T SPECIFY THE RAKE BEAM SHOWN ON SHEET S-4. | | REVISE AS REQUIRED TO CLARIFY. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | RESPONSE: | | ARCHITECTURAL PLANS WERE REVISED. NEW FLOOR | | PLANS/ELEVATIONS WERE SUBMITTED BUT NONE OF THE | | STRUCTURAL PLANS WERE REVISED. REVISE ALL STRUCTURAL | | PLANS AND COORDINATE ACCORDINGLY. | | | | ORIGINAL COMMENT: | | 7- PLANS DON'T PROVIDE SPECIFICATIONS FOR THE ROOF | | SHEATHING. SPECIFY TYPE, THICKNESS AND ROOF SHEATHING | | FASTENING AS REQUIRED BY SEC. R803.2.3.1 | | FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. | | | | ORIGINAL COMMENT: | | 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR | | STEEL COLUMNS SHOWN ON THE FRONT PORCH. SPECIFY TOP AND | | BOTTOM CONNECTORS AND FURRING DETAILS. | | SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. | | | | ORIGINAL COMMENT: | | 9- PROVIDE DOORS AND WINDOWS STRUCTURAL BUCK DETAIL. | | NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO | | THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1 | | FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. | | | | ORIGINAL COMMENT: | | 10- REVISE THE ADDRESS INFORMATION ON ALL DRAWINGS, | | CALCULATIONS, ENERGY CALCULATIONS, ETC. SUBMITTED TO | | AVOID CONFLICTS/DELAYS. THERE ARE TWO STRUCTURES IN | | THIS LOT. 839 4TH STREET IS THE ADDRESS FOR THE REAR | | STRUCTURE. THIS PERMIT APPLICATION IS FOR THE REAR | | STRUCTURE ONLY. 837 4TH STREET IS THE MAIN HOUSE. THIS | | WILL FACILITATE INSPECTIONS AND RECORDS KEEPING. | | SEC. 107.2.1.3 CITY AMENDMENTS. | | | | RESPONSE: | | REPEAT COMMENT. | | | | ORIGINAL COMMENT: | | 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR | | | | A)ROOF MATERIAL FOR PITCHED ROOF AS SPECIFIED ON PLANS. | | | | RESPONSE: | | NOA 19-0313.03 SUBMITTED IS FOR FLAT ROOFS OVER | | LIGHTWEIGHT CONCRETE DECKS. THIS IS INCORRECT. PROVIDE | | CORRECT SHINGLES PRODUCT APPROVAL. | | | | B)OK. REVISED PLANS DON'T SHOW FLAT ROOFS NOW. | | | | C)SINGLE HUNG WINDOWS A SPECIFIED ON REVISED PLANS. | | | | D)HARDIEBOARD SIDING. INFORMATION SUBMITTED IS NOT A | | PRODUCT APPROVAL. NEED MIAMI DADE NOA OR COMPLETE | | FLORIDA PRODUCT APPROVAL. | | | | NOTE: CLARIFY WHY SUBMITTING PRODUCT APPROVAL FOR | | HORIZONTAL SLIDER WINDOWS IF THEY ARE NOT SPECIFIED ON | | THE REVISED PLANS? | | | | 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS | | (INCLUDING THE HARDIEBOARD SIDING) AS REQUIRED BY SEC. | | 107.3.4.1 CITY AMENDMENTS. | | | | NEW COMMENTS BASED ON REVISED PLANS. | | 13- SINGLE HUNG WINDOW SIZE SPECIFIED FOR BEDROOM #3 | | DOESN'T COMPLY WITH THE MINIMUM CLEAR OPENING HEIGHT | | REQUIRED BY SEC. R310.2.1 FBC-RESIDENTIAL. REVISE AS | | REQUIRED. | | | | 14- PROVIDE COMPLETE WALL SECTION FROM FOUNDATION | | THROUGH ROOF AS REQUIRED BY SEC. 107.5.3 CITY | | AMENDMENTS. | | | | 15- REVISED ELEVATIONS SHOW WHAT LOOKS LIKE CRAWL SPACE | | VENTILATION. PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS. NOTE: STRUCTURAL PLANS WERE NOT | | REVISED. IT IS NOT KNOW IF THE FLOOR IS GOING TO BE | | WOOD OR CONCRETE SLAB. | | CRAWL SPACE VENTILATION WITH FLOOR JOISTS NEED TO | | COMPLY WITH SEC. R409 FBC-RESIDENTIAL. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-02-17 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-02-17 |
Time |
13:20 |
Sent To |
|
|
Notes |
2021-02-17 13:22:11 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT #20121077 | | | | 1-ENERGY CALCULATIONS SUBMITTED: | | A) THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR | | OTHER AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER | | SHALL CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH | | THE CODE, AS PER SECTION 553.907, FLORIDA STATUTES, | | PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | RENOVATION AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | CONSERVATION. | | | | B) PROVIDE THE NAME OF THE PERSON DOING THE | | CALCULATIONS AS REQUIRED BY SEC. R405.4.2.1 FBC-ENERGY | | CONSERVATION. | | | | C)PROVIDE CORRECT AND COMPLETE INFORMATION ON TOP OF | | FORM. CORRECT ADDRESS IS 839 4TH STREET NOT 837 4TH | | STREET. PROVIDE OWNER'S NAME. PROVIDE BUILDER'S NAME. | | PERMITTING OFFICE IS WEST PALM BEACH NOT PALM BEACH. | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | D)ITEM #8(A) ON PAGE 1 OF 4 SPECIFIES R-5 SLAB-ON-GRADE | | EDGE INSULATION. PLANS DON'T SPECIFY ANY SLAB EDGE | | INSULATION. REVISE AS REQUIRED TO MATCH. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | E)ITEM #9(A) ON PAGE 1 OF 4 SPECIFIES R-4.5 EXTERIOR | | INSULATION ON CONCRETE BLOCK. PLANS DON'T SPECIFY | | EXTERIOR INSULATION ON THE CONCRETE BLOCK. THE | | INSULATION IS ON THE INTERIOR SIDE. SEE PLANS AND | | REVISE AS REQUIRED TO MATCH, INCLUDING R-VALUE | | SPECIFIED. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | F)ITEM #10(A) ON PAGE 1 OF 4 SPECIFIES R-19 UNDER ATTIC | | INSULATION. THIS DOESN'T MATCH PLANS. SEE PLANS AND | | REVISE AS REQUIRED TO MATCH, INCLUDING. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | G)ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 NEEDS TO BE | | COORDINATED WITH PLANS. PLANS ARE NOT CLEAR ON WHAT | | ROOFING MATERIAL IS GOING TO BE INSTALLED BUT IT | | DOESN'T SPECIFY FLAT TILE OR SLATE. COORDINATE WITH | | ENGINEER PLANS AND REVISE AS REQUIRED TO MATCH. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | H)REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 4. PLANS | | DON'T SHOW ANY 1/300 VENT RATIO. TYPICALLY, THE RATIO | | IS 1/150 NOT 1/300. SEC. R806.2 FBC-RESIDENTIAL. OR | | PERSON PREPARING THE ENERGY CALCULATIONS TO PROVIDE | | COMPLETE DETAILS/SPECIFICATIONS SHOWING COMPLIANCE WITH | | THE 1/300 RATIO AS REQUIRED BY THE EXCEPTION ON SEC. | | R806.2. NOTE: ENGINEER OF RECORD NEEDS TO | | REVIEW/APPROVE THEM PRIOR TO SUBMITTAL. | | | | I)DOOR TYPE INFORMATION SPECIFIED ON PAGE 3 OF 4 IS | | INCORRECT. ACCORDING TO PLANS AND PRODUCT APPROVALS | | SUBMITTED THE ENTRY DOOR AND THE BEDROOM #3 DOORS ARE | | ALUMINUM DOORS WITH GLAZING. GLASS IN THESE DOORS NEED | | TO BE INCLUDED ON THE GLASS CALCULATIONS AS REQUIRED BY | | SEC. R405.5.3.1 AND SEC. R405.5.3.3 FBC-ENERGY | | CONSERVATION. REVISE AS REQUIRED. | | | | J)WINDOWS INFORMATION SPECIFIED ON 3 OF 4 DOESN'T MATCH | | PLANS. REVISE THE WINDOW AREA AND WINDOW OVERHANG DEPTH | | AND SEPARATION TO MATCH PLANS. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | 2-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | FOLLOWING: | | R401.3 FBC-RESIDENTIAL. | | SEC. 107.2.5 CITY AMENDMENTS. | | SEC. 110.9 CITY AMENDMENTS. | | | | 3-SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING | | COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL. | | | | 4-PLANS SUBMITTED DON'T SPECIFY WHAT IS THE ROOFING | | MATERIAL. IS IT SHINGLES?, TILE?. IF USING SHINGLES , | | THEN A ROOF PITCH OF 2:12 TO LESS THAN 4:12 REQUIRES | | TWO LAYERS OF UNDERLAYMENT AS REQUIRED BY SEC. R905.2.2 | | FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS ON PLANS FOR | | THE TWO LAYERS OF UNDERLAYMENT. ALSO, PROVIDE | | SPECIFICATIONS FOR THE FLAT ROOF. | | | | 5- SPECIFY ROOF PITCH OF THE FLAT ROOF ON THE FRONT | | PORCH. SEE SEC. R905.9.1 OR 905.11.1 FBC RESIDENTIAL. | | | | 6- BEAM SCHEDULE ON SHEET S-2 ONLY SPECIFIES B-1 BEAM. | | IT DOESN'T SPECIFY THE RAKE BEAM SHOWN ON SHEET S-4. | | REVISE AS REQUIRED TO CLARIFY. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 7- PLANS DON'T PROVIDE SPECIFICATIONS FOR THE ROOF | | SHEATHING. SPECIFY TYPE, THICKNESS AND ROOF SHEATHING | | FASTENING AS REQUIRED BY SEC. R803.2.3.1 | | FBC-RESIDENTIAL. | | | | 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR | | STEEL COLUMNS SHOWN ON THE FRONT PORCH. SPECIFY TOP AND | | BOTTOM CONNECTORS AND FURRING DETAILS. | | SEC. R301.1 FBC-RESIDENTIAL. | | | | 9- PROVIDE DOORS AND WINDOWS STRUCTURAL BUCK DETAIL. | | NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO | | THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1 | | FBC-RESIDENTIAL. | | | | 10- REVISE THE ADDRESS INFORMATION ON ALL DRAWINGS, | | CALCULATIONS, ENERGY CALCULATIONS, ETC. SUBMITTED