Plan Review Stops For Permit 20120810 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-07-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-07-26 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-07-26 |
Time |
16:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-02-17 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-02-17 |
Time |
13:39 |
Sent To |
|
|
Notes |
2021-02-17 13:50:01 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: FAILED, SAME COMMENTS AS | | REVIEW #1. | | | | 1) DRAWINGS SHOW THREE A/C UNITS, BUT PANEL SCHEDULE | | ONLY SHOWS ONE UNIT. PLEASE CLARIFY AND CORRECT. FBC | | 107 | | 2) AHU SPECS INDICATE A10KW HEATER, BUT LOAD | | CALCULATIONS AND PANEL SCHEDULE SHOW AN 8.6 KW LOAD. | | PLEASE CLARIFY AND CORRECT. FBC 107 | | 3) PLEASE INDICATE CIRCUIT NUMBERS FOR ALL A/C | | EQUIPMENT ON POWER PLANS AND MATCH THEM TO PANEL | | SCHEDULE. FBC 107 | | 4) REVISION #3 INCLUDES THREE PIECES OF EQUIPMENT (H#1, | | H#2, AND H#3). PLEASE CLARIFY WHAT THEY ARE AND INCLUDE | | THEM ON YOUR SYMBOLS OR NOTES. IF PART OF THE A/C | | UNITS, PLEASE INDICATE CIRCUITS FEEDING THEM AND | | INCLUDE ON PANEL SCHEDULE. FBC 107 | | 5) A GFI, WP RECEPTABLE BE REQUIRED ON BACK OF UNIT. | | NEC 210.52 | | 6) PLEASE SEE SIGNATURE COMMENTS | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-12-17 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-12-17 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-12-17 |
Time |
08:06 |
Sent To |
|
|
Notes |
2020-12-17 14:31:52 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: FAILED, SEE COMMENTS BELOW. | | | | 1) DRAWINGS SHOW THREE A/C UNITS, BUT PANEL SCHEDULE | | ONLY SHOWS ONE UNIT. PLEASE CLARIFY AND CORRECT. FBC | | 107 | | 2) AHU SPECS INDICATE A10KW HEATER, BUT LOAD | | CALCULATIONS AND PANEL SCHEDULE SHOW AN 8.6 KW LOAD. | | PLEASE CLARIFY AND CORRECT. FBC 107 | | 3) PLEASE INDICATE CIRCUIT NUMBERS FOR ALL A/C | | EQUIPMENT ON POWER PLANS AND MATCH THEM TO PANEL | | SCHEDULE. FBC 107 | | 4) REVISION #3 INCLUDES THREE PIECES OF EQUIPMENT (H#1, | | H#2, AND H#3). PLEASE CLARIFY WHAT THEY ARE AND INCLUDE | | THEM ON YOUR SYMBOLS OR NOTES. IF PART OF THE A/C | | UNITS, PLEASE INDICATE CIRCUITS FEEDING THEM AND | | INCLUDE ON PANEL SCHEDULE. FBC 107 | | 5) A GFI, WP RECEPTABLE BE REQUIRED ON BACK OF UNIT. | | NEC 210.52 | | 6) PLEASE SEE SIGNATURE COMMENTS | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-08-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-19 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-19 |
Time |
11:30 |
Sent To |
|
|
Notes |
2021-08-19 10:52:28 | A/C SUB PERMIT 21080976 ISSUED. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-07-30 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-07-30 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-07-20 |
Time |
09:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-02-17 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-02-09 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-01-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-01-06 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-10-28 |
Time |
18:12 |
Sent To |
I |
|
Notes |
2020-12-16 18:13:07 | 12/16/2020 THIS A/C REVISION WAS SUBMITTED TOGETHER | | WITH POOL PERMIT 20080561 ON 10/28/2020. A/C REVISION | | WAS NOT REVIEWED. CREATED NEW REVISION NUMBER FOR | | PROPER REVIEW AND TRACKING. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2021-08-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-19 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-19 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2021-07-30 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-07-30 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-07-30 |
Time |
08:51 |
Sent To |
|
|
Notes |
2021-07-30 08:55:06 | MR. EDUARDO HERNANDEZ HAS SUBMITTED BOTH THE MECHANICAL | | EQUIPMENT SIZING CALCULATIONS AND THE MECHANICAL | | DRAWING BUT A MECHANICAL SUB PERMIT HAS NEVER BEEN | | PULLED FOR THIS PROJECT. WITHOUT A MECHANICAL SUB | | PERMIT I CAN NOT VERIFY HE IS THE MECHANICAL CONTRACTOR | | THAT HOLDS THE PERMIT TO INSTALL THE SYSTEMS FOR THIS | | PROJECT. PLEASE SUBMIT A MECHANICAL SUB PERMIT. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-02-17 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-02-17 |
Time |
09:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-12-17 |
|
|
Cont ID |
|
Sent By |
RMCDOUGA |
Date |
2020-12-17 |
Time |
07:07 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-12-17 |
Time |
07:07 |
Sent To |
|
|
Notes |
2020-12-17 07:07:31 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20120810 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS FOR THE NE MINI SPLITS. FBC EC R403.7.1 | | | | 2) PLEASE SHOW HOW THE CONDENSING UNITS WILL BE | | ANCHORED. FBC RES M1307.2 | | | | 3) PLEASE SHOW THE CONDENSATION DRAIN AND THE | | TERMINATION POINT. FBC RES M1411.3 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-07-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-07-26 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-07-26 |
Time |
13:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-12-17 |
|
|
Cont ID |
|
Sent By |
LCRESPO |
Date |
2020-12-17 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-12-17 |
Time |
13:22 |
Sent To |
|
|
Notes |
2020-12-17 13:39:24 | 12/17/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-07-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-07-26 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-07-26 |
Time |
13:42 |
Sent To |
|
|
Notes |
2021-07-26 13:43:23 | SHEET 9.0 WITH ENGINEER'S ORIGINAL SEAL/SIGNATURE. | | SENT TO STORAGE. JG. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-02-17 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-02-17 |
Time |
10:01 |
Sent To |
|
|
Notes |
2021-02-17 10:03:47 | SHEET 9: THE DESIGNER MUST DIGITALLY SIGN AND SEAL THE | | DOCUMENTS OR YOU MAY SIGN AND SEAL THE ORIGINAL PAPER | | DOCUMENT AND SUBMIT IT TO OUR OFFICE. | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-12-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-12-17 |
Time |
07:08 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-12-17 |
Time |
07:08 |
Sent To |
|
|
Notes |
2020-12-17 07:09:26 | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-01-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-01-06 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-01-06 |
Time |
10:00 |
Sent To |
|
|
Notes |
2021-01-06 10:01:59 | APPROVED BY ANGELA JONES-VANN ON 12/22/2020. JG. |
|
|