Plan Review Details - Permit 20120647
Plan Review Stops For Permit 20120647
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-01-06 Cont ID  
Sent By cpuell Date 2021-01-06 Time 16:37 Rev Time 0.00
Received By cpuell Date 2021-01-06 Time 16:37 Sent To  
Notes
2021-01-06 16:38:13115 1/2 WESTMINSTER RD CHANGED TO 117 WESTMINSTER RD

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-01-03 Cont ID  
Sent By cpuell Date 2021-01-03 Time 12:50 Rev Time 0.00
Received By cpuell Date 2021-01-03 Time 12:50 Sent To  
Notes
2021-01-03 12:50:371/2 ADDRESSES NO LONGER ALLOWED IN THE CITY PLEASE
 EMAIL [email protected] TO BE GIVEN AN ADDRESS FOR BACK
 UNIT

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-05-24 Cont ID  
Sent By rmcphers Date 2021-05-24 Time 13:03 Rev Time 0.00
Received By rmcphers Date 2021-05-24 Time 13:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-04-15 Cont ID  
Sent By rmcphers Date 2021-04-15 Time 08:17 Rev Time 0.00
Received By rmcphers Date 2021-04-15 Time 08:17 Sent To  
Notes
2021-04-15 08:27:08GUEST HOUSE REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 REVISED DRAWINGS
 1) PLEASE SHOW THE WOOD SHINGLE ATTACHMENTS FOR WIND
 ZONE 5 WHICH IS A HIGHER WIND PRESSURE THEN FBC
 R703.6.3 ATTACHMENT.
 WOOD SHAKES OR SHINGLES SHALL BE INSTALLED ACCORDING TO
 THIS CHAPTER AND THE MANUFACTURER?S INSTRUCTIONS. WHERE
 WIND PRESSURES DETERMINED IN ACCORDANCE WITH TABLE
 R301.2(2) DO NOT EXCEED 30 PSF.
 2) WINDOW SCHEDULE SHOWS A PRODUCT APPROVAL NUMBER
 (17-0918.11) WHICH IS NOT PROVIDED - PLEASE REVISE THE
 WINDOW SCHEDULE TO SHOW THE PRODUCT APPROVAL NUMBERS
 PROVIDED.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-01-21 Cont ID  
Sent By rmcphers Date 2021-01-21 Time 08:18 Rev Time 0.00
Received By rmcphers Date 2021-01-21 Time 08:18 Sent To  
Notes
2021-01-21 08:19:30DEFERRED - WINDOW/DOOR/SIDING PRODUCT APPROVALS

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-12-22 Cont ID  
Sent By rmcphers Date 2020-12-22 Time 13:29 Rev Time 0.00
Received By rmcphers Date 2020-12-22 Time 12:26 Sent To  
Notes
2020-12-22 13:26:08REMODEL GUESTHOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) SIDING IS SUBJECT TO WIND LOADS - PLEASE SHOW SIDING
 ATTACHMENTS OR PROVIDE A PRODUCT APPROVAL FOR THE
 SIDING - FBC R703.1.2
 2) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE NEW EXTERIOR DOORS (SWING
 DOORS AND OVERHEAD GARAGE DOOR) - ALL PRODUCT APPROVALS
 NEED TO BE REVIEWED AND MARKED APPROVED BY THE BUILDING
 DESIGNER OF RECORD.
 3) SIDING DETAILS AND WINDOW AND DOOR PRODUCT APPROVALS
 MAY BE DEFERRED SUBMITTALS BY LISTING ITEMS TO BE
 DEFERRED - 107.3.4.1 DEFERRED SUBMITTALS. FOR THE
 PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
 TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY
 SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE
 BUILDING OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL
 IN RESPONSIBLE CHARGE SHALL LIST THE DEFERRED
 SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED
 SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE
 BUILDING OFFICIAL.
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2021-06-02 Cont ID  
Sent By jleahy Date 2021-06-02 Time 10:28 Rev Time 0.00
Received By jleahy Date 2021-06-02 Time 10:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2021-06-01 Cont ID  
Sent By jleahy Date 2021-06-01 Time 08:36 Rev Time 0.00
Received By jleahy Date 2021-06-01 Time 08:29 Sent To  
Notes
2021-06-01 08:43:55ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PANEL "B" NEEDS TO HAVE A MAIN BREAKER, THERE ARE MORE
 THAN 6 CIRCUITS SO A MAIN IS REQUIRED
  