TO | | AVOID CONFLICTS/DELAYS. THERE ARE TWO STRUCTURES IN | | THIS LOT. 839 4TH STREET IS THE ADDRESS FOR THE REAR | | STRUCTURE. THIS PERMIT APPLICATION IS FOR THE REAR | | STRUCTURE ONLY. 837 4TH STREET IS THE MAIN HOUSE. THIS | | WILL FACILITATE INSPECTIONS AND RECORDS KEEPING. | | SEC. 107.2.1.3 CITY AMENDMENTS. | | | | 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL): | | | | A)ROOF MATERIAL FOR PITCHED ROOF AS SPECIFIED ON PLANS. | | | | B) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 13-VALUATION DECLARED IN THE PERMIT APPLICATION IS LOW. | | VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S | | OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS | | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. VALUATION WAS | | UPDATED TO $120,957. THE PERMIT FEE BALANCE IS | | $2456.00. | | | | 14- ENGINEER TO FOLLOW UP WITH THE FLORIDA BUILDING | | CODE TRAINING REQUIREMENT. SEE BELOW: | | | | FLORIDA BUILDING CODE TRAINING FOR ENGINEERS(471.0195 | | F.S.) | | | | 471.0195 FLORIDA BUILDING CODE TRAINING FOR ENGINEERS. | | ALL LICENSEES ACTIVELY PARTICIPATING IN THE DESIGN OF | | ENGINEERING WORKS OR SYSTEMS IN CONNECTION WITH | | BUILDINGS, STRUCTURES, OR FACILITIES AND SYSTEMS | | COVERED BY THE FLORIDA BUILDING CODE SHALL TAKE | | CONTINUING EDUCATION COURSES AND SUBMIT PROOF TO THE | | BOARD, AT SUCH TIMES AND IN SUCH MANNER AS ESTABLISHED | | BY THE BOARD BY RULE, THAT THE LICENSEE HAS COMPLETED | | ANY SPECIALIZED OR ADVANCED COURSES ON ANY PORTION OF | | THE FLORIDA BUILDING CODE APPLICABLE TO THE LICENSEE'S | | AREA OF PRACTICE. THE BOARD SHALL RECORD REPORTED | | CONTINUING EDUCATION COURSES ON A SYSTEM EASILY | | ACCESSED BY CODE ENFORCEMENT JURISDICTIONS FOR | | EVALUATION WHEN DETERMINING LICENSE STATUS FOR PURPOSES | | OF PROCESSING DESIGN DOCUMENTS. LOCAL JURISDICTIONS | | SHALL BE RESPONSIBLE FOR NOTIFYING THE BOARD WHEN | | DESIGN DOCUMENTS ARE SUBMITTED FOR BUILDING | | CONSTRUCTION PERMITS BY PERSONS WHO ARE NOT IN | | COMPLIANCE WITH THIS SECTION. THE BOARD SHALL TAKE | | APPROPRIATE ACTION AS PROVIDED BY ITS RULES WHEN SUCH | | NONCOMPLIANCE IS DETERMINED TO EXIST. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-10-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-10-26 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-10-26 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-08-06 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-06 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-06 |
Time |
07:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-02-01 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-02-01 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-02-01 |
Time |
14:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
5 |
Status |
P |
Date |
2022-12-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2022-12-28 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2022-12-28 |
Time |
12:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-06-06 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-06-06 |
Time |
16:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2021-10-21 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2021-10-21 |
Time |
08:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2021-09-02 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-09-02 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-09-02 |
Time |
12:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2021-01-28 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2021-01-28 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2021-01-27 |
Time |
16:54 |
Sent To |
|
|
Notes |
