Plan Review Details - Permit 20120986
Plan Review Stops For Permit 20120986
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2020-12-30 Cont ID  
Sent By cpuell Date 2020-12-30 Time 16:03 Rev Time 0.00
Received By cpuell Date 2020-12-30 Time 16:03 Sent To  
Notes
2020-12-30 16:03:475TH FLOOR ADDED, TENANT TAKING OVER THE WHOLE FLOOR

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-12-29 Cont ID  
Sent By cpuell Date 2020-12-29 Time 12:20 Rev Time 0.00
Received By cpuell Date 2020-12-29 Time 12:20 Sent To  
Notes
2020-12-29 12:20:49IS THERE A SUITE NUMBER PLEASE REACH OUT TO
 [email protected]

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-02-05 Cont ID  
Sent By jwitmer Date 2021-02-05 Time 08:59 Rev Time 0.00
Received By jwitmer Date 2021-02-05 Time 08:56 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-01-19 Cont ID  
Sent By jwitmer Date 2021-01-19 Time 16:32 Rev Time  
Received By jwitmer Date 2021-01-19 Time 16:28 Sent To  
Notes
2021-01-19 16:30:18TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING: THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-02-05 Cont ID  
Sent By jwitmer Date 2021-02-05 Time 09:16 Rev Time 0.00
Received By jwitmer Date 2021-02-05 Time 08:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-01-20 Cont ID  
Sent By jwitmer Date 2021-01-20 Time 10:42 Rev Time 0.00
Received By jwitmer Date 2021-01-19 Time 16:28 Sent To  
Notes
2021-01-20 10:41:50WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20120986
 ADD: 2000 PALM BEACH LAKES BLVD. 5TH FLOOR.
 CONT: CAMPBELL GENERAL CONTRACTING, INC.
 TEL: 772-486-3764
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JAN. 20/ 2021
 ACTION: DENIED
  
 1) SHEET AE101 THE FLOOR PLAN INDICATES THE BREAK ROOM
 AS ROOM # 527. WITHIN THE BREAKROOM THERE IS A COUNTER
 AND BREAKROOM SINK. THE FLOOR PLAN DOES NOT SHOW
 COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY CODE FOR
 CLEAR FLOOR SPACE, EITHER A FRONT APPROACH OR SIDE
 APPROACH.
 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING
 WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE
 AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED,
 SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED CLEAR FLOOR
 SPACE ON THE FLOOR PLAN.
  
 2) SHEET AE101 THE FLOOR PLAN INDICATES THE BREAK ROOM
 AS ROOM # 527. THIS SHEET INDICATES DETAIL SHEET AE 501
 DETAIL B SHOWS THE BREAK ROOM SINK & BASE CABINETS AT A
 HEIGHT OF 34 INCHES. A CUT SECTION THROUGH THE CABINET
 AE 501 DETAIL 2 SHOWS THERE IS NO SHELVING IN THIS
 CABINET BUT THERE IS A BOTTOM IN THE CABINET. ELEVATION
 B SHOWS A PAIR OF DOORS AT THE SINK WITH NO BOTTOM
 THERE IS A DISCREPANCY IN THE PLANS. IF A FRONT
 APPROACH IS TO BE INDICATED, PLEASE ALSO SHOW
 COMPLIANCE WITH SECTION 606.5 OF THE 2017
 FBC-ACCESSIBILITY CODE. EXPOSED PIPES AND SURFACES.
 WATER SUPPLY & DRAINPIPES UNDER LAVATORIES AND SINKS
 SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT
 AGAINST CONTACT.
  
 3) SHEET AE101 THE FLOOR PLAN INDICATES THE RESTROOM
 526. SHEET AE 701 THE FINISH SCHEDULE INDICATES THE
 RESTROOM WALLS ARE TO HAVE A PAINT GRADE FINISH ON THE
 WALLS.
  
 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT
 IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON
 06/2020. IN RESTROOMS & SERVICE SINK AREAS EPOXY PAINT
 IS NO LONGER CONSIDERED A SMOOTH HARD, NON-ABSORBENT
 SURFACE.
  
 3A) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF
 SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A
 SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT
 LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL
 ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A
 TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 3B) 2509.1. WET AREAS. SHOWERS AND PUBLIC TOILET WALLS
 SHALL COMPLY WITH 1210.2.
  
 3C) 1210.2. FINISH MATERIALS. WALLS, BASE, FLOORS AND
 PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY WITH
 SECTIONS 1210.1 THROUGH 1210.4.
  