 230.71 MAXIMUM NUMBER OF DISCONNECTS. (A) GENERAL. THE
 SERVICE DISCONNECTING MEANS FOR EACH SERVICE PERMITTED
 BY 230.2, OR FOR EACH SET OF SERVICE-ENTRANCE
 CONDUCTORS PERMITTED BY 230.40, EXCEPTION NO. 1, 3, 4,
 OR 5, SHALL CONSIST OF NOT MORE THAN SIX SWITCHES OR
 SETS OF CIRCUIT BREAKERS, OR A COMBINATION OF NOT MORE
 THAN SIX SWITCHES AND SETS OF CIRCUIT BREAKERS, MOUNTED
 IN A SINGLE ENCLOSURE, IN A GROUP OF SEPARATE
 ENCLOSURES, OR IN OR ON A SWITCHBOARD OR IN SWITCHGEAR.
 THERE SHALL BE NOT MORE THAN SIX SETS OF DISCONNECTS
 PER SERVICE GROUPED IN ANY ONE LOCATION.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-01-20 Cont ID  
Sent By cthroop Date 2021-01-20 Time 15:25 Rev Time 0.00
Received By cthroop Date 2021-01-20 Time 14:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-12-18 Cont ID  
Sent By cthroop Date 2020-12-18 Time 09:20 Rev Time 0.00
Received By cthroop Date 2020-12-18 Time 07:36 Sent To  
Notes
2020-12-18 09:42:19PLAN REVIEW / ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2014 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. NEW EMERGENCY PANEL AND SUB PANEL SHOWN IN PANEL
 SCHEDULE. PROVIDE A NEW ELECTRICAL RISER DIAGRAHM.
 INCLUDE GROUNDING ELECTRODE SYSTEM.
 PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF SERVICE
 EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, WIRE AND
 BREAKER SIZES FOR SERVICE AND FEED TO ANY SUB-PANEL(S).
 SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING
 TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94,
 408.30; FBC RE E3706.1, E3608.1, E3609.3; WPB FBC
 107.2.1
  
 2. PANEL SCHEDULE SUBMITTED FOR REVIEW DOES NOT INCLUDE
 NEW RANGE AND HOOD CIRCUTS AND GAS W/H IGNITER CIRCUT.
 ALSO PROVIDE THE CONDUCTOR TYPE, WIRE SIZE AND V.A. OF
 EACH CIRCUT.
 PANEL SCHEDULE:
 PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902.
  
 3. LOAD CALC'S SUBMITTED FOR REVIEW DO NOT INCLUDE THE
 POOL EQUIPMENT, NEW SUB PANEL AND NEW EMERGENCY PANEL.
 PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING
 AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS
 ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
  
 4. R404.1LIGHTING EQUIPMENT (MANDATORY).
 NOT LESS THAN 75 PERCENT OF THE LAMPS IN PERMANENTLY
 INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY
 LAMPS OR NOT LESS THAN 75 PERCENT OF THE PERMANENTLY
 INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY
 HIGH-EFFICACY LAMPS.
 EXCEPTION: LOW-VOLTAGE LIGHTING.
 A NOTE ON THE PLAN WILL SUFFICE. FBC EC R404.1
  
 5. PROVIDE OUTLET AT FRONT OF STRUCTURE.
 E3901.7 OUTDOOR OUTLETS.
 NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY
 ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6
 FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE
 INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH
 DWELLING UNIT HAVING DIRECT ACCESS TO GRADE LEVEL.
  