2021-01-28 12:37:21 | THIS PROJECT HAS TWO AVENUES TO PROCEED: | | OPTION A: | | 1. A CERTIFICATE OF APPROPRIATENESS (COA) APPLICATION | | IS REQUIRED FOR NEW CONSTRUCTION WITHIN THE NORTHWEST | | HISTORIC DISTRICT. PLEASE EMAIL STAFF AT | | [email protected] TO REQUEST A COPY OF THE | | APPLICATION. INCLUDE ALL APPLICATION MATERIALS REQUIRED | | UNDER ?NEW CONSTRUCTION?. THE NEXT APPLICATION DEADLINE | | IS FEBRUARY 17, 2021 FOR THE MARCH 23, 2021 HISTORIC | | PRESERVATION BOARD MEETING. | | | | THE APPLICATION FEE IS $350.00 + $0.01 PER SQUARE FOOT. | | STAFF RECOMMENDS ADDRESSING THE FOLLOWING COMMENTS | | BEFORE SUBMITTING A COA APPLICATION. ADDITIONAL | | COMMENTS DURING STAFF?S REPORT OR BY THE HISTORIC | | PRESERVATION MAY NEED TO BE ADDRESSED PRIOR TO A PERMIT | | BEING ISSUED. | | | | 1. THE TOTAL FLOOR AREA OF ALL ROOFED ACCESSORY | | BUILDINGS ON A PROPERTY SHALL NOT EXCEED 75 PERCENT OF | | THE GROSS FLOOR AREA OF THE PRIMARY STRUCTURE WITH A | | MAXIMUM FLOOR AREA OF 1,000 SQUARE FEET. (SEC. | | 94-304(B)(1)). SEE SEC. 94-86 FOR HISTORIC RESIDENTIAL | | DISTRICT DEFINITIONS FOR HOW TO CALCULATE LOT COVERAGE. | | 2. REVISE ALL WINDOWS TO BE A SASH WINDOW WITH | | TRADITIONAL WINDOW OPENINGS. | | 3. REVISE ALL DOOR OPENINGS TO BE A TRADITIONAL SINGLE | | OR PAIRED FRENCH DOOR. | | 4. REVISE RAILINGS TO BE VERTICAL TO EMPHASIZE A | | TRADITIONAL RAILING. | | 5. REVISE STUCCO EXTERIOR TO HAVE SIDING. THE SIDING | | MAY BE WOOD, BORAL TRUEXTERIOR, OR HARDIEBOARD SMOOTH | | IN A CHANNEL BEVEL PROFILE TO MATCH THE PREVIOUS | | CONTRIBUTING ACCESSORY STRUCTURE. | | 6. REVISE ALL WINDOW FRAMES TO HAVE WHITE FRAMES AND | | CLEAR GLASS OR CLEAR GLASS WITH LOW-E COATING. | | 7. REVISE THE FRONT PORCH POST TO BE WOOD OR WOOD | | ALTERNATE PRODUCT SUCH AS TREX. | | 8. REVISE THE REAR PORCH TO HAVE A WOOD LIKE MASSING | | FOR THE COLUMNS. | | 9. INDICATE ROOFING MATERIAL. | | | | OPTION B: | | | | STAFF RECOMMENDS THIS OPTION. | | | | REVISE THE PLANS TO BUILD A MODIFIED RECONSTRUCTION OF | | THE STRUCTURE THAT WAS PREVIOUSLY CONTRIBUTING. A | | MODIFIED RECONSTRUCTION MAY BE BUILT WITH CMU BLOCKS | | AND HAVE SIDING WITH BORAL TRUEXTERIOR OR HARDIEBOARD | | SMOOTH. THE ENTIRE FRONT PORCH MAY BE A WOOD ALTERNATE | | PRODUCT SUCH AS TREX. | | | | IF THIS APPROACH IS SELECTED, STAFF WILL SUPPORT AN AD | | VALOREM TAX EXEMPTION. THE AD VALOREM TAX EXEMPTION | | PROGRAM: | | THE CITY OF WEST PALM BEACH AND PALM BEACH COUNTY HAVE | | PASSED PROPERTY TAX ABATEMENT EXEMPTION ORDINANCES, | | WHICH AUTHORIZE GRANTING AN EXEMPTION FROM INCREASES TO | | AD VALOREM TAXES FOR QUALIFIED IMPROVEMENTS TO | | PROPERTIES LISTED IN THE WEST PALM BEACH REGISTER OF | | HISTORIC PLACES. THIS EXEMPTION DOES NOT APPLY TO | | ASSESSED LAND VALUE, ONLY TO THE VALUE OF THE | | IMPROVEMENTS. | | | | THE CITY AND THE COUNTY WILL PROCESS THE APPLICATION | | FOLLOWING MUTUALLY ESTABLISHED PROCEDURES THROUGH BOTH | | THE CITY AND COUNTY COMMISSIONS. ONCE THE HISTORIC | | PRESERVATION BOARD HAS APPROVED THE WORK, THE OWNER HAS | | TWO (2) YEARS TO COMPLETE THE IMPROVEMENTS. | | | | THIS PROGRAM PROVIDES AN ABATEMENT OF TAX INCREASES ON | | THE IMPROVEMENTS TO THE PROPERTY FOR A TEN (10) YEAR | | PERIOD. THE ABATEMENT IS CONVEYED THROUGH A COVENANT | | THAT ACCOMPANIES THE DEED OF THE PROPERTY AND MAY BE | | TRANSFERRED TO FUTURE OWNERS DURING THE ABATEMENT TIME | | PERIOD. | | | | A CERTIFICATE OF APPROPRIATENESS (COA) APPLICATION WILL | | BE REQUIRED IN ADDITION TO AN AD VALOREM | | PRECONSTRUCTION APPLICATION. ALL MATERIALS REQUIRED | | UNDER THE ?AD VALOREM TAX EXEMPTION? WILL BE REQUIRED | | IN ADDITION TO ROOF PLAN, SECTIONS, PROJECT DATA TABLE, | | AND NOTIFICATION. THE APPLICATION FEE IS $250.00. THE | | NEXT APPLICATION DEADLINE IS FEBRUARY 17, 2021 FOR THE | | MARCH 23, 2021 HISTORIC PRESERVATION BOARD MEETING. | | | | AN AD VALOREM APPLICATION CAN BE COMBINED FOR ONE (1) | | APPLICATION FOR BOTH STRUCTURES ON THE PROPERTY ONLY IF | | DOING THE MODIFIED RECONSTRUCTION OPTION. IF NOT, A | | SEPARATE APPLICATION WILL BE REQUIRED FOR THE NEW | | CONSTRUCTION ACCESSORY STRUCTURE AND THE AD VALOREM TAX | | EXEMPTION ON THE PRIMARY STRUCTURE. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | PLANNING DIVISION | | [email protected] | OFFICE: 561.822.1428 | TTY: | | 800.955.8771 | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | FL 33402 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2023-07-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-07-21 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-06-28 |