 4) IT WOULD APPEAR THERE IS NO WORK TO BE COMPLETED IN
 THE COMMON LOBBY. THIS WHERE THE DRINKING FOUNTAIN IS
 FOUND. IT WOULD APPEAR THE EXISTING DRINKING FOUNTAIN
 IS A SINGLE FOUNTAIN. SHEET AE 702 DOES SHOW A PROFILE
 OF WHAT APPEARS TO BE A SINGLE DRINKING FOUNTAIN.
 NEITHER THE DETAIL NOR SINGLE DRINKING FOUNTAIN COMPLY
 WITH TODAYS 2017 ACCESSIBILITY CODE SECTION. NO FEWER
 THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE
 DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6
 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.7. I DO
 NOT BELIEVE THIS CAN BE ENFORCED AT THIS TIME IF THERE
 IS NO WORK TO BE COMPLETE OUTSIDE OF THE TENANT SPACE,
 ( DRINKING FOUNTAIN IN THE COMMON AREAS), BUT THE
 DETAIL SHOULD EITHER BE REMOVED OR UPDATED FOR FUTURE
 USE. THE PLUMBING PLAN REVIEWER MAY HAVE MORE COMMENTS
 ON THIS MATTER.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-02-23 Cont ID  
Sent By jleahy Date 2021-02-23 Time 11:05 Rev Time 0.00
Received By jleahy Date 2021-02-23 Time 10:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-01-20 Cont ID  
Sent By jleahy Date 2021-01-20 Time 12:16 Rev Time 0.00
Received By jleahy Date 2021-01-20 Time 11:54 Sent To  
Notes
2021-01-20 12:20:42ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 OUTLETS IN EXAM ROOM TO BE WIRED PER 517.13
  
 517.13 GROUNDING OF RECEPTACLES AND FIXED ELECTRICAL
 EQUIPMENT IN PATIENT CARE SPACES. WIRING IN PATIENT
 CARE SPACES SHALL COMPLY WITH 517.13(A) AND (B). (A)
 WIRING METHODS. ALL BRANCH CIRCUITS SERVING PATIENT
 CARE SPACES SHALL BE PROVIDED WITH AN EFFECTIVE
 GROUND-FAULT CURRENT PATH BY INSTALLATION IN A METAL
 RACEWAY SYSTEM OR A CABLE HAVING A METALLIC ARMOR OR
 SHEATH ASSEMBLY. THE METAL RACEWAY SYSTEM, METALLIC
 CABLE ARMOR, OR SHEATH ASSEMBLY SHALL ITSELF QUALIFY AS
 AN EQUIPMENT GROUNDING CONDUCTOR IN ACCORDANCE WITH
 250.118. (B) INSULATED EQUIPMENT GROUNDING CONDUCTORS
 AND INSULATED EQUIPMENT BONDING JUMPERS. (1) GENERAL.
 THE FOLLOWING SHALL BE DIRECTLY CONNECTED TO AN
 INSULATED COPPER EQUIPMENT GROUNDING CONDUCTOR THAT IS
 CLEARLY IDENTIFIED ALONG ITS ENTIRE LENGTH BY GREEN
 INSULATION AND INSTALLED WITH THE BRANCH CIRCUIT
 CONDUCTORS IN THE WIRING METHODS AS PROVIDED IN
 517.13(A): (1) THE GROUNDING TERMINALS OF ALL
 RECEPTACLES OTHER THAN ISOLATED GROUND RECEPTACLES (2)
 METAL OUTLET BOXES, METAL DEVICE BOXES, OR METAL
 ENCLOSURES (3) ALL NON?CURRENT-CARRYING CONDUCTIVE
 SURFACES OF FIXED ELECTRICAL EQUIPMENT LIKELY TO BECOME
 ENERGIZED THAT ARE SUBJECT TO PERSONAL CONTACT,
 OPERATING AT OVER 100 VOLTS

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-02-08 Cont ID  
Sent By bdolan Date 2021-02-08 Time   Rev Time 0.00
Received By bdolan Date 2021-02-08 Time 13:48 Sent To  
Notes
2021-02-08 13:48:47THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE
 CURRENT CODES IN EFFECT IN THIS JURISDICTION AT THE
 TIME OF THE ORIGINAL APPLICATION. PERFORMANCE OF THIS
 REVIEW SHALL NOT ALLEVIATE THE APPLICANT FROM FULL
 RESPONSIBILITY TO COMPLY WITH ALL APPLICABLE
 REQUIREMENTS.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS MAY REQUIRE AN EVALUATION OF THE FIRE ALARM
 SYSTEM OR DEVICES FOR CODE COVERAGE AND COMPLIANCE BY
 CERTIFIED CONTRACTORS.
  