 6. AN OUTLET IS REQUIRED ON THE SIDE OF THE NEW CLOSET
 IN THE FAMILY ROOM.
 E3901.2.2 WALL SPACE.
 AS USED IN THIS SECTION, A WALL SPACE SHALL INCLUDE THE
 FOLLOWING: [210.52(A)(2)]
 1.ANY SPACE THAT IS 2 FEET (610 MM) OR MORE IN WIDTH,
 INCLUDING SPACE MEASURED AROUND CORNERS, AND THAT IS
 UNBROKEN ALONG THE FLOOR LINE BY DOORWAYS AND SIMILAR
 OPENINGS, FIREPLACES, AND FIXED CABINETS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2020-12-18 Cont ID  
Sent By cthroop Date 2020-12-18 Time 09:20 Rev Time 0.00
Received By cthroop Date 2020-12-18 Time 08:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2020-12-17 Cont ID  
Sent By pleduc Date 2020-12-17 Time   Rev Time 0.00
Received By pleduc Date 2020-12-17 Time 13:11 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-12-18 Cont ID  
Sent By lcrespo Date 2020-12-18 Time 13:42 Rev Time 0.00
Received By lcrespo Date 2020-12-18 Time 13:42 Sent To  
Notes
2020-12-18 13:43:11GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A LICENSED CONTRACTOR MUST REQUIRE A SUB GAS PERMIT FOR
 THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2021-04-30 Cont ID  
Sent By aborngra Date 2021-04-30 Time 14:24 Rev Time 0.00
Received By aborngra Date 2021-04-22 Time 15:11 Sent To  
Notes
2021-04-30 14:24:22THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITION(S):
 1. ALL WINDOWS AND DOORS SHALL USE AN EXTERNAL
 DIMENSIONAL MUNTIN PROFILE. FOR CGI PRODUCTS THIS IS
 THE SEMI-CONTOURED PROFILE. FOR PGT PRODUCTS THIS IS A
 RAISED/PYRAMID PROFILE.
 2. ALL WINDOWS SHALL BE INSTALLED SO THAT THE WINDOW
 CASING DOES NOT EXTEND BEYOND THE WOOD STRUCTURAL
 FRAMING.
 3. THE WOOD SHINGLES SHALL BE CEDAR, CYPRESS, OR
 RECLAIMED PINE.
  