Time |
09:06 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2023-03-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-03-03 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-02-16 |
Time |
16:24 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2022-12-29 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-12-29 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-11-22 |
Time |
08:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-07-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-12 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-05-25 |
Time |
08:37 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-10-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-10-26 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-10-01 |
Time |
06:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-09-02 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-09-02 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-07-28 |
Time |
10:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-02-17 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-01-20 |
Time |
12:05 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
F |
Date |
2023-07-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-07-21 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-07-21 |
Time |
17:17 |
Sent To |
|
|
Notes |
2023-07-21 17:17:38 | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2023-03-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-03-03 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-03-03 |
Time |
14:14 |
Sent To |
|
|
Notes |
2023-03-03 14:15:03 | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2022-12-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-12-27 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-12-27 |
Time |
16:49 |
Sent To |
|
|
Notes |
2022-12-27 16:49:52 | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-02-17 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-02-17 |
Time |
10:48 |
Sent To |
|
|
Notes |
2021-02-17 10:50:09 | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2021-10-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-10-04 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-10-04 |
Time |
10:00 |
Sent To |
|
|
Notes |
2021-10-04 10:01:04 | APPROVED WITH PRIVISO: | | THE DRYER EXHAUST MUST MEET FBC RES M1502 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2021-08-04 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2021-08-04 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2021-08-04 |
Time |
13:59 |
Sent To |
|
|
Notes |
2021-08-04 14:57:27 | PLAN DENIED | | REFER TO SECTION M1401.3 EQUIPMENT AND APPLIANCE | | SIZING. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2021-01-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2021-01-27 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2021-01-27 |
Time |
10:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2021-10-18 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-10-18 |
Time |
06:05 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-10-18 |
Time |
05:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2021-08-03 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-08-03 |
Time |
18:20 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-08-03 |
Time |
18:20 |
Sent To |
|
|
Notes |
2021-08-03 18:21:11 | 08/03/21 2ND REQUEST PLUMBING REVIEW**DENIED** WITH | | COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. PLEASE PROVIDE A PLUMBING ISOMETRIC RISER DIAGRAM | | PER THE WPB AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12) | | RESIDENTIAL PLUMBING. | | | | 2. THIS IS A MULTI-FAMILY DWELLING, AND WATER USERS | | WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION | | ASSEMBLY AT THE POINT OF DELIVERY. THE TYPE OF BACKFLOW | | ASSEMBLY REQUIRED WILL BE DEPENDENT UPON THE DEGREE OF | | HAZARD POSED BY THE WATER USER. A REDUCED PRESSURE ZONE | | BACKFLOW DEVICE WILL BE NEEDED FOR THE WATER METER PER | | THE CITY OF WEST PALM CROSS UTILITIES DEPARTMENT AND | | THEIR CONNECTION CONTROL PROGRAM. | | | | 3. ON SHEET P-1 THE DRAIN ON THE STACK LOOKS LIKE A | | COMBINATION FITTING, AND IT IS NOT ALLOWED ON A | | HORIZONTAL DRAIN. YOU CAN PUT A NOT OR CHANGE THE | | FITTING TO REFLECT A SANITARY FITTING PER THE WPB | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL | | PLUMBING. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-01-21 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-21 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-01-21 |