 ANY AND ALL WORK ON THE FIRE ALARM SYSTEM/EQUIPMENT
 SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS
 BY CERTIFIED CONTRACTORS.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2020-12-28 Time   Rev Time 0.00
Received By bdolan Date 2020-12-28 Time 11:45 Sent To  
Notes
2020-12-28 11:48:28THIS PLAN WAS REVIEWED AND APPROVED BY LT. BRIAN DOLAN,
 PLAN REVIEWER, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING/WALL
 AREAS MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE
 FIRE SPRINKLER AND FIRE ALARM SYSTEMS FOR CODE COVERAGE
 AND COMPLIANCE BY CERTIFIED CONTRACTORS.
  
 2) ANY AND ALL WORK ON THE FIRE SPRINKLER AND/OR FIRE
 ALARM SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS AND
 SHOP DRAWINGS BY CERTIFIED CONTRACTORS.
  
 3) THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL
 REMAIN ACTIVE THROUGHOUT THE DEMO AND CONSTRUCTION
 PERIODS.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-03-03 Cont ID  
Sent By ccarvaja Date 2021-03-03 Time 08:50 Rev Time 0.00
Received By ccarvaja Date 2021-03-02 Time 08:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-01 Cont ID  
Sent By lmarchan Date 2021-03-01 Time 11:12 Rev Time 0.00
Received By lmarchan Date 2021-02-02 Time 11:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-21 Cont ID  
Sent By lmarchan Date 2021-01-21 Time 13:43 Rev Time 0.00
Received By lmarchan Date 2020-12-22 Time 09:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-01-14 Cont ID  
Sent By medwards Date 2021-01-14 Time 06:39 Rev Time 0.00
Received By medwards Date 2021-01-14 Time 06:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-02-27 Cont ID  
Sent By abelisle Date 2021-02-27 Time 11:28 Rev Time 0.00
Received By abelisle Date 2021-02-27 Time 05:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-01-21 Cont ID  
Sent By tklarge Date 2021-01-21 Time 07:52 Rev Time 0.00
Received By tklarge Date 2021-01-19 Time 14:50 Sent To  
Notes
2021-01-21 06:58:421) PROVIDE AN ENLARGED FLOOR PLAN FOR THE NEW HANDIAP
 ACCESSIBLE TOILET ROOM # 526. SHOW THE INSIDE CLEAR
 DIMENSIONS (L X W) OF THE TOILET ROOM AND THE LENGTH
 AND WIDTH DIMENSIONS OF THE CLEAR FLOOR SPACES FOR THE
 LAVATORY AND THE WATER CLOSET. WPB AND. TO FBC SEC.
 107.2.1.
 2) SHT. AE 101 - SHOW THE REQUIRED CLEAR FLOOR SPACE
 AND KNEE AND TOE CLEARANCES FOR THE BREAK ROOM SINK.
 SHOW THE DIMENSIONS OF THE CLEAR FLOOR SPACE. COMPLY
 WITH FBC-ACCESS. SEC. 305, 306, 606.2.
 3) SHT. AE 101 SHOWS TWO SETS OF EXAM ROOMS LABELED #5,
 6,& 7. CLARIFY.
 4) SHT. AE 502 SHOWS GRAB BARS IN A VERTICAL POSITION.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION
 PER HE FBC-ACCESS. SEC. 609.4. TTHERE IS NO EXCEPTION
 ALLOWING FOR GRAB BARS TO BE INSTALLED IN A VERTICAL
 POSITION.
 5) SHT. AE 502 - REAR WALL DETAIL. THE MAXIMUM HEIGHT
 OF THE SANITARY NAPKIN DISPOSAL OPERABLE PART SHALL BE
 LOCATED A MAXIMUM OF 48 INCHES ABOVE THE FINISH FLOOR
 PER FBC-ACCESS. SECS.308 & 309.SSHOW THIS ON THE
 DETAIL.
 6) SHT. AE 502 - TOILET FIXTURES AND ACCESSORIES DETAIL
 - THE PAPER TOWEL DISPENSER OUTLET FOR THE PAPER TOWELS
 SHALL BE LOCATED A MAXIMUM OF 48 INCHES ABOVE THE
 FINISH FLOOR. THE DETAIL SHOWS THE PAPER TOWEL OUTLET
 ABOVE THIS MAXIMUM HEIGHT. FBC -ACCESS. SECS.308 & 309.