 AARON BORNGRABER, AICP
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2021-01-26 Cont ID  
Sent By aborngra Date 2021-01-26 Time 10:03 Rev Time 0.00
Received By aborngra Date 2021-01-26 Time 10:03 Sent To  
Notes
2021-01-26 10:03:47THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. PROVIDE A PHOTO OF THE EXISTING DOORS TO BE REPLACED
 AND A GRAPHIC OF THE PROPOSED DOORS.
 2. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE
 WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF
 AT [email protected] TO REQUEST THE EXAMPLE. AT
 MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND
 THE PROPOSED WINDOWS EXTERIOR FRAME COLOR, GLASS
 GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION
 WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW
 MARKED.
 3. PROVIDE A PHOTO OF THE EXISTING GARAGE DOOR AND A
 GRAPHIC OF THE PROPOSED GARAGE DOOR.
 4. PROVIDE PHOTOS OF THE EXISTING ELEVATIONS. THIS CAN
 BE COMBINED WITH THE REST OF THE EXISTING PHOTOS.
 5. PARTIALLY REMOVE THE EXISTING NON-HISTORIC SIDING TO
 ILLUSTRATE IF WOOD SIDING REMAINS OR NOT. IF WOOD
 SIDING IS EXISTING, DOCUMENT ITS CONDITION. TO USE
 HARDIEBOARD (SMOOTH ONLY), PROVIDE PHOTOS AND
 DOCUMENTATION THAT ILLUSTRATE THE EXISTING WOOD SIDING
 IS DAMAGED BEYOND REPAIR AND MEASURE THE WIDTH OF EACH
 PANEL AND THE PROFILE. THE HARDIEBOARD WILL NEED TO
 MATCH THE EXISTING WOOD SIDING. STAFF STRONGLY
 ENCOURAGES RESTORATION OF EXISTING WOOD SIDING.
 HISTORIC PRESERVATION BOARD WILL BE REQUIRED IF WOOD
 SIDING IS EXISTING FOR HARDIEBOARD SMOOTH INSTALLATION.
 6. ILLUSTRATE THE WIDTH OF EACH HARDIEBOARD PANEL AND
 PROFILE TO BE USED.
 7. ENSURE THE FLOOR PLAN AND WINDOW SCHEDULE MATCH. THE
 WINDOW SCHEDULE INDICATES ALL SINGLE-HUNG. THE FLOOR
 PLAN INDICATES A FEW LOCATIONS WITH A CASEMENT.
 8. HISTORIC DOES NOT ACCEPT DEFERRED PRODUCT APPROVALS.
 SUBMIT PRODUCT APPROVALS.
 ADDITIONAL COMMENTS MAY EXIST ONCE ADDITIONAL
 INFORMATION IS PROVIDED.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2020-12-30 Cont ID  
Sent By aborngra Date 2020-12-30 Time 14:25 Rev Time 0.00
Received By aborngra Date 2020-12-30 Time 14:25 Sent To  
Notes
2020-12-30 14:25:35THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. PROVIDE A PHOTO OF THE EXISTING DOORS TO BE REPLACED
 AND A GRAPHIC OF THE PROPOSED DOORS.
 2. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE
 WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF
 AT [email protected] TO REQUEST THE EXAMPLE. AT
 MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND
 THE PROPOSED WINDOWS EXTERIOR FRAME COLOR, GLASS
 GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION
 WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW
 MARKED.
 3. PROVIDE A PHOTO OF THE EXISTING GARAGE DOOR AND A
 GRAPHIC OF THE PROPOSED GARAGE DOOR.
 4. PROVIDE PHOTOS OF THE EXISTING ELEVATIONS. THIS CAN
 BE COMBINED WITH THE REST OF THE EXISTING PHOTOS.
 5. PARTIALLY REMOVE THE EXISTING NON-HISTORIC SIDING TO
 ILLUSTRATE IF WOOD SIDING REMAINS OR NOT. IF WOOD
 SIDING IS EXISTING, DOCUMENT ITS CONDITION. TO USE
 HARDIEBOARD (SMOOTH ONLY), PROVIDE PHOTOS AND
 DOCUMENTATION THAT ILLUSTRATE THE EXISTING WOOD SIDING
 IS DAMAGED BEYOND REPAIR AND MEASURE THE WIDTH OF EACH
 PANEL AND THE PROFILE. THE HARDIEBOARD WILL NEED TO
 MATCH THE EXISTING WOOD SIDING. STAFF STRONGLY
 ENCOURAGES RESTORATION OF EXISTING WOOD SIDING.
 HISTORIC PRESERVATION BOARD APPROVAL MAY BE REQUIRED