Time |
17:40 |
Sent To |
|
|
Notes |
2021-01-21 17:40:45 | 01/21/21 PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. PLEASE PROVIDE A PLUMBING ISOMETRIC RISER DIAGRAM | | PER THE WPB AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12) | | RESIDENTIAL PLUMBING. | | | | 2. THIS IS A MULTI-FAMILY DWELLING, AND WATER USERS | | WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION | | ASSEMBLY AT THE POINT OF DELIVERY. THE TYPE OF BACKFLOW | | ASSEMBLY REQUIRED WILL BE DEPENDENT UPON THE DEGREE OF | | HAZARD POSED BY THE WATER USER. A REDUCED PRESSURE ZONE | | BACKFLOW DEVICE WILL BE NEEDED FOR THE WATER METER PER | | THE CITY OF WEST PALM CROSS UTILITIES DEPARTMENT AND | | THEIR CONNECTION CONTROL PROGRAM. | | | | 3. ON SHEET P-1 THE DRAIN ON THE STACK LOOKS LIKE A | | COMBINATION FITTING, AND IT IS NOT ALLOWED ON A | | HORIZONTAL DRAIN. YOU CAN PUT A NOT OR CHANGE THE | | FITTING TO REFLECT A SANITARY FITTING PER THE WPB | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL | | PLUMBING. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
5 |
Status |
P |
Date |
2022-12-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-12-27 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-12-27 |
Time |
16:51 |
Sent To |
|
|
Notes |
2022-12-27 16:54:04 | 1-ROOF SHINGLES FL31588-R2. | | | | 2- SHINGLES UNDERLAYMENT NOA 21-1130.01 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
F |
Date |
2022-07-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-12 |
Time |
17:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-12 |
Time |
17:35 |
Sent To |
|
|
Notes |
2022-07-12 17:37:29 | ROOFING REVIEW: | | | | 1 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR | | | | ORIGINAL COMMENT: | | A)OK. ROOF SHINGLES FL31588-R2. | | | | B) PROVIDE PRODUCT APPROVAL FOR SHINGLES UNDERLAYMENT | | SPECIFIED ON TYPICAL WALL SECTION ON SHEET A-1. | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS | | (INCLUDING THE HARDIEBOARD SIDING) AS REQUIRED BY SEC. | | 107.3.4.1 CITY AMENDMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2021-10-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-10-21 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-10-21 |
Time |
15:29 |
Sent To |
|
|
Notes |
2021-10-21 15:30:10 | ROOFING REVIEW: | | | | 1 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR | | | | ORIGINAL COMMENT: | | A)ROOF MATERIAL FOR PITCHED ROOF AS SPECIFIED ON PLANS. | | | | RESPONSE: | | NOA 19-0617.05 SUBMITTED NOW IS NOT FOR SHINGLES. WRONG | | NOA AGAIN. | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS | | (INCLUDING THE HARDIEBOARD SIDING) AS REQUIRED BY SEC. | | 107.3.4.1 CITY AMENDMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2021-08-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-08-17 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-08-17 |
Time |
13:24 |
Sent To |
|
|
Notes |
2021-08-17 13:24:31 | ROOFING SECOND REVIEW: | | | | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL): | | | | A)ROOF MATERIAL FOR PITCHED ROOF AS SPECIFIED ON PLANS. | | | | RESPONSE: | | NOA 19-0313.03 SUBMITTED IS FOR FLAT ROOFS OVER | | LIGHTWEIGHT CONCRETE DECKS. THIS IS INCORRECT. PROVIDE | | CORRECT SHINGLES PRODUCT APPROVAL. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-02-17 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-02-17 |
Time |
13:22 |
Sent To |
|
|
Notes |