 7) SHT. AE 502 - GENERAL SHEET NOTES #4,5, & 6 REFER TO
 THE ANSI A117.1 & THE ADA. THE GOVERNING STANDARD FOR
 HANDICAP ACCESSIBILITY IN THE STATE OF FLORIDA IS THE
 FLORIDA BUILDING CODE - ACCESSIBILITY VOLUME. EITHER
 REVISE THE NOTES TO REFLECT THE FBC OR DELETE THE
 NOTES.
 8) SHT. AE 701 - INTERIORS- ROOM FINISH SCHEDULE SHOWS
 THE WALLS IN THE TOILET ROOM # 526 AS PAINT. WALLS AND
 PARTITIONS WITHIN TWO FEET OF WATER CLOSETS SHALL HAVE
 A SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OFF
 NOT LESS THAN 4 FEET ABOVE THE FLOOR,AND THE MATERIALS
 USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT
 ADVERSELY AFFECTED BY MOISTURE PER FBC-BUILDING SEC.
 1210.2.2. EPOXY PAINT DOES NOT MEET THE INTENT OF THIS
 CODE SECTION.
 9) SUBMIT FIRESTOPPING DETAILS FOR ANY PIPE
 PENETRATIONS THROUGH RATED FLOOR AND WALL ASSEMBLIES
 PER FBC -BUILDING SECS. 714.3 & 714.4.
 10) SHT. P002 - PLUMBING SPECIFICATIONS - (C) - PIPE &
 FITTINGS (2) - DOMESTIC WATER NOTE # ( B) - PVC IS NOT
 PERMITTED INSIDE THE BUILDING OR WATER DISTRIBUTION PER
 FBC-PLUMBING SEC.605.4 AND TABLE 605.4.
 11) TEMPERED WATER IS REQUIREED AT THE LAVATORY IN THE
 ACCESSIBLE TOILET ROOM PER FBC-PLUMBING SEC.416.5. THE
 WATER- TEMPERATURE LIMITING DEVICE SHALL COMPLY WITH
 ASSE 1070OR CSA B125.33.
 12) SHUTOFF VALVES ARE REQUIRED ON THE WATER SSUPPLY
 DROPS TO THE TOILET RROOM, BREAK ROOM SINK AND THE SINK
 IN THE WORK AREA.FBC-PLUMBING SEC.606.1, 06.2..
 13) THE BRANCH VENT FOR THE PLUMBING FIXTURES APPEARS
 TO XCEED 40 FET IN DEVELOPED LENGTH. VENNTS EXCEEDING
 40 FEET IN DEVELOPED LENGTH SHALL B INCREASED BY ONE
 NOMINAL PIPE SIZE OR THE ENNTIRE DEVELOPED LENGTH OF
 THHE VVENT PIPE PER FBC-PLUMBING SEC.906.2.
 14) SHT. P101 - KEYNOTE #1 - CALLS OUT AN 1 1/2 INCH
 COLD WATER LINE BUT THERE IS NO SUCH SIZED WATER LLINE
 SHOWN ON SHT. P901.
 15) PLANS SHALL DIGITALLY SIGNED AND SEALED PER FL.
 ADMIN. CODE RULE 61G1-16.005, 61G15-23.004,
 61G15-23.005.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-03-03 Cont ID  
Sent By medwards Date 2021-03-03 Time 09:10 Rev Time 0.00
Received By medwards Date 2021-03-03 Time 09:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-03-01 Cont ID  
Sent By tklarge Date 2021-03-01 Time 09:02 Rev Time 0.00
Received By tklarge Date 2021-03-01 Time 09:02 Sent To  
Notes
2021-03-01 09:06:46THE FOLLOWING SHEETS ARE NOT DIGITALLY SIGNED AND
 SEALED:
 THE COVER SHEET, "G" SHEETS, AD101, AE101, AE102,
 AE501, M001, M105, MD105, P003, PD101, FP001, FP101,
 E001, E002, ED205, E105, E305.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-01-21 Cont ID  
Sent By tklarge Date 2021-01-21 Time 07:53 Rev Time 0.00
Received By tklarge Date 2021-01-21 Time 07:52 Sent To  
Notes
2021-01-21 07:44:03PLANS DO NOT BEAR DIGITAL SIGNATURE OR SEAL.PER FL.
 ADMIN. CODE RULE 61G1--16.005, 61G15-23.004,
 61G15-23.005. T.LARGE.

Review Stop Z ZONING
Rev No 2 Status P Date 2021-02-16 Cont ID  
Sent By awooten Date 2021-02-16 Time   Rev Time 0.00
Received By awooten Date 2021-02-16 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-01-07 Cont ID  
Sent By awooten Date 2021-01-07 Time   Rev Time  
Received By awooten Date 2021-01-07 Time   Sent To  
Notes
***NONE***