 FOR HARDIEBOARD SMOOTH INSTALLATION.
 6. ILLUSTRATE THE WIDTH OF EACH HARDIEBOARD PANEL AND
 PROFILE TO BE USED.
 7. THE CURRENT GARAGE PARKING SPACE IS TWO PARKING
 SPACES. THIS PROPERTY REQUIRES A TOTAL OF THREE PARKING
 SPACE. ILLUSTRATE THAT AT LEAST THREE PARKING SPACES,
 EACH 8.5 FEET X 18 FEET ARE AVAILABLE ON THE PROPERTY.
 8. ENSURE THE FLOOR PLAN AND WINDOW SCHEDULE MATCH. THE
 WINDOW SCHEDULE INDICATES ALL SINGLE-HUNG. THE FLOOR
 PLAN INDICATES A FEW LOCATIONS WITH A CASEMENT.
 ADDITIONAL COMMENTS MAY EXIST ONCE ADDITIONAL
 INFORMATION IS PROVIDED.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-06-02 Cont ID  
Sent By rmcphers Date 2021-06-02 Time 09:01 Rev Time 0.00
Received By rmcphers Date 2021-05-27 Time 11:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-05-24 Cont ID  
Sent By rmcphers Date 2021-05-24 Time 13:05 Rev Time 0.00
Received By rmcphers Date 2021-05-11 Time 06:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-05-01 Cont ID  
Sent By cpuell Date 2021-05-01 Time 15:58 Rev Time 0.00
Received By cpuell Date 2021-04-13 Time 10:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-26 Cont ID  
Sent By lmarchan Date 2021-01-26 Time 10:12 Rev Time 0.00
Received By lmarchan Date 2021-01-14 Time 10:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-03 Cont ID  
Sent By cpuell Date 2021-01-03 Time 12:47 Rev Time 0.00
Received By cpuell Date 2020-12-16 Time 14:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-06-02 Cont ID  
Sent By medwards Date 2021-06-02 Time 06:32 Rev Time 0.00
Received By medwards Date 2021-06-02 Time 06:32 Sent To  
Notes
2021-06-02 06:32:57 
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By medwards Date 2021-01-19 Time 07:14 Rev Time 0.00
Received By medwards Date 2021-01-19 Time 07:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-12-18 Cont ID  
Sent By medwards Date 2020-12-18 Time 10:07 Rev Time 0.00
Received By medwards Date 2020-12-18 Time 10:07 Sent To  
Notes
2020-12-18 10:07:541ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20120647
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW THE RETURN AIR PATH FROM THE BEDROOM
 BACK TO THE AHU. THERE IS A 12 X 12 R/A GRILL IN THE
 BEDROOM BUT I DO NOT SEE ANY DUCTWORK ATTACHING IT TO
 THE RETURN IN THE FAMILY ROOM. FBC RES M1602.3
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-06-02 Cont ID  
Sent By lcrespo Date 2021-06-02 Time 08:08 Rev Time 0.00
Received By lcrespo Date 2021-06-02 Time 08:08 Sent To  
Notes
2021-06-02 08:08:5106/02/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By lcrespo Date 2021-01-19 Time 10:59 Rev Time 0.00
Received By lcrespo Date 2021-01-19 Time 10:59 Sent To  
Notes
2021-01-19 11:05:1101/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-12-18 Cont ID  
Sent By lcrespo Date 2020-12-18 Time 09:34 Rev Time 0.00
Received By lcrespo Date 2020-12-18 Time 07:55 Sent To  
Notes
2020-12-18 09:35:3212/18/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE PROVIDE ON PLUMBING ISOMETRIC RISER DIAGRAM
 WHERE THE WASHING MACHINE WILL BE CONNECTED TO, IF IT
 IS TO THE OUTSIDE, IT WILL NEED TO BE A VENT TO THE
 OUTSIDE, IF IT IS TO THE EXISTING SYSTEM INSIDE ( AN
 AIR ADMITTANCE VALVE MAY BE USED). THE TWO DRAINAGE
 LINES, KS AND W/M, ARE NOT SIZED FOR THE HORIZONTAL
 DRAIN ( W/M REQUIRES A 3? STACK PER MOST MANUFACTURERS
 SPECIFICATION AND PLUMBING CODE 2017 FBC SEC. P 406.2
 WASTE CONNECTION).
  