2021-02-17 13:23:30 | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL): | | | | A)ROOF MATERIAL FOR PITCHED ROOF AS SPECIFIED ON PLANS. | | | | B) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
7 |
Status |
P |
Date |
2023-07-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-07-21 |
Time |
18:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-07-21 |
Time |
18:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
F |
Date |
2023-03-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-03-03 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-03-03 |
Time |
10:27 |
Sent To |
|
|
Notes |
2023-03-03 10:28:12 | ENGINEER'S SELF CERTIFIED DIGITAL SIGNATURE | | 1- DRAWINGS A1, S1, S2, S3 AND S5 HAVE ENGINEER'S | | SELF-CERTIFIED SIGNATURE. A THIRD PARTY CERTIFICATION | | IS REQUIRED. | | FAC 61G15-23.004. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2022-12-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-12-27 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-12-27 |
Time |
16:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2022-07-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-12 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-12 |
Time |
17:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-10-21 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-10-21 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-08-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-08-17 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-08-17 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2021-02-17 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-02-17 |
Time |
13:23 |
Sent To |
|
|
Notes |
2021-02-01 16:47:27 | PLEASE SEE HISTORIC COMMENTS REGARDING ARCHITECTURE AND | | NECESSARY ACTIONS FOR APPROVAL | | | | LOT COVERAGE FOR THIS LOT IS MAXIMUM 30 PERCENT. PLEASE | | CLARIFY THE LOT COVERAGE BASED ON HISTORIC CALCULATIONS | | BELOW AND INCLUDE A TABLE BREAKING DOWN WHAT IS BEING | | COUNTED: | | | | BUILDING FOOTPRINT CALCULATED USING THE ASSIGNED LOT | | COVERAGE INCLUDES 100 PERCENT OF THE GROUND FLOOR AREA | | OF THE FOLLOWING STRUCTURES AND BUILDING ELEMENTS: | | | | ACCESSORY STRUCTURES SUCH AS SHEDS, GUEST HOUSES AND | | SECOND UNITS THAT ARE ROOFED AND ENCLOSED ON MORE THAN | | TWO SIDES WHETHER OR NOT THEY INCLUDE HABITABLE SPACE; | | ATTACHED AND DETACHED GARAGES; | | STAIRWAYS: THE GROUND FLOOR OF INTERIOR AND ROOFED | | EXTERIOR STAIRWAYS, ELEVATORS, ESCALATORS AND SIMILAR | | FEATURES. THE GROUND FLOOR AREA OF USABLE SPACES HAVING | | A 5' MINIMUM HEIGHT UNDER A RUN OF STAIRS SHALL BE | | COUNTED; | | UTILITY AREAS: THE GROUND FLOOR AREA OF LAUNDRY ROOMS, | | MECHANICAL ROOMS, CLOSETS, STORAGE ROOMS AND BUILT-IN | | CABINETS. | | BUILDING FOOTPRINT CALCULATED USING THE ASSIGNED LOT | | COVERAGE INCLUDES 50 PERCENT OF THE GROUND FLOOR AREA | | OF THE FOLLOWING STRUCTURES AND BUILDING ELEMENTS: | | | | ROOFED BUT OPEN CARPORTS THAT ARE ATTACHED TO A | | PRINCIPAL OR ACCESSORY STRUCTURE BUT NOT ENCLOSED BY | | SOLID WALLS ON MORE THAN TWO SIDES; | | ROOFED BUT OPEN PORCHES THAT ARE ATTACHED TO A | | PRINCIPAL OR ACCESSORY STRUCTURE BUT NOT ENCLOSED BY | | SOLID WALLS ON MORE THAN TWO SIDES; | | ROOFED BUT OPEN BREEZEWAYS THAT ARE ATTACHED TO A | | PRINCIPAL OR ACCESSORY STRUCTURE BUT NOT ENCLOSED BY | | SOLID WALLS ON MORE THAN TWO SIDES. | | BUILDING FOOTPRINT CALCULATED USING THE ASSIGNED LOT | | COVERAGE DOES NOT INCLUDE ANY OF THE GROUND FLOOR AREA | | OF THE FOLLOWING STRUCTURES AND BUILDING ELEMENTS: | | | | FREE-STANDING PATIOS, DECKS AND GAZEBOS THAT ARE ROOFED | | BUT NOT ENCLOSED BY SOLID WALLS ON MORE THAN ONE SIDE | | AND NOT ATTACHED TO A PRINCIPAL OR ACCESSORY STRUCTURE. | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT MEETING | | REQUIREMENTS OF SECTION 94-113 | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | 561 822 1426 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
Sent By |
cibaven |
Date |
2023-07-14 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
cibaven |
Date |
2023-07-14 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2022-12-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2022-12-28 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2022-12-28 |
Time |
12:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2022-06-06 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-06-06 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2021-10-12 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2021-10-12 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2021-10-12 |
Time |
15:37 |
Sent To |
|
|
Notes |
2021-10-12 15:37:16 | REPEAT COMMENTS: | | | | 1. PLEASE PROVIDE A COPY OF A CURRENT SURVEY FOR THE | | PROPERTY. | | | | 2. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT MEETING | | THE REQUIREMENTS OF SECTION 94-113. | | | | - THE VALUE OF THE CONSTRUCTION ($120,957) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($40,990) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | SITE INTO CONFORMITY. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-08-05 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2021-08-05 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2021-08-05 |
Time |
14:41 |
Sent To |
|
|
Notes |
2021-08-05 14:42:15 | PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, | | WHICH INCLUDES THE PROPERTY'S ADDRESS AND LEGAL | | DESCRIPTION. | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT MEETING THE | | REQUIREMENTS OF SECTION 94-113. | | - THE VALUE OF THE CONSTRUCTION ($120,957) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($40,990) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | SITE INTO CONFORMITY. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-02-01 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2021-02-01 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2021-02-01 |
Time |
16:47 |
Sent To |
|
|
Notes |
2021-02-01 16:47:51 | PLEASE SEE HISTORIC COMMENTS REGARDING ARCHITECTURE AND | | NECESSARY ACTIONS FOR APPROVAL | | | | LOT COVERAGE FOR THIS LOT IS MAXIMUM 30 PERCENT. PLEASE | | CLARIFY THE LOT COVERAGE BASED ON HISTORIC CALCULATIONS | | BELOW AND INCLUDE A TABLE BREAKING DOWN WHAT IS BEING | | COUNTED: | | | | BUILDING FOOTPRINT CALCULATED USING THE ASSIGNED LOT | | COVERAGE INCLUDES 100 PERCENT OF THE GROUND FLOOR AREA | | OF THE FOLLOWING STRUCTURES AND BUILDING ELEMENTS: | | | | ACCESSORY STRUCTURES SUCH AS SHEDS, GUEST HOUSES AND | | SECOND UNITS THAT ARE ROOFED AND ENCLOSED ON MORE THAN | | TWO SIDES WHETHER OR NOT THEY INCLUDE HABITABLE SPACE; | | ATTACHED AND DETACHED GARAGES; | | STAIRWAYS: THE GROUND FLOOR OF INTERIOR AND ROOFED | | EXTERIOR STAIRWAYS, ELEVATORS, ESCALATORS AND SIMILAR | | FEATURES. THE GROUND FLOOR AREA OF USABLE SPACES HAVING | | A 5' MINIMUM HEIGHT UNDER A RUN OF STAIRS SHALL BE | | COUNTED; | | UTILITY AREAS: THE GROUND FLOOR AREA OF LAUNDRY ROOMS, | | MECHANICAL ROOMS, CLOSETS, STORAGE ROOMS AND BUILT-IN | | CABINETS. | | BUILDING FOOTPRINT CALCULATED USING THE ASSIGNED LOT | | COVERAGE INCLUDES 50 PERCENT OF THE GROUND FLOOR AREA | | OF THE FOLLOWING STRUCTURES AND BUILDING ELEMENTS: | | | | ROOFED BUT OPEN CARPORTS THAT ARE ATTACHED TO A | | PRINCIPAL OR ACCESSORY STRUCTURE BUT NOT ENCLOSED BY | | SOLID WALLS ON MORE THAN TWO SIDES; | | ROOFED BUT OPEN PORCHES THAT ARE ATTACHED TO A | | PRINCIPAL OR ACCESSORY STRUCTURE BUT NOT ENCLOSED BY | | SOLID WALLS ON MORE THAN TWO SIDES; | | ROOFED BUT OPEN BREEZEWAYS THAT ARE ATTACHED TO A | | PRINCIPAL OR ACCESSORY STRUCTURE BUT NOT ENCLOSED BY | | SOLID WALLS ON MORE THAN TWO SIDES. | | BUILDING FOOTPRINT CALCULATED USING THE ASSIGNED LOT | | COVERAGE DOES NOT INCLUDE ANY OF THE GROUND FLOOR AREA | | OF THE FOLLOWING STRUCTURES AND BUILDING ELEMENTS: | | | | FREE-STANDING PATIOS, DECKS AND GAZEBOS THAT ARE ROOFED | | BUT NOT ENCLOSED BY SOLID WALLS ON MORE THAN ONE SIDE | | AND NOT ATTACHED TO A PRINCIPAL OR ACCESSORY STRUCTURE. | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT MEETING | | REQUIREMENTS OF SECTION 94-113 | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | 561 822 1426 | | [email protected] |
|
|