 NOTE: FOR THE NEW PLUMBING INFORMATION PROVIDE, THIS
 MAY CHANGE WHEN DUE TO STRUCTURE. THESE CHANGES CAN BE
 REVISED BEFORE FINAL PLUMBING PER THE WPB AMENDMENTS TO
 THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL PLUMBING.
  
 2. A LICENSED CONTRACTOR MUST REQUIRE A SUB PLUMBING
 PERMIT FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO
 THE FBC SEC. 105.1.
  
 3. THESE ARE MULTI-FAMILY DWELLINGS, AND THE WATER
 USERS WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION
 ASSEMBLY AT THE POINT OF DELIVERY. THE TYPE OF BACKFLOW
 ASSEMBLY REQUIRED WILL BE DEPENDENT UPON THE DEGREE OF
 HAZARD POSED BY THE WATER USER. A REDUCED PRESSURE ZONE
 BACKFLOW DEVICE WILL BE REQUIRED AT THE WATER METER PER
 THE CITY OF WEST PALM CROSS UTILITIES DEPARTMENT AND
 THEIR CONNECTION CONTROL PROGRAM.
  
 4. ON SHEET A-1, IT SAYS THE WATER HEATER IS EXISTING,
 AND IT IS GOING TO BE REPLACED WITH A TANK-LESS. THERE
 IS NO INDICATION IF IT OR WAS ELECTRICAL OR GAS. ON
 SHEET E-1, THERE IS AN IN-STA HOT IGNITOR, SO IS THIS
 FOR THE KITCHEN SINK OR THE SOURCE OF HEATING THE
 WATER? PLEASE CLARIFY.
  
 5. THE SHEET MP-1 SHOWS A GAS TANK-LESS WATER HEATER
 THAT MAY CLARIFY THE COMMENT ABOVE, BUT IT SAYS
 EXISTING GAS TANK WATER HEATER. THE CITY OF WEST PALM
 BEACH HAS NO RECORD OF A GAS PERMIT FOR THIS STRUCTURE,
 AND THE CITY OF WEST PALM BEACH WILL NEED A FULL GAS
 EVALUATION ALONG WITH A SUB GAS PERMIT WILL BE REQUIRED
 AT OWNER EXPENSE. YOU MAY HAVE A GAS REVIEW DONE AT
 THIS TIME FOR THE SUB GAS PERMIT, BUT ALL INFORMATION
 HAS TO BE SUBMITTED FOR A REVIEW. YOU MAY CHOOSE TO DO
 A REVIEW FOR THE GAS LATER BY A LICENSED CONTRACTOR, SO
 PLACE A NOTE ON THE PLANS, PLEASE.
  
 NOTE: GAS UNIT VENTING AND PLACEMENT TO DOORS OR
 WINDOWS MAY WORK BETTER OUTSIDE THE STRUCTURE.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status P Date 2021-06-02 Cont ID  
Sent By rmcphers Date 2021-06-02 Time 09:00 Rev Time 0.00
Received By rmcphers Date 2021-06-02 Time 09:00 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date 2021-05-24 Cont ID  
Sent By rmcphers Date 2021-05-24 Time 13:03 Rev Time 0.00
Received By rmcphers Date 2021-05-24 Time 13:03 Sent To  
Notes
2021-05-24 13:04:17USE OF PRIVATE PROVIDER FORM PROVIDED.
 1) PLEASE PROVIDE A QUALIFICATION STATEMENT/RESUME PER
 FS 553.791 (4) (B)
 2) PLEASE PROVIDE A CERTIFICATE OF INSURANCE PER FS
 553.791 (4) (B)
 3) PLEASE PROVIDE COPY OF INSPECTOR LICENSES PER FS
 553.791 (3)

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2021-04-15 Cont ID  
Sent By rmcphers Date 2021-04-15 Time 08:27 Rev Time 0.00
Received By rmcphers Date 2021-04-15 Time 08:27 Sent To  
Notes
2021-04-15 08:40:20USE OF PRIVATE PROVIDER FORM PROVIDED.
 1) PLEASE PROVIDE A QUALIFICATION STATEMENT/RESUME PER
 FS 553.791 (4) (B)
 2) PLEASE PROVIDE A CERTIFICATE OF INSURANCE PER FS
 553.791 (4) (B)
 3) PLEASE PROVIDE COPY OF INSPECTOR LICENSES PER FS
 553.791 (3)

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2021-06-02 Cont ID  
Sent By lcrespo Date 2021-06-02 Time 08:09 Rev Time 0.00
Received By lcrespo Date 2021-06-02 Time 08:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-05-24 Cont ID  
Sent By rmcphers Date 2021-05-24 Time 13:03 Rev Time 0.00
Received By rmcphers Date 2021-05-24 Time 13:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-04-15 Cont ID  
Sent By rmcphers Date 2021-04-15 Time 08:46 Rev Time 0.00
Received By rmcphers Date 2021-04-15 Time 08:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-01-19 Cont ID  
Sent By medwards Date 2021-01-19 Time 07:17 Rev Time 0.00
Received By medwards Date 2021-01-19 Time 07:17 Sent To  
Notes
2021-01-19 07:17:51PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-12-18 Cont ID  
Sent By cthroop Date 2020-12-18 Time 07:41 Rev Time 0.00
Received By cthroop Date 2020-12-18 Time 07:41 Sent To  
Notes
2020-12-18 07:42:09ALL PLAN PAGES VERIFIED. CT

Review Stop Z ZONING
Rev No 3 Status P Date 2021-04-30 Cont ID  
Sent By aborngra Date 2021-04-30 Time 14:24 Rev Time 0.00
Received By aborngra Date 2021-04-30 Time 14:23 Sent To  
Notes
2021-04-30 14:24:08THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITION(S):
 1. ALL WINDOWS AND DOORS SHALL USE AN EXTERNAL
 DIMENSIONAL MUNTIN PROFILE. FOR CGI PRODUCTS THIS IS
 THE SEMI-CONTOURED PROFILE. FOR PGT PRODUCTS THIS IS A
 RAISED/PYRAMID PROFILE.
 2. ALL WINDOWS SHALL BE INSTALLED SO THAT THE WINDOW
 CASING DOES NOT EXTEND BEYOND THE WOOD STRUCTURAL
 FRAMING.
 3. THE WOOD SHINGLES SHALL BE CEDAR, CYPRESS, OR
 RECLAIMED PINE.
  
 AARON BORNGRABER, AICP
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop Z ZONING
Rev No 2 Status F Date 2021-01-26 Cont ID  
Sent By aborngra Date 2021-01-26 Time 10:04 Rev Time 0.00
Received By aborngra Date 2021-01-26 Time 10:04 Sent To  
Notes
2021-01-26 10:04:05THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. PROVIDE A PHOTO OF THE EXISTING DOORS TO BE REPLACED
 AND A GRAPHIC OF THE PROPOSED DOORS.
 2. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE
 WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF
 AT [email protected] TO REQUEST THE EXAMPLE. AT
 MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND
 THE PROPOSED WINDOWS EXTERIOR FRAME COLOR, GLASS
 GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION
 WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW
 MARKED.
 3. PROVIDE A PHOTO OF THE EXISTING GARAGE DOOR AND A
 GRAPHIC OF THE PROPOSED GARAGE DOOR.
 4. PROVIDE PHOTOS OF THE EXISTING ELEVATIONS. THIS CAN
 BE COMBINED WITH THE REST OF THE EXISTING PHOTOS.
 5. PARTIALLY REMOVE THE EXISTING NON-HISTORIC SIDING TO
 ILLUSTRATE IF WOOD SIDING REMAINS OR NOT. IF WOOD
 SIDING IS EXISTING, DOCUMENT ITS CONDITION. TO USE
 HARDIEBOARD (SMOOTH ONLY), PROVIDE PHOTOS AND
 DOCUMENTATION THAT ILLUSTRATE THE EXISTING WOOD SIDING
 IS DAMAGED BEYOND REPAIR AND MEASURE THE WIDTH OF EACH
 PANEL AND THE PROFILE. THE HARDIEBOARD WILL NEED TO
 MATCH THE EXISTING WOOD SIDING. STAFF STRONGLY
 ENCOURAGES RESTORATION OF EXISTING WOOD SIDING.
 HISTORIC PRESERVATION BOARD WILL BE REQUIRED IF WOOD
 SIDING IS EXISTING FOR HARDIEBOARD SMOOTH INSTALLATION.
 6. ILLUSTRATE THE WIDTH OF EACH HARDIEBOARD PANEL AND
 PROFILE TO BE USED.
 7. ENSURE THE FLOOR PLAN AND WINDOW SCHEDULE MATCH. THE
 WINDOW SCHEDULE INDICATES ALL SINGLE-HUNG. THE FLOOR
 PLAN INDICATES A FEW LOCATIONS WITH A CASEMENT.
 8. HISTORIC DOES NOT ACCEPT DEFERRED PRODUCT APPROVALS.
 SUBMIT PRODUCT APPROVALS.
 ADDITIONAL COMMENTS MAY EXIST ONCE ADDITIONAL
 INFORMATION IS PROVIDED.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-12-30 Cont ID  
Sent By aborngra Date 2020-12-30 Time 14:36 Rev Time 0.00
Received By aborngra Date 2020-12-30 Time 14:35 Sent To  
Notes
2020-12-30 14:36:04THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. PROVIDE A PHOTO OF THE EXISTING DOORS TO BE REPLACED
 AND A GRAPHIC OF THE PROPOSED DOORS.
 2. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE
 WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF
 AT [email protected] TO REQUEST THE EXAMPLE. AT
 MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND
 THE PROPOSED WINDOWS EXTERIOR FRAME COLOR, GLASS
 GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION
 WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW
 MARKED.
 3. PROVIDE A PHOTO OF THE EXISTING GARAGE DOOR AND A
 GRAPHIC OF THE PROPOSED GARAGE DOOR.
 4. PROVIDE PHOTOS OF THE EXISTING ELEVATIONS. THIS CAN
 BE COMBINED WITH THE REST OF THE EXISTING PHOTOS.
 5. PARTIALLY REMOVE THE EXISTING NON-HISTORIC SIDING TO
 ILLUSTRATE IF WOOD SIDING REMAINS OR NOT. IF WOOD
 SIDING IS EXISTING, DOCUMENT ITS CONDITION. TO USE
 HARDIEBOARD (SMOOTH ONLY), PROVIDE PHOTOS AND
 DOCUMENTATION THAT ILLUSTRATE THE EXISTING WOOD SIDING
 IS DAMAGED BEYOND REPAIR AND MEASURE THE WIDTH OF EACH
 PANEL AND THE PROFILE. THE HARDIEBOARD WILL NEED TO
 MATCH THE EXISTING WOOD SIDING. STAFF STRONGLY
 ENCOURAGES RESTORATION OF EXISTING WOOD SIDING.
 HISTORIC PRESERVATION BOARD APPROVAL MAY BE REQUIRED
 FOR HARDIEBOARD SMOOTH INSTALLATION.
 6. ILLUSTRATE THE WIDTH OF EACH HARDIEBOARD PANEL AND
 PROFILE TO BE USED.
 7. THE CURRENT GARAGE PARKING SPACE IS TWO PARKING
 SPACES. THIS PROPERTY REQUIRES A TOTAL OF THREE PARKING
 SPACE. ILLUSTRATE THAT AT LEAST THREE PARKING SPACES,
 EACH 8.5 FEET X 18 FEET ARE AVAILABLE ON THE PROPERTY.
 8. ENSURE THE FLOOR PLAN AND WINDOW SCHEDULE MATCH. THE
 WINDOW SCHEDULE INDICATES ALL SINGLE-HUNG. THE FLOOR
 PLAN INDICATES A FEW LOCATIONS WITH A CASEMENT.
 ADDITIONAL COMMENTS MAY EXIST ONCE ADDITIONAL
 INFORMATION IS PROVIDED.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved